Sei sulla pagina 1di 12

#GOBEYON

Pa-Pb Power Distribution for 20W, 10 MHz D


CUSTOMER
EXPECTATIO
N
PA
Power utilization rate
-6 -4.77 -3 -1.77 0 1 2 3
0 67% 75% 86% 92% 100% 97% 94% 92%
1 75% 86% 100% 92% 83% 80% 77% 75%
PB
2 86% 100% 83% 75% 67% 63% 61% 58%
3 100% 83% 67% 58% 50% 47% 44% 42%

PA
Max RS power(dBm)
-6 -4.77 -3 -1.77 0 1 2 3
0 19.4 18.8 17.5 16.7 15.2 14.2 13.2 12.2
1 20.0 19.3 18.2 17.0 15.2 14.2 13.2 12.2
PB
2 20.5 20.0 18.2 17.0 15.2 14.2 13.2 12.2
3 21.2 20.0 18.2 17.0 15.2 14.2 13.2 12.2

PA
Total Power of symbol with RS(W)
-6 -4.77 -3 -1.77 0 1 2 3
0 20.0 20.0 20.0 20.0 20.0 19.3 18.8 18.3
1 20.0 20.0 20.0 18.3 16.7 16.0 15.4 15.0
PB
2 20.0 20.0 16.7 15.0 13.3 12.6 12.1 11.7
3 20.0 16.7 13.3 11.7 10.0 9.3 8.8 8.3

PA
Total Power of symbol without RS(W)
-6 -4.77 -3 -1.77 0 1 2 3
0 13.4 15.0 17.2 18.5 20.0 20.0 20.0 20.0
1 15.0 17.1 20.0 20.0 20.0 20.0 20.0 20.0
PB
2 17.2 20.0 20.0 20.0 20.0 20.0 20.0 20.0
3 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0

ETWORK QUALITY MANAGEMENT | 2016


#GOBEYON
Pa-Pb Power Distribution for 30W, 10 MHz D
CUSTOMER
EXPECTATIO
N
PA
Power utilization rate
-6 -4.77 -3 -1.77 0 1 2 3
0 67% 75% 86% 92% 100% 97% 94% 92%
1 75% 86% 100% 92% 83% 80% 77% 75%
PB
2 86% 100% 83% 75% 67% 63% 61% 58%
3 100% 83% 67% 58% 50% 47% 44% 42%

PA
Max RS power(dBm)
-6 -4.77 -3 -1.77 0 1 2 3
0 21.2 20.6 19.3 18.5 17.0 16.0 15.0 14.0
1 21.8 21.1 20.0 18.8 17.0 16.0 15.0 14.0
PB
2 22.3 21.8 20.0 18.8 17.0 16.0 15.0 14.0
3 23.0 21.8 20.0 18.8 17.0 16.0 15.0 14.0

PA
Total Power of symbol with RS(W)
-6 -4.77 -3 -1.77 0 1 2 3
0 30.0 30.0 30.0 30.0 30.0 29.0 28.2 27.5
1 30.0 30.0 30.0 27.5 25.0 24.0 23.2 22.5
PB
2 30.0 30.0 25.0 22.5 20.0 19.0 18.2 17.5
3 30.0 25.0 20.0 17.5 15.0 14.0 13.2 12.5

PA
Total Power of symbol without RS(W)
-6 -4.77 -3 -1.77 0 1 2 3
0 20.0 22.5 25.7 27.7 30.0 30.0 30.0 30.0
1 22.6 25.7 30.0 30.0 30.0 30.0 30.0 30.0
PB
2 25.8 30.0 30.0 30.0 30.0 30.0 30.0 30.0
3 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0
ETWORK QUALITY MANAGEMENT | 2016
#GOBEYON
Pa-Pb Power Distribution for 40W, 10 MHz D
CUSTOMER
EXPECTATIO
N
PA
Power utilization rate
-6 -4.77 -3 -1.77 0 1 2 3
0 67% 75% 86% 92% 100% 97% 94% 92%
1 75% 86% 100% 92% 83% 80% 77% 75%
PB
2 86% 100% 83% 75% 67% 63% 61% 58%
3 100% 83% 67% 58% 50% 47% 44% 42%

PA
Max RS power(dBm)
-6 -4.77 -3 -1.77 0 1 2 3
0 22.4 21.8 20.5 19.7 18.2 17.2 16.2 15.2
1 23.0 22.3 21.2 20.0 18.2 17.2 16.2 15.2
PB
2 23.5 23.0 21.2 20.0 18.2 17.2 16.2 15.2
3 24.2 23.0 21.2 20.0 18.2 17.2 16.2 15.2

PA
Total Power of symbol with RS(W)
-6 -4.77 -3 -1.77 0 1 2 3
0 40.0 40.0 40.0 40.0 40.0 38.6 37.5 36.7
1 40.0 40.0 40.0 36.7 33.3 32.0 30.9 30.0
PB
2 40.0 40.0 33.3 30.0 26.7 25.3 24.2 23.3
3 40.0 33.3 26.6 23.4 20.0 18.6 17.5 16.7

PA
Total Power of symbol without RS(W)
-6 -4.77 -3 -1.77 0 1 2 3
0 26.7 30.0 34.3 36.9 40.0 40.0 40.0 40.0
1 30.1 34.3 40.0 40.0 40.0 40.0 40.0 40.0
PB
2 34.4 40.0 40.0 40.0 40.0 40.0 40.0 40.0
3 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0
ETWORK QUALITY MANAGEMENT | 2016
#GOBEYON
RS Power Setting D
CUSTOMER
EXPECTATIO
N

Rs Power Calculation for Macro Sites with (Pa,Pb) (-3,1) and (0,0 )
Pa=-3 & Pb=1 Pa=0 & Pb=0

2*15W 2*20W 2*15W 2*20W


2*30W 2*40W (RRU3929/RRU (MRFU/MRFU 2*30W 2*40W
(RRU3929/RRU3 (MRFU/MRFU
3939) d/RRU3953)
939) d/RRU3953)
5M [-3.1, 16.9] [-1.8, 18.2] [0, 20.0] [1.2, 21.2]
5M [0, 20.0] [1.2, 21.2] [3.0, 23.0] [4.2, 24.2]
[-3.1, [-1.8,
10M [-3.1, 16.9] [-1.8, 18.2] [0, 20.0] [1.2, 21.2] 10M [-6.1, 13.9] [-4.8, 15.2]
16.9] 18.2]
15M [-4.8, 15.2] [-3.6, 16.4] [-1.8, 18.2] [-0.6, 19.4] [-4.8, [-3.6,
15M [-7.8, 12.2] [-6.6, 13.4]
20M [-6.1, 13.9] [-4.8, 15.2] [-3.1, 16.9] [-1.8, 18.2] 15.2] 16.4]
[-6.1, [-4.8,
20M [-9.1, 10.9] [-7.8, 12.2]
13.9] 15.2]

Rs Power Calculation for Lamp Site with (Pa,Pb) (-3,1) and (0,0)

Pa=-3 & Pb=1 Pa=0 & Pb=0


2*50mW 2*100mW 2*50mW 2*100mW
(pRRU3911) (pRRU3901) (pRRU3911) (pRRU3901)
5M [-14.8, -4.8] [-11.8, -1.8] 5M [-17.8, -7.8] [-14.8, -4.8]
10M [-17.8, -7.8] [-14.8, -4.8] 10M [-20.8, -10.8] [-17.8, -7.8]
15M [-19.6, -9.6] [-16.6, -6.6] 15M [-22.6, -12.6] [-19.6, -9.6]
20M [-20.8, -10.8] [-17.8, -7.8] 20M [-23.8, -13.8] [-20.8, -10.8]

ETWORK QUALITY MANAGEMENT | 2016


#GOBEYON
LTE Power Control Parameter List D
CUSTOMER
EXPECTATIO
N

Parameter related to LTE Power Control for Huawei, Ericssons, Nokia and ZTE is on attached excel
file.

LTE Power
Control Parameter

ETWORK QUALITY MANAGEMENT | 2016


#GOBEYON
Illustration of Power allocation D
CUSTOMER
EXPECTATIO
N

Different PA,PB parameter setting will influence the available Rs power and PDSCH power, which will impact the
network performance

ETWORK QUALITY MANAGEMENT | 2016


#GOBEYON
Impact analysis of different PA,PB setting D
CUSTOMER
EXPECTATIO
N

Illustration of PA,PB=(-3,1) and (0,0) setting in case of 4X10W


PA= -3 PB=1 PA= 0 PB=0

12.2dBm 9.2dBm
9.2dBm 10.17dBm

9.2dBm 9.2dBm
RS is transmitted in all cells , and when the network load is light , the interference of RS received
by PDSCH RBs is lower, while the RS with higher power will interfere data transmission, so
PA,PB=(0,0) setting is better;
When the network load is heavy, then its necessary to ensure RS reliability by boosting RS power
with 3dB, so PA,PB=(-3,1) setting is better in heavy network;
PA,PB=(0,0) setting is better in light network while PA,PB=(-3,1) setting is better
in heavy network
ETWORK QUALITY MANAGEMENT | 2016
#GOBEYON
Pa,Pb Setting and Analysis D
CUSTOMER
EXPECTATIO
N

Neighbor RS channel interference will impact data


quality on serving cell B symbol.

Neighbor data will also be interference to serving


RS. Data demodulation is based on RS channel quality
estimation, so accuracy on RS quality will impact all
data sub channel.
18.2 / -3 / 1 15.2 / 0 / 0
High RS mapping to large
coverage
Better throughput
When network load is medium
Pro experience when low
and above (PRB utilization >
load
30%), high RS will help UE on
access and mobility
When network load is low (PRB RSRP will be 3dB lower
utilization < 30%), data
channel interference is major SINR reduce by ~2dB
Con
from neighbor cell RS channel. (PDSCH data channel
High RS will impact overall DT SINR remain)
throughput.

For normal scenario, Pa & Pb = (-3, 1);


for
ETWORK lowMANAGEMENT
QUALITY PRB utilization
| 2016 scenario and throughput benchmark test scenario, Pa and Pb = (0, 0);
#GOBEYON
Cell Specific RS Power Setting D
CUSTOMER
EXPECTATIO

(Cont.)
N

3/4 1 1

P Power of type B symbol / Power of
B

3/4 1 1 type A Symbol



1 ANT port 2 or 4 ANT ports
1 1
X X
compensat 0 1 5/4
3/4 1 1
e
1 4/5 1
3/4 1 1
2 3/5 3/4

1 1 3 2/5 1/2
R R

3/4 1 1

compensat Bandwidt PB PRS ( dBm)
3/4 1 1
e h

1 1
X

X 10M 1 18.2
P3/4
B =21 , 12 Antennas
15M 1 16.4

3/4 1 1
20M 1 15.2
2 antennas, 20w per antenna
1 1
R R

RS Power Total power per channel(dBm) 10lg(total
subcarrier)+10lg(PB + 1)

ETWORK QUALITY MANAGEMENT | 2016 Page9


#GOBEYON
Cell Specific RS Power Setting D
CUSTOMER
EXPECTATIO
N

Type A Symbol: without RS REs Type B Symbol: RS REs

EPRE: Energy Per Resource Element


The power setting is based on EPRE
EA (EPRE Type A) = Energy Per RE that doesnt have Rs Power
in the symbol
EB (EPRE Type B) = Energy Per RE that have Rs Power in the
symbol
ER = Energy per Reference Signal Power RE
ETWORK QUALITY MANAGEMENT | 2016 Page10
#GOBEYON
RRU Power
Summary Case Example D
CUSTOMER
EXPECTATIO
N

Frequency allocation for 1 MHz = 5 Resource Block (RB) * every RB contain


12 Resource Element (RE)

For 10 MHz, Power 20 W EPRE Type A= 20000mW/
(10MHz*5*12)=33.33mW=10log(33.33)=15.22dBm
Formula
For 10 MHz, Power 40 W EPRE Jika
TypePa,Pb di set (-3,1)
A= 40000mW/ Jika Pa,Pb di set (0,0):
(10MHz*5*12)=66.66mW=10log(66.66)=18.23dBm
Pa=Ea/Er Pa=Ea/Er
-3dB=Ea/Er 0dB=Ea/Er
-3dB=10log(Ea/Er) 0dB=10log(Ea/Er)
=Ea/Er 1=Ea/Er
Er=2Ea Er=Ea

Jika Ea=15.22dBm, Jika Ea=15.22dBm,


Er= 2Ea=3dB+15.22dBm= 18.22dBm Er=15.22dBm
Jika Ea=18.23dBm, Jika Ea=18.23dBm,
Er= 2Ea=3dB+15.23dBm= 21.23dBm Er=18.23dBm

(5-Pb)/4=Eb/Ea (5-Pb)/4=Eb/Ea
(5-1)/4=Eb/Ea (5-0)/4=Eb/Ea
Eb=Ea Eb=1.25Ea

Jika Ea=15.22dBm, Jika Ea=15.22dBm,


Eb=15.22dBm Eb=1.25(15.22dBm)=1.25(33.33mW)
Jika Ea=18.23 dBm, =41.63mW=16.19dBm
Eb=18.23dBm Jika Ea=18.23dBm,
Eb=1.25(18.23dBm)=1.25(66.66mW)
=83.32mW=19.2dBm
ETWORK QUALITY MANAGEMENT | 2016
#GOBEYON
RRU Power
Summary Case Example D
CUSTOMER
EXPECTATIO
N

Every symbol need to have the same total energy


accumulation, in one symbol there are 2 RB
configuration possibilities:
Type A Symbol -> 12 EA
Type B Symbol -> 8EB + 2ER
So Pa, Pb settings have to follow ->
8EB+2Er=12 EA

Pa,Pb (-3,1) -> Er=2Ea, Eb=Ea
8Eb+2Er=12Ea
8Ea+2(2Ea)=12Ea
12Ea=12Ea

Pa,Pb) (0,0) -> Er= Ea, Eb=1.25Ea
8Eb+2Er=12Ea
10Ea+2(Ea)=12Ea
12Ea=12Ea

ETWORK QUALITY MANAGEMENT | 2016