MULTITESTER

SYSTEMS PLUS COMPUTER COLLEGE


Commitment to Excellence
2 KINDS OF MULTITESTER

ANALOG MULTITESTER

SYSTEMS PLUS COMPUTER COLLEGE


Commitment to Excellence
2 KINDS OF MULTIESTER

DIGITAL MULTITESTER

SYSTEMS PLUS COMPUTER COLLEGE


Commitment to Excellence
MULTIMETER
Is an indispensable for a technician as firearms for a
Soldier. The interpretation of readings gives technician
Clues to trouble-shooting.

Zero ohms adjustments:


Use to set the pointer exactly
On zero position at the right
side of meter panel

Zero corrector:
Use to set the meter pointer to
Zero position at the left side of
The meter panel

Range selector:
It is used to adjust the proper
Function range for specific
measurement

Dial pointer

Dial scale:

Voltmeter: is an instrument is used


Measuring voltage or potential
difference

Observed polarity in measuring


DC voltage and current.

Always set at higher range of meter

DC voltage
range

SYSTEMS PLUS COMPUTER COLLEGE

1. Before taking a measurement,


the pointer position should be
confirmed to zero on the top
ohm scale.
2. With the + and COM terminals
shorted together, the meter is
adjusted by turning the zero
ohm adj. to the right or left in
order to place on zero at right.
3. Always set the meter pointer on
the highest range of there
function, if measuring an unknown
voltage or current.

AC voltage range

SYSTEMS PLUS COMPUTER COLLEGE

Ohmmeter : is an instrument
Used for measuring resistance.

Always remember the:


1. Zero ohms adjustment
2. Zero corrector

Resistance

Test probe
+&SYSTEMS PLUS COMPUTER COLLEGE

PARTS OF MULTITESTER
Front panel

Dial scale

Dial pointer

Zero corrector
Zero ohms
adjustment
DC voltage
Test prove/
socket

AC voltage range
Dial selector
resistance

SYSTEMS PLUS COMPUTER COLLEGE


Commitment to Excellence
Voltmeter:
Is used when it is
necessary to
determine the
presence or absence
of an electrical
pressure or voltage on
a unit under test.
Tester has two voltmeter
functions:
1. AC or alternating
current
2. DC or Direct current

DC VOLTMETER:
1. When operating on .1 volt range, we utilize the 10 volts scale and
Shift the decimal two places to the left. (.01 as multiplier )
Range used

DCV/0.1

Scale used

0-10

Scale reading

4.4

multiplier

.01

Actual reading

0.44

DC VOLTMETER:
2. If the instrument is
operated on 0.5 v range,
we utilize the 50 v
scale and move the
decimal point two places
to the left.
(.01 as multiplier )

Range used

Scale used

Scale reading

multiplier

Actual reading

DCV/0.1

0-10

4.4

.01

0.44

DCV/.5

0-50

22

.01

0.22

DC VOLTMETER:
3. When VOM is set to 2.5 v
range, we use the 250 v
scale and shift
the decimal point two
laces to d left ( .01 as
multiplier )

Range used

Scale used

Scale reading

multiplier

Actual reading

DCV/0.1

0-10

4.4

.01

0.44

DCV/.5

0-50

22

.01

0.22

DCV/2.5

0-250

110

.01

1.10

DC VOLTMETER:
4. VOM is operated on 10 v
range,
we utilize the 10 v scale and
read directly or set 1 as

multiplier

Range used

Scale used

Scale reading

multiplier

Actual reading

DCV/0.1
DCV/.5

0-10
0-50

4.4
22

.01
.01

0.44
0.22

DCV/2.5

0-250

110

.01

1.10

DCV/10

0-10

4.4

4.4

DC VOLTMETER:
5. VOM is operated on 50 v
range, we utilize the 50 v
scale and read
directly or set 1 as
multiplier

Range used

Scale used

Scale reading

multiplier

Actual reading

DCV/0.1
DCV/.5

0-10
0-50

4.4
22

.01
.01

0.44
0.22

DCV/2.5

0-250

110

.01

1.10

DCV/10

0-10

4.4

4.4

DCV/50

0-50

22

22

DC VOLTMETER:
6. VOM is operated on 250 v
range, we utilize the 250 v
scale and read
directly or set 1 as
multiplier
Range used

Scale used

Scale reading

multiplier

Actual reading

DCV/0.1
DCV/.5

0-10
0-50

4.4
22

.01
.01

0.44
0.22

DCV/2.5

0-250

110

.01

1.10

DCV/10

0-10

4.4

4.4

DCV/50

0-50

22

22

DCV/250

0-250

110

110

DC VOLTMETER:

7. VOM is operated on 1000 v


range, we utilize the 25 v
scale and
shift decimal point two
places to d right ( 100 as
multiplier )
Range used

Scale used

DCV/0.1
DCV/.5
DCV/2.5
DCV/10
DCV/50

0-10
0-50
0-250
0-10
0-50
0-250
0-10

DCV/250
DCV/1000

Scale reading

4.4
22
110
4.4
22
110
4.4

multiplier

.01
.01
.01
1
1
1
100

Actual reading

0.44
0.22
1.10
4.4
22
110
440

DC VOLTMETER

Range used

Scale used

Scale reading

multiplier

Actual reading

DCV/0.1
DCV/.5

0-10
0-50

4.4
22

.01
.01

0.44
0.22

DCV/2.5

0-250

110

.01

1.10

DCV/10
DCV/50

0-10
0-50

4.4
22

1
1

4.4
22

DCV/250

0-250

110

110

DCV/1000

0-10

4.4

100

440

AC VOLTMETER READING

AC VOLTMETER READING CHART


Range
used

Scale
used

Scale
reading

multiplier

Actual
reading

ACV/10

0-10

2.4

2.4

ACV/50

0-50

12

12

ACV/250

0-250

60

60

ACV/1000

0-10

2.4

100

240

DC CURRENT METER

1. 50 Micro ampere range,


we utilize the 50 v
scale and
read directly

RANGE
USED

SCALE
USED

SCALE
READING

MULTIPLIER

ACTUAL
READING

DCA/50 UA

0-50

32

32UA

DCA/2.5MA

0-250

160

.01

1.6MA

DCA/25 MA

0-250

160

.01

1.6MA

DCA/.25A

0-250

160

.001

.16A

2. To read current in the 2.5ma range, read the 0-250


and move decimal point to places to d left

RANGE
USED

SCALE
USED

SCALE
READING

MULTIPLIER

ACTUAL
READING

DCA/50 UA

0-50

32

32UA

DCA/2.5MA

0-250

160

.01

1.6MA

DCA/25 MA

0-250

160

.01

1.6MA

DCA/.25A

0-250

160

.001

.16A

3. Move decimal point just once to the left


RANGE
USED

SCALE
USED

SCALE
READING

MULTIPLIER

ACTUAL
READING

DCA/50 UA

0-50

32

32UA

DCA/2.5MA

0-250

160

.01

1.6MA

DCA/25 MA

0-250

160

.01

1.6MA

DCA/.25A

0-250

160

.001

.16A

4. Move decimal point 3 places to d left


RANGE
USED

SCALE
USED

SCALE
READING

MULTIPLIER

ACTUAL
READING

DCA/50 UA

0-50

32

32UA

DCA/2.5MA

0-250

160

.01

1.6MA

DCA/25 MA

0-250

160

.01

1.6MA

DCA/.25A

0-250

160

.001

.16A

SYSTEMS PLUS COMPUTER COLLEGE


Commitment to Excellence

Testing voltage:
From battery which
Is a DC voltage

PARTS OF MULTITESTER