Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Series 20
Specific
protection
50BF
S 20
S 23
3I + I0
10 I / 8 O
1 com. port
T 20
M 20
T 23
B 21
B 22
3 V + V0
81R
Series 40
3I + I0
10 I / 8 O
3V
1 com. port
Logical equations
67et 67N
S 40
S 41
S 42
67N
S 80
S 81
67N
Series 80 3I + 2xI0
3V + V0
42 I / 23 O
2 com. port
Logical equations
LOGIPAM
2x3I + 2xI0
3 V + V0
3I + 2xI0
2x3V + V0
3I + I0
4unbalance I
3V + V0
67et 67N
37P et 81R
87 T
87 M
S 82
S 84
T 40
G 40
M 41
T 42
B 80
T 81
M 81
G 82
T 82
T 87
M 88
M 87
G 88
G 87
B 83
C 86
Tools
Situate SEPAM
protection relays
A
Software
General introduction
Tools
Data sheets
Series 20
Series 40
Series 80
Project managers
Description of the main
characteristics:
Selection table
Wiring diagrams
Modularity principle
Commercial catalogue
Series 10
Commercial catalogue
Series 20
Series 40
Series 80
Sales engineers
1 Selection guide
2 & 3 for each series
General presentation and
selection table
Concise description of metering,
protection, control logic and
communication functions.
Wiring diagram and general
characteristics
5 Order forms
Sepam Offer EN 2007_01.ppt
8
User manuals
Series 10
User manuals
Series 20
Series 40
User manuals
Series 80
Manual 3
Presents Modbus communication
tables
Sepam Offer EN 2007_01.ppt
11
DNP3 communication
Series 20
Series 40
Series 80
General introduction
Situate SEPAM
protection relays
A
Software
General introduction
Tools
Series 80
Then add
connectors :
Application :
Working language :
Manuals :
CCA630 connector
The CCA630 connector is used to
connect 3 phase current
transformers to Sepam
contain interposing ring CTs with
through primaries
Can be disconnected with the power
on since disconnection does not
open the CT secondary circuit.
CCA634 connector
The CCA634 adds an input for a
residual current transformer :
do not connect a core balance ct
do not use bases Io input
contain interposing ring CTs with
through primaries
can be disconnected with the power
on since disconnection does not
open the CT secondary circuit.
Series 20
Series 40
3 models of modules
MES 114
voltage on inputs
24 to 250 V DC
MES 114 E
voltage on inputs
110 to 250 V DC
110 V AC
MES 114 F
voltage on inputs
220 to 250 V DC
220 to 240 V AC
How to choice :
- general case, without immunity constraint Vcc:
- auxiliary supply : 100 or 110V
Vcc ou Vca
- auxiliary supply >200V
Vcc ou Vca
MES114
MES114E
MES114F
Sepam Offer EN 2007_01.ppt
23
Series 80
14 logic inputs
6 output relays
3 models of modules
MES 120
voltage on inputs
24 to 250 V DC
MES 120 G
voltage on inputs
220 to 250 V DC
MES 120 H
voltage on inputs
110 to 250 V DC
3 modules maximum
Maximum configuration:
How to choice :
- general case, without immunity constraint Vcc
- auxiliary supply 100 or 110V
Vcc
- auxiliary supply >200V
Vcc
42 inputs (3 x 14)
23 outputs (3 x 6 + 5)
MES120
MES120H
MES120G
Sepam Offer EN 2007_01.ppt
24
Cable
1st module
Cable
3rd mod.
Series 20
CCA772
MSA141
CCA770
MET148-2
CCA774
DSM303
Series 40
CCA772
MSA141
CA770
MET148-2
CCA774
DSM303
Series 40
CCA772
MSA141
CCA770
MET148-2
CCA772
MET148-2
Series 40
CCA772
MET148-2
CCA770
MET148-2
CCA774
DSM303
2 chains of modules
Base unit
Cable
1st module
Cable
2nd module
Cable
3rd mod.
CCA774
DSM303
Chain 1
D1
CCA772
MET148-2
CCA770
MET148-2
Chain 2
D2
CCA772
MSA141
CCA785
MCS025
control of the CB
dated events and trip currents
reading of the currents
reset of the protections
Modbus interfaces
ACE949-2:
2-wire RS 485
ACE959:
4-wire RS 485
ACE937: Fiber optic
Number of interfaces
that can be connected:
Series 20: 1
Series 40: 1
Series 80: 2
Interfaces:
ACE969-TP
S-LAN
ACE969-FO
2-wire RS 485
Fiber optic
E-LAN
2-wire RS 485
MODBUS
Number of interfaces
Series 20: 1
Series 40: 1
Series 80: 2
Sepam Offer EN 2007_01.ppt
33
S-LAN
E-LAN
Series 20
Series 40
Series 80
S20 >V0526
S40 >V3.00
Software
Situate SEPAM
protection relays
A
Software
General introduction
Tools
Selection guide
Series 20
Series 40
Series 80
SFT2841
Series 20
Series 40
Series 80
Windows environment
On-line help available
Comes in 3 languages,
and may also be
customized
For commissioning, the
SFT2841 tool is
useful for Series 20
recommended for Series
40
essential for Series 80
SFT2826
Series 20
Series 40
Series 80
Selection of analog
channels displayed
Selection of logic data
displayed
2 cursors to measure
differences
Possibility of zooming
on a zone of the graph
SFTSAV
Series 20
Series 40
Series 80
SFT2840
Series 20
Series 40
Series 80
SFT2842
Series 20
Series 40
Series 80
Loading of the
application in Sepam
Loading of language
files in Sepam
SFT2885
Series 80
SFT2887
Series 80
No software
Series 10
Situate SEPAM
protection relays
A
Software
General introduction
Tools
Incomer protection
Detection of short-circuits and overloads on busbars
Without voltage monitoring
50/51 : maxi I 50N/51N : maxi I0
46 : unbalance
(50BF : breaker failure)
Incomer protection
Detection of short-circuits and overloads on busbars
Underpower disconnection
function 37P
disconnection of the network if the
power drawn by the load can be
supplied by the generator
Feeder protection
Detection of short-circuits and overloads on the line
Without voltage monitoring
50/51 : maxi I 50N/51N : maxi I0
(50BF : breaker failure)
79 : re-closer
Transformer protection
Detection of short-circuits and overloads
Detection of internal faults, Thermostat or Buchholz
Temperature monitoring by RTD
Without voltage monitoring
50/51 : maxi I 50N/51N : maxi I0
(50BF : Breaker failure)
46 : unbalance
49RMS : thermal overload
38/49T : temp monitoring
26/63 : thermostat / bucholz ( DGPT2 DMCR)
Transformer protection
Fast detection of short-circuits in the transformer
Transformer protection
Isolation of faulty section and different sources in parallel
when applicable
Same
source
Different
sources
Motor protection
Detection of internal faults
Detection of power supply faults
Detection of load-related faults
Temperature monitoring by RTD
Without voltage monitoring
50/51 : maxi I 50N/51N : maxi I0 37 : undercurrent
46 : unbalance
49RMS : thermal overload
38/49T : temp monitoring
48 / 51LR / 14 : excessive starting time / locked rotor
66 : starts per hour
Motor protection
Fast detection of short-circuits in the motor
Generator protection
Detection of internal faults
Detection of network faults
Detection of driving machine-related faults
Temperature monitoring by RTD
Monitoring of voltages and frequency
Isolated generator
Coupled generator
Detection of short-circuits on generator side by
directional protection 67
Restricted earth fault differential 64REF
Sepam Offer EN 2007_01.ppt
59
Generator protection
Fast detection of short-circuits in the generator