MULTITESTER
ANALOG MULTITESTER
DIGITAL MULTITESTER
Zero corrector:
Use to set the meter pointer to
Zero position at the left side of
The meter panel
Range selector:
It is used to adjust the proper
Function range for specific
measurement
Dial pointer
Dial scale:
DC voltage
range
AC voltage range
Ohmmeter : is an instrument
Used for measuring resistance.
Resistance
Test probe
+&SYSTEMS PLUS COMPUTER COLLEGE
PARTS OF MULTITESTER
Front panel
Dial scale
Dial pointer
Zero corrector
Zero ohms
adjustment
DC voltage
Test prove/
socket
AC voltage range
Dial selector
resistance
DC VOLTMETER:
1. When operating on .1 volt range, we utilize the 10 volts scale and
Shift the decimal two places to the left. (.01 as multiplier )
Range used
DCV/0.1
Scale used
0-10
Scale reading
4.4
multiplier
.01
Actual reading
0.44
DC VOLTMETER:
2. If the instrument is
operated on 0.5 v range,
we utilize the 50 v
scale and move the
decimal point two places
to the left.
(.01 as multiplier )
Range used
Scale used
Scale reading
multiplier
Actual reading
DCV/0.1
0-10
4.4
.01
0.44
DCV/.5
0-50
22
.01
0.22
DC VOLTMETER:
3. When VOM is set to 2.5 v
range, we use the 250 v
scale and shift
the decimal point two
laces to d left ( .01 as
multiplier )
Range used
Scale used
Scale reading
multiplier
Actual reading
DCV/0.1
0-10
4.4
.01
0.44
DCV/.5
0-50
22
.01
0.22
DCV/2.5
0-250
110
.01
1.10
DC VOLTMETER:
4. VOM is operated on 10 v
range,
we utilize the 10 v scale and
read directly or set 1 as
multiplier
Range used
Scale used
Scale reading
multiplier
Actual reading
DCV/0.1
DCV/.5
0-10
0-50
4.4
22
.01
.01
0.44
0.22
DCV/2.5
0-250
110
.01
1.10
DCV/10
0-10
4.4
4.4
DC VOLTMETER:
5. VOM is operated on 50 v
range, we utilize the 50 v
scale and read
directly or set 1 as
multiplier
Range used
Scale used
Scale reading
multiplier
Actual reading
DCV/0.1
DCV/.5
0-10
0-50
4.4
22
.01
.01
0.44
0.22
DCV/2.5
0-250
110
.01
1.10
DCV/10
0-10
4.4
4.4
DCV/50
0-50
22
22
DC VOLTMETER:
6. VOM is operated on 250 v
range, we utilize the 250 v
scale and read
directly or set 1 as
multiplier
Range used
Scale used
Scale reading
multiplier
Actual reading
DCV/0.1
DCV/.5
0-10
0-50
4.4
22
.01
.01
0.44
0.22
DCV/2.5
0-250
110
.01
1.10
DCV/10
0-10
4.4
4.4
DCV/50
0-50
22
22
DCV/250
0-250
110
110
DC VOLTMETER:
Scale used
DCV/0.1
DCV/.5
DCV/2.5
DCV/10
DCV/50
0-10
0-50
0-250
0-10
0-50
0-250
0-10
DCV/250
DCV/1000
Scale reading
4.4
22
110
4.4
22
110
4.4
multiplier
.01
.01
.01
1
1
1
100
Actual reading
0.44
0.22
1.10
4.4
22
110
440
DC VOLTMETER
Range used
Scale used
Scale reading
multiplier
Actual reading
DCV/0.1
DCV/.5
0-10
0-50
4.4
22
.01
.01
0.44
0.22
DCV/2.5
0-250
110
.01
1.10
DCV/10
DCV/50
0-10
0-50
4.4
22
1
1
4.4
22
DCV/250
0-250
110
110
DCV/1000
0-10
4.4
100
440
AC VOLTMETER READING
Scale
used
Scale
reading
multiplier
Actual
reading
ACV/10
0-10
2.4
2.4
ACV/50
0-50
12
12
ACV/250
0-250
60
60
ACV/1000
0-10
2.4
100
240
DC CURRENT METER
RANGE
USED
SCALE
USED
SCALE
READING
MULTIPLIER
ACTUAL
READING
DCA/50 UA
0-50
32
32UA
DCA/2.5MA
0-250
160
.01
1.6MA
DCA/25 MA
0-250
160
.01
1.6MA
DCA/.25A
0-250
160
.001
.16A
RANGE
USED
SCALE
USED
SCALE
READING
MULTIPLIER
ACTUAL
READING
DCA/50 UA
0-50
32
32UA
DCA/2.5MA
0-250
160
.01
1.6MA
DCA/25 MA
0-250
160
.01
1.6MA
DCA/.25A
0-250
160
.001
.16A
SCALE
USED
SCALE
READING
MULTIPLIER
ACTUAL
READING
DCA/50 UA
0-50
32
32UA
DCA/2.5MA
0-250
160
.01
1.6MA
DCA/25 MA
0-250
160
.01
1.6MA
DCA/.25A
0-250
160
.001
.16A
SCALE
USED
SCALE
READING
MULTIPLIER
ACTUAL
READING
DCA/50 UA
0-50
32
32UA
DCA/2.5MA
0-250
160
.01
1.6MA
DCA/25 MA
0-250
160
.01
1.6MA
DCA/.25A
0-250
160
.001
.16A
Testing voltage:
From battery which
Is a DC voltage
PARTS OF MULTITESTER
1
5
8
6
3
10
4
9