Sei sulla pagina 1di 20

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

FAS MFAS OTUk Overhead

Overhead
OPUk

OPUk
ODUk Overhead Payload

FAS Frame Aligment Signal


MFAS Multi-frame Aligment Signal

Fig. 1 Frame alignment overhead (TT2561EU01TT_0002 Overhead, 5)


1 2 3 4 5 6 7 8

FAS

OA1 OA1 OA1 OA2 OA2 OA2 MFAS

MF
AS 0000 0000
0000 0001

MFAS Sequence
0000 0010
1111 0110 0010 1000
0000 0011

1111 1110
1111 1111
0000 0000
0000 0000

Fig. 2 Frame alignment overhead byte structure (TT2561EU01TT_0002 Overhead, 5)


14 15 16 17 3824

Remaining OPUk Overhead OPUk Payload


overhead 42 bytes 43808 bytes

Fig. 3 OPUk frame location (TT2561EU01TT_0002 Overhead, 7)


14 15 16 17

Remaining
overhead Mapping Specific OPUk Payload

PSI

0 PT
1

RES

PSI - Payload Structure Identifier


255 PT - Payload Type

Fig. 4 OPUk frame structure (TT2561EU01TT_0002 Overhead, 7)


OPUk Overhead

14 15 16 17

RES JC

Remaining RES JC
overhead OPUk Payload
RES JC

PSI NJO PJO

JC - Justification Control
NJO - Negative Justification Opportunity
PJO - Positive Justification Opportunity
PSI - Payload Structure Identifier
RES - Reserved Bytes

Fig. 5 OPUk overhead bytes (TT2561EU01TT_0002 Overhead, 9)


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Frame Alignment Overhead OTUk Overhead

Overhead
RES TCM6 TCM5 TCM4 OPUk

OPUk
ACT FTFL

TCM3 TCM2 TCM1 PM EXP Payload


GCC1 GCC2 APS/PCC RES

RES Reserved
ACT TCM Activation/deactivation Coordination
TCM Tandem Connection Monitoring
FTFL Fault Type and Fault Localization
PM Path Monitoring
EXP Experimental bytes
GCC Generic Communication Channels
APS/PCC Automatic Protection Switching/Protection
Communication Channel
Fig. 6 ODUk overhead (TT2561EU01TT_0002 Overhead, 11)
1 2 3

Multiframe

BDI
TTI BIP-8 BEI STAT
Structure
just for the 1 2 3 4 5 6 7 8
TTI 0
64 frames
SAPI TTI Trail Trace Identifier
15 BIP Bit Interleaved Parity
16
BEI Backward Error Indication
DAPI BDI Backward Defect Indication
31
32 STAT Status
SAPI Source Access Point
Identifier
Operator
DAPI Destination Access Point
Specific Identifier

63

Fig. 7 PM field structure (TT2561EU01TT_0002 Overhead, 11)


1 14 15 3824

Frame
i
OPUk

BIP-8
Frame
OPUk
i+1

Frame
i+2 OPUk
PM

Fig. 8 ODUk BIP-8 insertion (TT2561EU01TT_0002 Overhead, 13)


BDI or BEI

TX RX

Error Error
evaluation evaluation
ERRORS

RX TX

Fig. 9 BDI and BEI insertion (TT2561EU01TT_0002 Overhead, 13)


1 2 3

BDIi
Multiframe TTIi BIP-8i BEIi STATi
Structure
just for the 1 2 3 4 5 6 7 8
TTI 0
64 frames
SAPIi TTI Trail Trace Identifier
15 BIP Bit Interleaved Parity
16
BEI Backward Error Indication
DAPIi BDI Backward Defect Indication
31
32 STAT Status
SAPI Source Access Point
Identifier
Operator
DAPI Destination Access Point
Specific Identifier

63

Fig. 10 TCM field structure (TT2561EU01TT_0002 Overhead, 17)


TCM TCM
insertion extration

Network A Network B

Network C

TCM1 TCM1 TCM1 TCM1 TCM1 TCM1 TCM1


TCM2 TCM2 TCM2 TCM2 TCM2 TCM2 TCM2
TCM3 TCM3 TCM3 TCM3 TCM3 TCM3 TCM3
TCM4 TCM4 TCM4 TCM4 TCM4 TCM4 TCM4
TCM5 TCM5 TCM5 TCM5 TCM5 TCM5 TCM5
TCM6 TCM6 TCM6 TCM6 TCM6 TCM6 TCM6

Fig. 11 TCM monitoring (TT2561EU01TT_0002 Overhead, 17)


SIEMENS
NIXDORF

Generic
Communication
i Channels

Fig. 12 GCC field (TT2561EU01TT_0002 Overhead, 19)


FTFL
Multiframe
Structure
256 0
frames 0 Fault type indication
1
Operator
Forward Identifier
Field 9 Field
10

127
128

Operator
Specific
Backward Field
Field

255 127

Fig. 13 FTFL field (TT2561EU01TT_0002 Overhead, 21)


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Frame Alignment Overhead SM GCC0 RES

Overhead
OPUk

OPUk
Payload
ODUk overhead

RES Reserved
SM Section Monitoring
GCC Generic Communication Channels

Fig. 14 OTUk overhead (TT2561EU01TT_0002 Overhead, 25)


1 2 3

Multiframe

BDI
IAE
TTI BIP-8 BEI RES
Structure
1 2 3 4 5 6 7 8
just for the
TTI 0
TTI Trail Trace Identifier
64 frames SAPI
BIP Bit Interleaved Parity
15
16 BEI Backward Error
DAPI Indication

31 BDI Backward Defect


32 Indication
IAE Incoming Alignment Error
Operator RES Reserved
Specific
SAPI Source Access Point
Identifier
63
DAPI Destination Access
Point Identifier
Fig. 15 OTUk SM field (TT2561EU01TT_0002 Overhead, 25)
1 14 15 3824

Frame i OPUk

BIP-8
Frame i + 1 OPUk

SM
Frame i + 2
OPUk

Fig. 16 OTUk BIP-8 insertion (TT2561EU01TT_0002 Overhead, 27)


OCh
OCh
OCh
OCh
OMS OCh
Overhead
OCh
Overhead
OMS OCh
Overhead
OCh
Overhead
Overhead OCh
Overhead
OCh
Overhead
Overhead Overhead
Overhead
Overhead
Overhead

NO STANDARD
SIGNAL
STRUCTURE
OTS
OTS
Overhead
OOS/OSC
OOS/OSC
Overhead

General
GeneralManagement
ManagementCommunications
Communications

Fig. 17 OSC signal (TT2561EU01TT_0002 Overhead, 31)


OTS TTI
OTS
OTS OTS BDI-P
Overhead
Overhead
OTS BDI-O
OTS PMI

Fig. 18 OTS overhead functionalities (TT2561EU01TT_0002 Overhead, 31)


OMS FDI-P
OMS FDI-O
OMS
OMS
Overhead
Overhead
OMS BDI-P
OMS BDI-O
OMS PMI

Fig. 19 OMS overhead functionalities (TT2561EU01TT_0002 Overhead, 33)


OCh FDI-P
OCh
OCh
Overhead
Overhead
OCh FDI-O
OCh OCI

Fig. 20 OCh overhead functionalities (TT2561EU01TT_0002 Overhead, 35)

Potrebbero piacerti anche