Ship Piping Systems


H thng dn mn

Bilge System
Bilge System

Basic requirement is to provide effective drainage


to all dry spaces and at the same time prevent
water from entering the spaces through this
system.
Discharge of oily water from machinery spaces is
to comply with MARPOL Annex 1
Oily water is treated in an oily-water separator
before being allowed to be discharged.
Discharge water must be monitored with purity
not to exceed ppm set by MARPOL.
Bilge System
Bilge main diameter, dm
dm 1.68 L ( B D) 25 (mm)
L = length of ship
B = Breadth
D = Depth

Branch bilge main diameter, db

db 2.15 l ( B D) 25 (mm)

l = length of compartment
Bilge System
Bilge pump capacity, Q
2
dm
Q 5.75 3 (m3/h)
10

Two bilge pumps are required


Suctions are arranged such that water can be
pumped out when ship is inclined 5
Arrangement must be such that water cannot pass
from sea or ballast system into dry spaces through
the bilge system
Oily-water Separator
Ballast System

Ballast System
Ballast System
For safe operation, at least two ballast pumps are
to be connected to ballast tanks.
Stripping eductor can also be used for emptying
the bilges in cargo holds with 2 non-return valves
between hold and system
Ship side valve material must not of grey cast iron
and to direct mechanical manual operate
Air and Sounding Systems
Purposes
to secure ventilation of tanks, cofferdam and
tunnels to prevent over-pressurizing and vacuum
(air pipes)
to ascertain the level of liquid in tanks, cofferdam
and tunnels (Sounding pipes)
Vent pipes need to prevent flooding of spaces
through their upper ends
Vent pipes need to safely prevent flammable
liquids or vapours due to their fire hazards
Air and Sounding Systems
Machinery Spaces
Heavy fuel oil overflow tank has short self-closing
type sounding pipe
HFO overflow tank air pipe is led to open deck as
required.
Lubricating oil sump tank air pipe may end inside
machinery space but away from ignition sources
Air and Sounding Systems
Machinery Spaces
Air or overflow pipes internal are are normally
required to be 1.25 times the area of respective
filling pipes for a tank.
Velocity in the air pipe is not to exceed 4 m/s
when using one pump for one tank.
Air and Sounding Systems
Air and Sounding Systems
Fire-Fighting Systems
Fire-fighting System
Fire-Fighting Systems

Three groups:
Fire Main
Seawater as fire extinguishing medium
At least two fire pumps and are located in two different
compartments
An international shore connection is provided at port
and starboard for external water supply
System is tested with at least streams of water directed
from one fire pump.
Pressure relief valve is fitted to mains to protect sudden
over-pressure.
Fire-Fighting Systems

Three groups:
Carbon Dioxide system
Dry fire protection
Used in compartments that have potential for fire:
engine room, emergency generator room, paint locker
and galley hood
System is equipped with audio and visual alarm to alert
personnel to evacuate
Prior to CO2 release, ventilation fans and fire damper to
be shut.
Fire-Fighting Systems

Three groups:
Sprinkle system
Wet fire protection mainly for accommodation area
System is filled with fresh water and pressurized by
compressed air
Subsequently, water is supplied from fire main
Sprinkle and fire main systems are separated by an
alarm check valve.
When the pressure in the sprinkle drops below the fire
main fire pressure, the fire main pressure will overcome
the internal pressure of the valve lift and automatically
push open to accommodate the fire main.
Fuel Oil Systems

Main concerns
Fire hazards
Flash point
Insulation
Remote control of fuel oil valves
Stopping of pumps
Collection of drains from leaks
Materials
Fuel oil pipes and their valves and fittings is required to
be of steel or other fire-resistance materials
FO Storage and Transfer

FO Storage and Transfer


FO Storage and Transfer

Important concerns
Overflow pipes
Quick-closing valves
Drain to waste oil tanks (spill trays)
Level gauge with heat-resistant glass for sounding
Remote control of fuel oil valves
Insulation of hot surfaces where fuel oil leaks
(possibly in a spray form) is possible
HFO Settling Tank
HFO Service Tank
Quick-closing Valves
FO Supply to Engine

FO System
FO Supply to Engine

Main components
Storage (bunkers)
Transfer pump
Settling tank
Heater
Purifier
Service tank
Filter
Viscosity controller
Return Tank (10 to 15 minutes engine operation)
HFO Duplex Filter
HFO Transfer Pump
HFO Heater
HFO Separator
HFO Separation System
Diesel Fuel Separation System
Diesel Fuel Separation System
Lubricating Oil Storage and Transfer
Lubricating Oil Storage and Transfer

Main components
Filling from deck to tanks
Main LO storage tank to deliver to ME sump tank
Quick-closing valves operable from outside ER
where valves are below top of tanks (not
applicable for small tanks below 0.5 m3)
Air pipes may terminate inside ER provided their
openings do not constitute a fire hazard
Duplex filters (or self-cleaning) are used without
interrupting operations
Lubricating Oil Circulation System
Lubricating Oil Service Tank
Lubricating Oil Pump
Lubricating Oil Filter Self-cleaning
Lubricating Oil Filter Self-cleaning
Lubricating Oil System - Thermostatic Valve
Shell-and-Tube LO Cooler
Lubricating Oil Purifier
Lubricating Oil Purifier
Seawater Cooling System
Seawater Cooling System

Arrangement
Conventional and Central cooling
High and low sea chests
Suctions are arranged from two sea inlets
preferably on the opposite sides of the ships
Filters can be cleaned without interrupting the
water supply in the system.
Temperature controlled three-way valves to re-
circulate water when the water is cold
Seawater Cooling System
Overboard Discharge
Freshwater Cooling System
Freshwater Cooling System
Freshwater Cooling System

Arrangement
Freshwater from engine is delivered to freshwater
generator (evaporator)
Pressure in the system is regulated by he
expansion tank
Temperature-controlled three-way valves to allow
re-circulation
High-temperature circuit (jacket cooler), low-
temperature circuit (lubricating oil)
Freshwater Generator (Evaporator)
Freshwater Cooler (Plate-type)
Jacket Water Pump
Freshwater Header Tank
Compressed Air System
Compressed Air System

Normally three systems


Starting air
Service air
Control air
Require two main compressors to charge two air
receivers from atmospheric within one hour
Capacity of receivers sufficient to produce:
12 starts for reversible engines
6 starts for non-reversible engines
3 starts for auxiliary engines
Compressed Air System

No connections to other machinery between air


compressors and main air receivers
Emergency air compressor can be diesel driven or
power supplied from emergency generator
Pressure reduction stations and filters are required
to be duplicates
Safety relief valves are fitted at receivers and set at
10% above operating pressure
Compressed air line is classes as Class II due to
high pressure.
Air Compressors
Air Receivers
Auxiliary Air
Receiver
Emergency Air Receiver
Control Air Dryer (Refrigerant-type)
Pressure-reducing Station
Domestic Water System
Domestic
Water
System
Domestic Water System

Freshwater is made by Freshwater generator


(evaporator)
Delivery of water to accommodation from
hydrophore units is by compressed air
Domestic water is sterilized before consumption
Domestic water is heated and then circulated (by
hot-water circulating pumps)
Domestic water is also used by HFO, DO and LO
separators
Hydrophore
unit
Domestic Water Heater
Power Generating System
Generator System
Diesel
Generator
System
Steam System

Steam
System
Steam System

Normally divided into:


Feed water systems
Steam supply
For heating tanks
For heating pipelines
To heat exchangers
Condensate
Heat of exhaust gas is recovered in economizer to
generate steam
Diesel propulsion system is normally fitted with
an auxiliary boiler
Steam System

Steam with pressure above 7 bar or temperature


above 170C are considered Class II piping.
Steam with pressure above 16 bar or temperature
above 300C is of Class I piping.
With respect to materials for valves and fittings in
Class II piping system, grey cast iron may not be
used up to ND 200, pressure up to 13 bar and
temperature up to 250C
Auxiliary Boiler
Cargo Pump Turbine and Condenser