Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Introduction
The BTS commissioning & SW files are stored on the station unit module
(SUMA)
The Station unit module is the core of the BTS ,it is responsible for
The O&M Functions such as Alarms reporting ,BTS Configuration,
internal Power Supply control & clock generation and distribution
Transmission functions by connecting the BTS to the BSC through the
ABIS cable.
The ABIS can carry up to 32 time slots
0 to 30 are assigned to the TRES for normal traffic(voice and Data
services)
31 : is assigned to the OMU in the SUMA card for signaling (Control
information) between BSC & BTS such as Alarm reporting ,BTS
Master file Download, configuration files etc..
ABIS
O&M
FAUL
T
Color
Status Description
Yellow
On
Blinking
Off
Link disconnected.
On
Blinking
Off
On
Blinking
Off
On
Blinking
Off
No alarm.
Yellow
Yellow
RED
Offline
Wait for the BTS to download all the files ,During the SW
Download the Suma LED Status will be :
OML ,ABIS & O&M Flashing
last file to be downloaded is the OCPF 002 file after that the
O&M will be solid
Commissioning
The BTS Terminal program will start to load the BTS Data
Take snapshots and check with OMC
Thank You