Sei sulla pagina 1di 14

.

prepared by: Dr.Ahmed Baaleh

?What is the meaning

TXP is renamed to SPPA-T2000


(Siemens Power Plant Automation)
2

prepared by: Dr.Ahmed Baaleh

The highlights of TelepermXP


Application from small to large plants
through

Powerful subsystems

high degree of modularity


step by step performance

Step by step automation up to the One Man


Control Room

Open communications

Decentralized processing

Interface to systems of other suppliers

Uniform
MMI
for
Process
-information and management

Standards

High processing density

Relation Database with SQL

Integrated
automation
programs

ISO/OSI communication

Integrated diagnostic system

Integrated Plannable redundancy

Integrated commissioning tool

Unix, X-Windows

control,

forward documentation and


code generation of user

prepared by: Dr.Ahmed Baaleh

Modularity

The OM650 process control and information functions have been


subdivided into packages, which - with respect to the software involved - are further
subdivided into function blocks.
This modular design not only increases the option variations of the
system but also improves the possibilities of optimally matching the
system to the various requirements made by plants of different sizes and
tasks. However, all tasks are processed under a common organization
structure so that a uniform user interface can be used. This common
organization provides common data management and the possibility of
common evaluation covering the entire plant without the modular design of
the functions being apparent to the user. Distributed data management
allows almost unlimited system extension without limiting the
performance of each individual component.

prepared by: Dr.Ahmed Baaleh

TELEPERM XP Components

prepared by: Dr.Ahmed Baaleh

TELEPERM XP Components
The TELEPERM XP (TXP) process control system provides all I&C facilities that
are necessary for automating,handling, monitoring, and archiving processes
(such as the operational instrumentation and control systems of power
plants).
The tasks of a process control system are distributed to different subsystems:
- OM 650: Operating and Monitoring system. This is the process control and
information system for operator--process communication and visualization.
- ES 680: Engineering System. This system is employed for configuration and
commissioning.
- DS 670: Diagnostic System.
- SINEC H1: SIEMENS Network Communication. Communication system.
- AS 620: Automation System. This is the system used for process automation.

prepared by: Dr.Ahmed Baaleh

TXP sub systems

prepared by: Dr.Ahmed Baaleh

Homogeneous Structure from field to plant Management


The communication between OM
and AS is done via Plant bus
The internal communication within
OM is done via Terminal bus
The ES is used for configuring both
systems: OM and AS. For this
reason it is connected with both
Plant and Terminal buses
All this communication paths are
part of LAN (Local Area
Network)
Communications to external WAN
(wide Area Network) is possible
via gateways

prepared by: Dr.Ahmed Baaleh

The SINEC H1 Bus System

The SINEC H1 bus system network allows intercommunication between the distributed
autonomous components of the process control system. The bus system complies with
international standards hence providing functions required for open communication.
This means that not only system components but also equipment from other product
lines or from other vendors can be connected.

The SINEC H1 is based on the standardized access procedure CSMA/CD featuring the
very high baud rate of 10 MBits/s. The bus system is available either with triaxial cable
or with fiber optic cable SINEC H1FO (Fiber Optic). The major advantage of the version
using fiber optics is that it guarantees electrical isolation between the partners to the
communication and reliable protection against electromagnetic interference.

prepared by: Dr.Ahmed Baaleh

The World of TXP I&C Architecture


Operation &
Monitoring level

Processing level

Group control
level

Individual control
level

Filed level

10

prepared by: Dr.Ahmed Baaleh

The AS 620 Automation System

The AS 620 system executes the tasks of the group and individual control levels. It acquires
measured values and statuses from the process, carries out open-- and closed--loop control
functions and issues the resulting commands on to the process.
At the same time, the AS 620 represents the interface to the process for the other
TELEPERM XP systems. It transfers commands from the OM 650 operation and monitoring
system to the process, and reads in information required by the OM 650 from the process
and passes it on to the operation and monitoring level.
Corresponding to the various requirements which have to be met by measurement, open
and closed--loop control during normal operation as well as those requirements to be met by
the safety--related tasks of the boiler and the fast changes in the turbine,
three AS 620automation system versions are available:
- The AS 620 B (Basis) for general automation tasks ranging from the protection of an
auxiliary device up to the unit co--ordination controller.
- The AS 620 F (Fail--Safe) for safety--related protection tasks (of the boiler, for
example) and controls subject to approval (such as burner controls).
- The AS 620 T (Turbine) for the fast closed--loop control of the turbine.
For I&C system tasks in ancillary plants, automation devices from the SIMATIC S5 (S5--AG)
system range can be used with the corresponding standard peripheral equipment (SIM S5).
As these devices are connected to the AP automation processor, they are also integrated
into the communication system.

11

prepared by: Dr.Ahmed Baaleh

:Important features of the OM 650 system

12

Pixel-graphics desktop (HMI)


Uniform HMI for process control, information and management
Operator-optimized operation philosophy
Display of information based on plant, process and I&C aspects
Decoupling of processing units and operating terminals
Central configuring using the ES 680 Engineering System
Scalable hardware and software concept
Distribution of data and functions
Function packages for process control, information and
management
Configurable redundancy for all components
Incorporation of international standards (UNIX, relational database
system with SQL interrogation language).

prepared by: Dr.Ahmed Baaleh

:Important features of the ES 680 system

The ES 680 engineering system supports the engineering steps


system-wide. A typical engineering procedure is as follows:

Entry of project data (e.g. plant name, functional complexes, person


responsible, etc.)

Equipment structure (topology, cabinet layout, module structure)

Creation of area and overview diagrams (optional)

Planning the function diagrams of the single-loop level


(automation/log functions).

13

prepared by: Dr.Ahmed Baaleh

:Important features of the DS 670 system

14

Automatic detection and acquisition of I&C faults


Conditioning of the detected faults and compressed presentation
(alarm compression) in graphical form within an I&C equipment
structure display
Interactive user guidance to the fault (localization) through the
equipment structure
Presentation of the fault in graphics and text with detailed
information and, if possible, with suggestions for repairs
Log, statistical and evaluation functions
Provision of I&C-related information, such as
- I&C equipment structure
- Automation system and cabinet configuration
- Versions for hardware and software.

prepared by: Dr.Ahmed Baaleh