Sei sulla pagina 1di 25

Huawei RH2288 V3 Rack Server

Promotional Theme Slides

HUAWEI TECHNOLOGIES CO., LTD.


Contents

1 Click to addTrends
Rack Server Development Title

2 Click to add Title


RH2288 V3 Overview

3 Click to add Title


RH2288 V3 Highlights

4 RH2288 V3 Applications

www.huawei.com ▪ Huawei Confidential ▪ 1


Server Development Trends
RISC to x86 Virtualization Big data

High TCO for RISC Cloud computing Computing and storage


servers resource pooling of massive data

• RISC server migration to • Large memory capacity • Distributed architecture


x86 servers • Multiple threads and • Real-time in-memory
• Much more cost-effective computing cores computing
than RISC servers • Mission-critical application • Large local storage
• Easy to expand and virtualization capacity
upgrade

www.huawei.com ▪ Huawei Confidential ▪ 2


RISC Market Declines While x86 Market Rises
2009–2013 RISC server market trend
Shipments (units)
Power Itanium SPARC
150,000

100,000

50,000

0
2009 YR 2010 YR 2011 YR 2012 YR 2013 YR
Source: Gartner, 2013

RISC server market share: down from 45% in 2002 to 15%


Alibaba had over 130,000 PC servers by the end of 2013
in 2012
to support daily peak transactions of CNY35 billion and
Annual decrease rate of 17% from 2009 to 2013
distribution of 152 million packages.
Leading vendors sharply reduce investments in RISC servers.

www.huawei.com ▪ Huawei Confidential ▪ 3


Virtualization Requirements for Servers
Wide range of virtualization deployment Technical features

• Open, universal platform


• Large-capacity, cost-
effective memory
• Unified management of

Public cloud Workload optimization physical and virtual


machines
• High-speed network
interconnection
• Secure, reliable platform
Mission-critical Data center integration • High energy efficiency
enterprise applications

www.huawei.com ▪ Huawei Confidential ▪ 4


Big Data Analysis Acceleration
Big data hardware platform Big data applications

Concurrent execution of multi-


threaded applications Preventive Network
maintenance optimization

Addressing
Real-time in-memory computing service
requirements

Internal threat Product


Large local storage capacity real-time warning recommendation

High-performance SSD
acceleration Supply and
360° customer service
demand prediction

www.huawei.com ▪ Huawei Confidential ▪ 5


RH2288 V3: Foundation for Basic IT Services
Basic services Big data Virtualization Web
RH2288 V3
• Ideal for basic services: delivers excellent
performance, scalability, and flexibility, and is easy to
manage and maintain.
• Flexible expansion: supports six PCIe slots, super
large storage capacity, various LOM modules, and
high scalability to provide cost-effective configuration
on demand.

96 TB 6 1+1 Integrated
Large local storage Flexible PCIe I/O Internal redundant SATA Unified, convenient
capacity expansion cards DOM storage remote management

www.huawei.com ▪ Huawei Confidential ▪ 6


Contents

1 Click to addTrends
Rack Server Development Title

2 Click to add Title


RH2288 V3 Overview

3 Click to add Title


RH2288 V3 Highlights

4 RH2288 V3 Applications

www.huawei.com ▪ Huawei Confidential ▪ 7


RH2288 V3 Technical Specifications
Front view Form factor 2U 2-socket rack server
Number of
1 or 2
processors
Processor Intel Xeon E5-2600 v3 series processors
Memory 16 DDR4 DIMMs/LDIMMs
Appearance

•8 x 2.5-inch hard disks


•10 x 3.5-inch hard disks
Internal storage
•12 x 3.5-inch + 2/4 x 2.5-inch or 3.5-inch hard disks
•25 x 2.5-inch + 2/3 x 2.5-inch hard disks
Rear view
RAID 0, 1, 10, 5, 50, 6, and 60
RAID support
Optional supercapacitor
PCIe expansion Up to 6 PCIe slots
LOM network port 2 or 4 x GE ports, or 2 x 10GE ports
PSU Two hot-swappable PSUs in 1+1 redundancy mode
Fan module Efficient fan modules in N+1 redundancy mode
Operating
5°C–45°C
temperature
• Enhanced performance: supports two E5-2600 v3 series processors and uses the latest DDR4 memory technologies, delivering much higher
Highlights

computing performance than the previous platform.


• Super large storage capacity: supports up to 96 TB local storage capacity, ideal for distributed databases and big data analysis.
• Simplified maintenance: supports unified remote configuration over the GUI, and provides an LED diagnosis panel for information display.
• Huawei proprietary chipset: iBMC uses a Huawei HiSilicon chipset to meet customization requirements and to improve network security.

www.huawei.com ▪ Huawei Confidential ▪ 8


RH2288 V3 Internal Structure
CPU and Fan
heat sink modules

PCIe module

Hard disk
enclosure
RAID controller
card

Rear hard disk


enclosure

DIMM slots
PSU

www.huawei.com ▪ Huawei Confidential ▪ 9


RH2288 V3 Front View
User-friendly design
 Customer information labels for assets
management
 Various indicators
 Various ports

Optimal structure layout


 Indicators and ports are distributed on the
1 Fault diagnosis LED 2 Healthy indicator mounting ears on both sides instead of in the
middle, leaving sufficient space for hard disks.
3 UID button/indicator 4 Power button/indicator
 The double-faced cellular boards increase
5 VGA port 6 NMI button airflow input volume and improve cooling
7 Customer information label 8 Built-in DVD-ROM drive efficiency.
Diagnosis panel
Hard disks (numbered 0 to 7
9 10 Hard disk fault indicator
from left to right)
 Fault diagnosis LED
11 Hard disk active indicator 12 USB port
 Various colors indicating component status
13 Ethernet port indicator 4 14 Ethernet port indicator 3
15 Ethernet port indicator 2 16 Ethernet port indicator 1

www.huawei.com ▪ Huawei Confidential ▪ 10


RH2288 V3 Rear View
Expansion module
 Two expansion modules: optional PCIe
module or rear hard disk
 Up to six PCIe slots

PSU
 Two hot-swappable PSUs in 1+1
redundancy mode
1 PSU 2 PSU indicator  Highly efficient Platinum PSUs
3 Power socket of a PSU 4 I/O expansion module 2  HV DC PSUs

5
Connectivity status
6 Data transmission status indicator Rear ports
indicator
7 Onboard PCIe slot 8 I/O expansion module 1  Dedicated GE management network port
9 LOM 10 UID indicator for remote management over the GUI

11 USB 3.0 port 12 Management network port (Mgmt)  LOM module, supporting two or four GE
ports or two 10GE ports
13 VGA port 14 Serial port

www.huawei.com ▪ Huawei Confidential ▪ 11


RH2288 V3 Expansion Modules

Two expansion modules Optional expansion modules

 Hard disk expansion


module (two hard disks)

 PCIe module with


three PCIe slots

 PCIe module with


two PCIe slots

 Choose expansion modules based on service requirements, which improves


flexibility and maximizes ROI.

www.huawei.com ▪ Huawei Confidential ▪ 12


Contents

1 Click to addTrends
Rack Server Development Title

2 Click to add Title


RH2288 V3 Overview

3 Click to add Title


RH2288 V3 Highlights

4 RH2288 V3 Applications

www.huawei.com ▪ Huawei Confidential ▪ 13


High-Performance, Large- Large Easy Energy
Stability Security
capacity maintenance efficiency
Capacity Local Storage
Flexible configuration of super large storage capacity
Balance between capacity and performance

 Up to 96 TB storage capacity
per server (6 TB per disk) 12 x 3.5-inch 25 x 2.5-inch
 Over four hard disk hard disks hard disks
configuration schemes, meeting
2 x 3.5-inch
diverse application expansion hard
10 x 3.5-inch 8 x 2.5-inch
requirements hard disks hard disks disks

12 Gbit/s SAS high-performance solution


IOPS (K/s) Bandwidth (MB/s)
 End-to-end 12 Gbit/s SAS solution 1500 8000

with a controller and expander 6000


1000
6G SAS 4000 6G SAS
 82% higher IOPS performance 500 12G SAS 2000 12G SAS
 52% higher throughput bandwidth
0 0
6G SAS 12G SAS 6G SAS 12G SAS

www.huawei.com ▪ Huawei Confidential ▪ 14


Fault Diagnosis LED Large
capacity
Easy
maintenance
Energy
efficiency
Stability Security

Fault Code List


C01 Processor 1 is abnormal or faulty.
Processor
C02 Processor 2 is abnormal or faulty.
000 DIMM 000 is abnormal or faulty.
Memory
001 DIMM 001 is abnormal or faulty.
The air intake vent temperature is out of the
A00
operating temperature range of the server.
Temperature
The temperature of processor 1 is out of its
A01
operating temperature range.
P01 PSU 1 is abnormal or faulty.
PSU
Fault diagnosis LED P02 PSU 2 is abnormal or faulty.
F01 Fan module 1 is abnormal or faulty.
Fan module
Fault diagnosis LED F02 Fan module 2 is abnormal or faulty.
• Health status of the following components: b01
The DC-to-DC power module on the mainboard is
• Processors abnormal.
• Hard disks and DIMMs Mainboard b02 The RAID controller card is abnormal or faulty.
• PSUs L01 The cable is not securely or correctly connected.
• Mainboard E01 The CMOS battery is abnormal.
• Fan modules Hard disk
H01 The hard disk in slot 0 is abnormal or faulty.

• Air intake vent temperature H02 The hard disk in slot 1 is abnormal or faulty.

Convenient device maintenance and precision fault locating ensure stable server operating.

www.huawei.com ▪ Huawei Confidential ▪ 15


SDM Device Management Large Easy Energy
Stability Security
capacity maintenance efficiency
Solution
 Black box  Power capping
The black box function records fault information
The rack density increases by 60%.
instantly before server breakdown, which is similar to
 Intelligent power management
Reliable

a black box on an airplane.

Green
Dynamic PSU hibernation reduces power consumption by
 Video recording
up to 16%.
The KVM video recording function records system
running and exception information in real time.
 Real-time monitoring
The SDM monitors the ambient temperature and
 Untended management temperature of key components such as processors and
Device exceptions are reported to maintenance DIMMs in real time.
personnel by emails. The SDM monitors the fan speed in real time.

 IPMI 2.0  Seamless integration


Integrates with the iBMC module that complies with IPMI Huawei centralized management software eSight can
Intelligent

2.0 to monitor the server intelligently. integrate with the CA, OpenView, and System Center for

Open
 Web-based management unified management.

Supports web-based management UIs, without the need  Simplified management


to install management software. Independent 10/100/1000M BMC out-of-band management
 KVM over IP network port, supporting SOL

Supports virtual media to provide a remote virtual DVD  Remote maintenance


drive and FDD. Remote BIOS and firmware upgrades

www.huawei.com ▪ Huawei Confidential ▪ 16


SDM for Unified Management Large
capacity
Easy
maintenance
Energy
efficiency
Stability Security

Manager Management solution


HUAWEI Microsoft BMC Other third-party
iBMC and BMA support single-
eSight System Center Patrol managers
device in-band and out-of-band
management.
SNMP eSight supports centralized
IPMI management.
CLI… Open interfaces and various plug-
ins allow the SDM to be integrated
by third-party management
In-band agent Out-of-band controller
systems.
IPMI The SDM provides various
BMA BMC
functions, including configuration,
monitoring, diagnosis, and
performance analysis of server
Managed servers components.

www.huawei.com ▪ Huawei Confidential ▪ 17


High Energy Efficiency and Large Easy Energy
Stability Security
High Performance capacity maintenance efficiency

Energy-efficient and environment-friendly


 Ranked top in SPECpower testing.
 Passed international and national energy conversation certifications.
80Plus Titanium PSUs with over
Power capping DEMT
96% power efficiency
• Highly efficient Titanium PSUs • Increased utilization of the • Over 13% higher energy efficiency
• Energy-saving range covering idle
• Onboard DC/DC power efficiency equipment room and rack power
to 100% loads
of 96% supplies • Dynamic hibernation of processors
• 240 V/380 V HV DC PSUs • Increased device density in an and hard disks
equipment room and reduced • Dynamic, intelligent fan speed
adjustment based on the PID
rentals for equipment rooms algorithm
• 60% higher device density per rack • Active/standby power supplies

Load
Dynamic power capping
Energy-saving effects at various service loads

www.huawei.com ▪ Huawei Confidential ▪ 18


Stable, Reliable System Large Easy Energy
Stability Security
capacity maintenance efficiency
Design
Stable operating at 45°C (113°F) Shockproof design, reducing the Carrier-class components and derating
device failure rate design
Split-type shock
absorption stud
Polymer capacitors
Secondary
modeling
X7R capacitors required in thermal-sensitive
areas
Fan frame
Gold-plated connectors
Connector
support
Split-type shock absorption stud
Early failure Wear-out
Service life
Flexible
period failure period
pedestal
e Stress Related
Curve Failures
I
h
Wear-out
L
Failures
Quailty
Protection Failures
a) 2.5-inch disk enclosure gap

Note: Note:
1. Fan module shock isolation and hard disk tray 1. The RH2288 V3 uses Huawei carrier-class high-
shockproof design are used to avoid sensitive
Note: reliability components and certification process.
frequencies and to decrease risks of hard disk
performance deterioration caused by rotating or 2. Derating design makes electric and temperature
Optimal airflow design, efficient fan modules, and
shaking components. stress on components lower than the designed
PID-based fan speed adjustment allow the server to 2. Scientific packaging design effectively reduces the rated values, therefore delaying parameter
operate stably at 45°C, which is 10°C higher than impact of shocks incurred during transportation, degradation, prolonging the service life, and
ensuring device reliability.
other vendors' servers (10°C–35°C). increasing reliability.

Optimal system design enhances device reliability, ensuring the lowest failure rate.

www.huawei.com ▪ Huawei Confidential ▪ 19


RAS Enhancement Features Large
capacity
Easy
maintenance
Energy
efficiency
Stability Security

No. Type RAS Feature


1 System error recording
DIMM
The RH2288 V3 high-end 2-socket server isolation
2 Fault diagnosis
Isolation of faulty 3 System eMCA2 based on software and hardware
uses 27 RAS enhancement features to processors 4 architecture Isolation of faulty components
5 Predictive failure analysis (PFA)
improve system reliability, suiting 6 Enhanced SMM (eSMM)
applications that require high reliability. Memory
7 Isolation of memory pages, memory
blocks, and DIMMs
8 OS Online service migration
ECC 9 Online OS upgrades
10 Multiple copies of key code
DIMM ECC and automated PMI 11 DIMM ECC and automated PMI
PCIe fault SDDC Identification and isolation of failed
Memory mirroring 12 DIMMs
reporting PCIe devices 13 SDDC
Memory sparing
DDR4 address & command 14 Memory thermal throttling
parity retry
DIMM

DIMM
DIMM

DIMM
15 Device tagging

DIMM
16 Memory multi-rank sparing
17 Memory mirroring
18 DDR4 address & command parity retry
Processor Processor 19 Data scrambling
20 Core isolation configuration
DIMM
DIMM

DIMM
21 Socket isolation

DIMM
Processor Access from an out-of-band system to an
22 MCA register over the Platform
QPI CRC Environment Control Interface (PECI)
Processor core isolation Link-layer retransmission 23 IVR (core/socket voltage detection)
Processor power detection 24 PCIe advanced error reporting
upon errors 25
I/O
I/O multipath redundancy
26 QPI data packet CRC
QPI
27 Link-layer retransmission upon errors

www.huawei.com ▪ Huawei Confidential ▪ 20


Enhanced Security Large
capacity
Easy
maintenance
Energy
efficiency
Stability Security

Security design

• The front bezel in the server


chassis is locked to ensure hard
disk security and reliability.
Front bezel • The upper cover of the chassis is
locked to ensure the security of
internal components.
Locked
upper cover Unpacking • The system detects and records
and checking
Security design events for chassis cover opening.
• The system meets the security
requirements of Huawei.

The overall system security design enhances device and system security.

www.huawei.com ▪ Huawei Confidential ▪ 21


Contents

1 Click to addTrends
Rack Server Development Title

2 Click to add Title


RH2288 V3 Overview

3 Click to add Title


RH2288 V3 Highlights

4 RH2288 V3 Applications

www.huawei.com ▪ Huawei Confidential ▪ 22


The slides are used for early-stage promotion of the
RH2288 V3. Its success stories will be added later.

www.huawei.com ▪ Huawei Confidential ▪ 23


www.huawei.com

Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved.


All logos and images displayed in this document are the sole property of their respective copyright holders. No endorsement, partnership, or affiliation is suggested or implied. The
information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio,
new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive
statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time
without notice.

Potrebbero piacerti anche