Sei sulla pagina 1di 60

SM6

Range presentation
Protection
des transfos MT BT

Contents

I.

SM6 Market place

II.

Experience of a world leader

III.

Range presentation

IV.

Technological advantages

V.
VI.

Competition
Annex

02-2005

2
2

Contents

I.

SM6 Market place

II.

Experience of a world leader

III.

Range presentation

IV.

Technological advantages

V.

Competition

VI.

Annex

02-2005

3
3

SM6 Market place


MV/LV transformer substations

Sommaire

02-2005

4
4

SM6 Market place


Segmentation
Energy

Building

HV/MV
subtransmission

MV/MV
subtransmission

MV/LV
distribution

Fluair/MCset

SM61250A
SM6 1250A

SM6 630A

RM6

02-2005

Industry

SM6 1250A

SM6 630A

SM6 630A

RM6

5
5

SM6 Market place


Industrial distribution substations : applications

02-2005

6
6

Contents

I.

SM6 Market place

II.

Experience of a world leader

III.

Range presentation

IV.

Technological advantages

V.

Competition

VI.

Annex

02-2005

7
7

The experience of a world leader

To ensure unsurpassed know-how


30 years of SF6 use
45 years of expertise in factory-built cubicles
700 000 SM6 units in operation
More than 1 200 000 SF6 switch units sold
Quality service
Widespread sales network

SM6 24

02-2005

SM6 36

8
8

Worldwide plants organized to supply at a


very short delivery time
Schneider licencies

Schneider industrial plants:


China
Spain
Italy
Belgium
Russia
Vietnam
Etc

USA

02-2005

9
9

Overall quality

EDF/SEPIA
quality audit
Annual production
line sampling
Production sites
with ISO 9002
certification by AFAQ
ISO 14001 to meet
environmental rules

02-2005

10
10

Contents

I.

SM6 Market place

II.

Experience of a world leader

III.

Range presentation

IV.

Technological advantages

V.

Competition

VI.

Annex

02-2005

11
11

An adapted range for all your requirements

Extension possibilities
Easy installation
Operating safe and easy
Compact design to save
space
Soft maintenance
Factory built assemblies
Protection and control
monitoring functions

02-2005

12
12

Compartmented factory built cubicles

Switch cubicles

4
3

1. Switch
2. Busbars
3. Operating mechanism
4. Low voltage
5. Connection

5
02-2005

13
13

Compartmented factory built cubicles

Switch fuse cubicles

4
3

1. Busbars
2. Switch
3. Operating mechanism
4. Low voltage
5. Connection
6. Fuse

6
5
02-2005

14
14

Compartmented factory built cubicles

SF6 circuit breaker cubicles

2
3

1. Switch
2. Busbars
3. Operating mechanism
4. Low voltage
5. Connection and switchgear

3
02-2005

15
15

Compartmented factory built cubicles

Vacuum circuit breaker cubicles

2
1

3
5

1. Switch
2. Busbars
3. Operating mechanism
4. Low voltage
5. Connection and switchgear

3
02-2005

16
16

Compartmented factory built cubicles

Contactor cubicles

2
4
1

1. Switch and contactor


2. Busbars
3. Operating mechanism
4. Low voltage
5. Connection and switchgear

5
02-2005

17
17

SM6 Product view

Safe and easy operation: total confidence

02-2005

3 positions switch and natural interlock


Clear symbols and animated mimic panel
Anti - reflex lever
Earthing switch with making capacity
Compartmented cubicle
Internal arc withstand (Safety membrane on the core )

18
18

1250 A range ...

To be present on MV / MV subtransmission market in the countries


where the metalclad concept is not really specify in primary activity
Same size as 630 A cubicle
Developing the same functions with fix and withdrawable offers
Range is limited to a disconnector and circuit breaker cubicle

02-2005

19
19

36 kV range ...

To break into the Turkish market and to satisfy other countries


through France
Same function as 24 kV range limited at CB fixed
To move from traditional solution in the air to a prefabricated Offer
Homogeneous range with 24 kV SM6 range

02-2005

20
20

Integrated protection chain

DM1-S : SF1 circuit breaker


DMV-S : Evolis circuit breaker
DM1-A : SFset circuit breaker
Reliable protection chain
Without low voltage supply

02-2005

21
21

Internal Arc withstand

2 performances:
Regular 12,5kA.0,7s
Range 16kA.1s

Range 16 kA.1s Bottom gas release

02-2005

Range 16 kA.1s Roof gas release

22
22

DMV A, D & S: vacuum CB cubicle ...

SM6 with CB vacuum


an optimised Offer
Strong points
Pre-engineered Offer
including LV
Reduced size
Earthing switch with full
making capacity & load
break switch
Increase in endurance
performance

02-2005

Width 625 mm
instead of
750 mm

Fixed circuit
breaker
Access to
cables
compartment

23
23

Contents

I.

SM6 Market place

II.

Experience of a world leader

III.

Range presentation

IV.

Technological advantages

V.

Competition

VI.

Annex

02-2005

24
24

Technological advantages:
Load break switch

Switchgear (switch and


disconnector) compartment

02-2005

Very low pressure (0,4 bar relative)


Sealed pressure system
safety membrane
Switch - disconnector
Earthing switch

25
25

Technological advantages:
Load break switch

3 positions switch
Making capacity of earthing switch
Optimised breaking technology

Closed

02-2005

Open

Earthed

26
26

Technological advantages:
Positive break

Position indicator on operating shaft


Direct and reliable transmission mechanism
Natural interlocking

Closed

02-2005

Open

Earthed

27
27

Technological advantages:
Busbar compartment

Connection

in horizontal plane
Field distributors
Insulated busbars
No risk of error

02-2005

28
28

Technological advantages:
Connection and switchgear compartment

02-2005

All types of cables


up to 240 mm - 630 A
up to 630 mm - 1250
Single - handed connection
Field distributors
Fluarc SF1, Sfset, Evolis circuit
breakers

29
29

Technological advantages:
wide CB range
SF1 circuit breaker : 630 or 1250 A
Combined with an electronic relay and standard sensors
Auxiliary power supply

02-2005

30
30

Technological advantages:
wide CB range
SFset enhanced circuit breaker - 630 A
Special sensors
Dedicated electronic relays
No auxiliary power supply

02-2005

31
31

Technological advantages:
wide CB range
Vaccum type circuit breaker : Evolis switchgear
Combined with an electronic relay and standard sensors
Auxiliary power supply

02-2005

32
32

Technological advantages
Low voltage : 3 offers

Cover
H = 1m60

02-2005

Cabinet H = 2m05

Compartment H = 1m69

33
33

Technological advantages
VIP relay
Used without auxiliary
supply
Transformer protection :
VIP 35 : overcurrent
protections and earth fault
100

Network protection :
VIP 300 : overcurrent
protections and earth
fault
VIP 200 and 201 : used
with SFset circuit breaker

10

t>

t>

t >>

t >>

0.1

0.01

I/Is
01.2

10

15

20

25

30

02-2005

Is 1.2 Is

10 Is

I >>

Is 1.2 Is 10 Is

I >>

34
34

Sepam range : protection , control and


monitoring

Sepam range : protection , control &


monitoring

Sepam 20 serie :
For common
applications

Sepam 80 serie :
For complete
applications
Sepam 40 serie :
For demanding
applications

02-2005

Sepam 2000 serie:


For advanced
applications

35
35

Sepam range performances

Effective protection
To meet your exact requirements( common up to
advanced applications )
Accurate measurements detailed diagnosis
Measuring all necessary network monitoring
Network , machine and apparatus diagnosis
Integral equipment control
Pre-defined control functions , suited to all types of
switcher
Remote operation
Open and Modbus protocoi
Comprehensive operator data: measurements,
events logging, etc...

02-2005

36
36

Technological advantages
Factory built cubicles
For protection and control / monitoring systems
Accessible with cables and busbars energised

02-2005

37
37

Contents

I.

SM6 Market place

II.

Experience of a world leader

III.

Range presentation

IV.

Technological advantages

V.

Competition

VI.

Annex

02-2005

38
38

Competition
Design cubicle
2 modular families
Totally

insulated--> RM6
Air Insulated System (AIS)-->SM6

2 earthing switch families


In

the SF6--> SM6 & RM6


In the air

2 CB families
With

SF6--> RM6 & SM6


With vacuum -->SM6

02-2005

39
39

Competition
Mains advantages

3 positions switch in front of conventional family


Withdrawable CBs cubicle
SF6 or Vacuum CBs unit
Easy to manufacture for Panel Builders
Features
24 kV - 20 kA - 630 A and 12 kV - 25 kA - 630 A
24 kV - 20 kA - 1250 A and 12 kV - 25 kA - 1250 A
Comprehensive range with easy adaptation
Local adaptation
Commercial agencies

02-2005

40
40

Contents

I.

SM6 Market place

II.

Experience of a world leader

III.

Range presentation

IV.

Technological advantages

V.

Competition

V.

Annex

02-2005

41
41

Annex
Connection to networks
Incoming or outgoing unit

IM

02-2005

IMC

Outgoing unit, right or


left with or whithout
earthing switch

IMB

42
42

Annex
Protection by fuse - switch combination
Fuses - switch unit

PM

02-2005

Fuses - switch
combination unit

QM

43
43

Annex
Protection by fuse - switch combination
Fuses - switch combination unit

QMC

02-2005

Fuses - switch combination


unit, right or left outgoing
line

QMB

44
44

Annex
Fuses selection

02-2005

45
45

Annex
Protection by contactor
Contactor unit

CRM

02-2005

Fused - contactor unit

CRM

46
46

Annex
Protection by circuit breaker
Single - isolation circuit
breaker unit

DM1-A or DMV-A

02-2005

Single - isolation circuit


breaker unit right or left
outgoing line

DM1-D or DMV-D
(right only)

47
47

Annex
Protection by circuit breaker
Single-isolation circuit breaker
unit with autonomous protection

DM1-S or DMV-S

02-2005

Single - isolation circuit


breaker unit right or left
outgoing line

DM2

48
48

Annex
Protection by circuit breaker
Withdrawable single isolation circuit breaker
unit cable outgoing

DM1 - W

02-2005

Withdrawable single isolation circuit breaker unit


right or left outgoing line

DM1 - Z

49
49

Annex
Protection MV metering
Voltage transformers for
mains with earthed neutral
system

CM (375 mm)

02-2005

Voltage transformers for


mains with insulated neutral
system

CM2 (500 mm)

50
50

Annex
Protection MV metering
Current and / or voltage
measurement unit, right or
left outgoing line

GBC - A

02-2005

Current and / or voltage


measurement unit

GBC - B

51
51

Annex
Functions required by private networks
Intermediate bus
unit

GIM

02-2005

Extension unit
VM6 / SM6

GEM

Connection unit
right / left outgoing
line

GBM

52
52

Annex
Functions required by private networks
Incoming cable connection unit

GAM 2

02-2005

Incoming cable - connection


unit (with SF6 earthing switch)

GAM

53
53

Annex
Functions required by private networks
Disconnector unit

SM

02-2005

MV / LV
transformer unit
for auxiliaries

TM

Earthing busbars
compartment

EMB

54
54

Annex
Functions required by private networks
Busbars power supply for main incoming line on
right or left and cables for standby line

NSM busbars

02-2005

NSM cables

55
55

Annex
Optimum performance

02-2005

56
56

Annex
General characteristics

02-2005

57
57

Annex
Endurance

02-2005

58
58

Annex
Operating mechanisms

02-2005

59
59

Annex
Easy installation
Simplified civil works
Symetric cable
connection
Identical cubicles heights
and floor - level depths

02-2005

60
60

Potrebbero piacerti anche