Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Installation
and Configuration
of
Redundant Ring Structures
Rev 1.2/25.11.2004
MICROSENS confidential 1
Industrial Ethernet MICROSEN
S
Preparations
Required Hardware
Standard PC (Management Station) with network access
Required Software
Windows Operating System (Win98, NT, 2000, XP)
MICROSENS Device Manager Software
(Current release: V3.27)
MICROSENS confidential 2
Industrial Ethernet MICROSEN
S
Switch Initialization Buttons
Reset/Init Button
MICROSENS confidential 3
Industrial Ethernet MICROSEN
S
Switch Initialization Options
Reset
Press Reset Button short for restart of switch and management.
Last configuration remains unchanged
Initialization
Press Reset Button for min. 10 seconds (until Link-LEDs turn on
again).
Switch sends request to Device Manager Software for initialization.
Last configuration remains unchanged.
MICROSENS confidential 5
Ring Installation MICROSEN
S
Step 2: Configure IP Address
Start Device Manager Software
Software must be running for initialization
MICROSENS confidential 6
Industrial Ethernet MICROSEN
S
Switch1
Ring Structure 10.1.1.151
Master
Switch5
Switch2 10.1.1.155
10.1.1.152 Slave
Slave Ring #01
Switch3
Switch4
10.1.1.153
10.1.1.154
Slave
Slave
MICROSENS confidential 7
Industrial Ethernet MICROSEN
S
Switch1
Ring Functionality: 10.1.1.151
Normal Operation Master
Switch5
Switch2 10.1.1.155
10.1.1.152 Slave
Slave Ring #01
Switch3
Switch4
10.1.1.153
10.1.1.154
Slave
Slave
MICROSENS confidential 8
Industrial Ethernet MICROSEN
S
Switch1
Ring Functionality: 10.1.1.151
Ring Fault Master
Switch5
Switch2 10.1.1.155
10.1.1.152 Slave
Slave Ring #01
Alarm! Alarm!
Switch3
Switch4
10.1.1.153
10.1.1.154
Slave
Slave
MICROSENS confidential 9
Industrial Ethernet MICROSEN
S
Ring Structure Initialization: Step 1
Install Switches
Do not physically close ring!
Connect Management PC
Switch1
Start Device Manager Software
10.1.1.151
Switch2
Switch5
10.1.1.152
10.1.1.15
5
Device
Manager Switch3 Switch4
10.1.1.153 10.1.1.154
MICROSENS confidential 10
Industrial Ethernet MICROSEN
S
Device Manager: Hardware Settings
Ring Mode Options
Ring Mode
Enable Protected Ring operation
Disable Normal switch operation
Device Type
Ring Master Protection handler, only one Master per ring!
Ring Slave All other devices in ring
Ring Number
Unique number for ring
MICROSENS confidential 11
Industrial Ethernet MICROSEN
S
Ring Structure Initialization: Step 2
Define Standard Settings:
Ring Mode: on
Device type: slave
Ring Number: 1 (or any other) Switch1
Slave
Apply Settings to all Switches
Apply to all Command
Switch5
Switch2
Slave
Slave
Ring
#01
Device
Manager Switch3
Switch4
Slave
Slave
MICROSENS confidential 12
Industrial Ethernet MICROSEN
S
Ring Structure Initialization: Step 3
Define Ring Master
Ring Mode: on
Device type: Master
Ring Number: as defined Switch1
Master
Apply Settings to single Switch
Apply to current Comand
Switch2 Switch5
Slave Slave
Ring
#01
Device
Manager Switch3
Switch4
Slave
Slave
MICROSENS confidential 13
Industrial Ethernet MICROSEN
S
Ring Structure Initialization: Step 4
Close ring structure
Physically close ring
Protection is now working
Switch1
Master
Switch2 Switch5
Slave Slave
Ring
#01
Device
Manager Switch3
Switch4
Slave
Slave
MICROSENS confidential 14
Industrial Ethernet MICROSEN
S
Alarm Notification
SNMP Traps
Alarm notification messages sent to defined Trap receiver when alarm
event occurs. Trap filter for event must be enabled.
Ring Broken Trap
When enabled, a Trap is generated when the link status of a ring port
goes down. This Trap can be used to identify the location of a ring
failure, as it is generated by the stations next to the ring break.
This Trap should be enabled on all devices in the ring.
Ring Alarm Trap
When enabled, a Trap is generated when a switch in the ring reports a
ring failure. This Trap can be used to get a global alarm that the
ring is broken. It should only be enabled on one device (typically
the master) or two devices for redundancy.
MICROSENS confidential 15
Industrial Ethernet MICROSEN
S
Switch1
Alarm Notification: Master
Trap Configuration Trap: Ring Alarm
Ring Broken Switch5
Slave
Trap: Ring Broken
Switch2
Slave
Trap: Ring Broken
Ring #01
Switch3
Slave Switch4
Trap: Ring Broken Slave
Trap: Ring Broken
MICROSENS confidential 16
Industrial Ethernet MICROSEN
S
Switch1
Alarm Notification: Master
Trap: Ring Alarm
Ring Fault Ring Broken Switch5
Slave
Trap: Ring Broken
Switch2
Slave
Trap: Ring Broken
Ring #01
Ring
Broken! Ring
Switch3 Broken!
Slave Switch4
Trap: Ring Broken Slave
Trap: Ring Broken
MICROSENS confidential 17
Industrial Ethernet MICROSEN
S
Alarm Notification:
Trap generation Switch1
Master
Trap: Ring Alarm
Ring Broken
Switch5
Slave
Trap: Ring Broken
Switch2
Slave
Trap: Ring Broken
m
l ar Ring
Trap Receiver A
Switch1: Ring Alarm i ng #01
Switch3: Ring Broken
p :R
Switch4: Ring Broken a
Tr
MICROSENS confidential 18
Industrial Ethernet MICROSEN
S
Thank You!
MICROSENS confidential 19