All about
DVC (Damodar Valley
Corporation)is a legacy to
DVC
the people of India, emerged as a culmination of
attempts made over a whole century to control
the wild and erratic Damodar river. The river
spans over an area of 24,235 km2 covering the
states of Jharkhand (Dhanbad, Bokaro,
Hazaribagh, Koderma, Giridih, Chhatra, Palamau,
Rachi, Lohardaga and Doomka) & West Bengal
(Burdwan , Hooghly, Howrah, Bankura and
Purulia).
Objectives:
The objectives at the time of its inceptions are:
Flood control
Promotion and operation of schemes for irrigation
Water supply for industrial and domestic use
Navigation and drainage
Generation, transmission and distribution of electrical
energy
Promotion of forestation and control of soil erosion in
valley area
Promotion of public health,
agriculture,industrial,economic and general well-being
in Damodar Valley
Training at:
Maithon Hydel power station
Kalyaneshwari substation
Central load dispatch
Maithon Hydel
Power station
Generator specificatons
20 Mw Generator Specification
1. Simmens Sehuckert,Germany
2. 3PH,generator no.D73445
3. Type-PFL 670/47-34
4. Y11,000 volt,1310/1525amp
5. RPM-176.6
6. KVA-25000/29000
7. P.F-0.8 const.
Excitor Specification
1. V: 295/330/445
2. A: 465/505/700
Main Excitor
1. DC GEN. NO-D39408
2. TYPE-GV 441/36
3. V-310,333,500
4. RPM-176.6
MEJIA THERMAL
POWER STATION
General layout of
Thermal Power Station
Boilers
Boiler is an enclosed vessel in which water is
heated and circulated until the water is turned
in to steam at the required pressure
Types of boilers are:
Fire tube boilers
Water tube boilers
Reheaters
Superheaters
FD fan
ctrostatic precipitator(ES
High voltage electrodes attract the ash and flue
gas particles.
At regular intervals, the electrodes are struck
with hammers to throw off the ash particles.
This is used to clean up the flue gas or smoke
sent up the chimney.
Economizer
The economizer draws the heat out of the flue
gas and uses it for heating the feed water
It is placed in the passage of flue gases in
between the exit from the boiler and the entry
to the chimney.
It saves the coal combustion, increases steam
rate and improves boiler efficiency.
Cooling Towers
The condensate (water) formed in the condenser
after condensation is initially at high temperature.
This hot water is passed to cooling towers.
It is a tower- or building-like device in which
atmospheric air (the heat receiver) circulates in
direct or indirect contact with warmer water (the
heat source) and the water is thereby cooled.
Types Of Cooling Tower Wet cooling tower
Dry cooling tower
Electric Substation
What is a Substation?
Asubstationis a part of an electricalgeneration,
transmission, anddistributionsystem. Substations
transformvoltagefrom high to low, or the reverse,
or perform any of several other important
functions. Between the generating station and
consumer, electric power may flow through several
substations at different voltage levels.
Substations may be owned and operated by an
electrical utility, or may be owned by a large
industrial or commercial customer. Generally
substations are unattended, relying onSCADAfor
remote supervision and control.
Single-line Diagram of
alyaneshwari Sub-statio
AUTOTRANSFORMERS:
OUTDOOR
SWITCHYARD
BUSBARS
POWER TRANSFORMERS AND MEASUREMENT TRANSFORMERS
INSULATORS
CIRCUIT-BEAKERS & ISOLATORS
LIGHTNING ARRESTORS
GALVANISED STEEL STRUCTURES FOR TOWERS & EQUIPMENT SUPPORTS.
ROADS, RAILWAY TRACK, CABLE TRENCHES
PLCC EQUIPMENT INCLUDING LINE TRAP, TUNING UNIT, COUPLING CAPACITOR, ETC.
STATION EARTHING SYSTEM COMPRISING GROUND MAT, RISERS, AUXILIARY MAT,
EARTHING STRIPS, EARTHING SPIKES & EARTH ELECTRODES.
CONTROL CABLES FOR PROTECTION AND CONTROL
INCOMING & OUTGOING LINES
CONTROL BUILDING
IN EVERY SUB-STATION CERTAIN SUPERVISION, CONTROL AND PROTECTION FUNCTIONS
ARE NECESSARY. SO A CONTROL BUILDING/CONTROL ROOM IS REQUIRED. THE RELAY
AND PROTECTION PANELS AND CONTROL PANELS ARE INSTALLED IN THE CONTROL
ROOM.
CONTROL IN SUB-STATION ARE OF TWO CATEGORIES.
INSULATION 70/170KV
QTY OF OIL/WT. 20 LTR./ 24 KG APRX.
DYNAMIC CURRENT 65.6 KAP
YEAR 1999
TOTAL WT. 150 KGS (APRX)
MAX. TEMP. RISE - WINDING - 45C
INSULATION A
OVER AMBIENT (45C) OIL - 40C
CONTINUOUS THERMAL CURRENT 780 A
Circuit Breakers:
MAIN FUNCTION OF CIRCUIT BREAKER IS TO SWITCH OFF AND SWITCH ON
THE NORMAL CURRENT AND TOP TRIP THE CIRCUIT AT THE OCCURANCE OF
ANY FAULT.
Isolators:
ISOLATORS GIVE PHYSICAL SEPARATION BETWEEN LIVE
PART AND DEAD PART. PHYSICAL SEPARATION CAN BE
SEEN BY NAKED EYE FROM A DISTANCE.
Bus bars:
Switch Gear
A switchgear includes all the switching devices
It includes all devices associated with control,
metering and regulating of electrical power
system.