ABSTRACT
Recently, converter topologies employing a high frequency transformer in order to
reduce size &weight .
The trade-off between high efficiency &low cost is a hard task for these architectures
because they require several power stages .
In low power applications - International standards recommends the use of grid
connected power converters without any galvanic isolation.
Transformer less architectures in low power distributed systems are recommended
The proposed work is a novel five level converter topologies that are used in
PV CELL based single phase grid connected converters.
Simulation of these topologies are carried out by using MATLAB/Simulink.
OBJECTIVES:
OBJECTIVES:
1.
1.
PRESENTATION
PRESENTATION
INTRODUCTION
OUTLINE
INTRODUCTION
OUTLINE
CONCLUSION
INTRODUCTION
INTRODUCTION cont
PV SYSTEM
TRANSFORME
R
POWER
CONVERTER
POWER GRID
Benefits
: Safety , leakage current reduction, no dc current injected in to the grid.
Drawbacks : Large size, heavy weight , expensive and overall conversion efficiency
PV
system
MLI
Power
grid
6
INTRODUCTION cont
H5 TOPOLOGY
INTRODUCTION cont
H6 TOPOLOGY
S1
S2
S3
S4
S5
vm
VOLTAGE
LEVEL
S1
S2
S3
S4
S5
Vdc
Vdc/2
-Vdc/2
-Vdc
0
10
11
vm
S6
S1
S2
S3
S4
voltage
level
Vdc
S1
S2
S3
S4
S5
S6
Vdc/2
-Vdc/2
-Vdc
12
13
Output
voltage
of
H5
topology
At fs =15KHz;
Vs=380V;
R=1000;
M=0.87
Output
voltage
of
H6
topolog
y
14
15
GRID CONNECTED
MLI TOPOLOGIES
16
General hybrid multi level inverter connects to the single phase grid:
A.C voltage source act as a grid with required nominal voltage of 230V and 50 Hz frequency.
The filter must be designed precisely.
To reduce the voltage distortions when delivers to the load
To stabilize the energy output
To achieve sinusoidal shape and precise value.
17
H(j)=
H(j)=(R/L) where =2*pi*f;=damping factor:
By substituting 2=(R/L);; (2)=(1/RC) are in the above equation then,
H(j)=1-j(1/2)
| H(j)|=
When the increase then magnitude | H(j)| decreases .If phase angle increase while damping decrease.
In time domain If <1 that causes under damping
If >1that causes over damping and
If =1 that causes critical damping .
But when =(1/)=0.707 ,then the filter circuit act as low pass filter .
18
value
1 mH
Filtering capacitor(Cf)
2 F
0.5
Grid impedance(Zg)
The own design of the filter is a compromise between the value of the capacitance and
inductance.
The high capacitor has positive effects on the voltage quality.
The higher inductance value is required to achieve demanded cut-off frequency of the filter.
It is second order filter and it has better damping behaviors than L -filter
The output filter reduces the harmonics.
19
converter output
voltage waveform
THD before filter
is 33.86%
converter output
voltage waveform
THD after filter
is 0.95%
20
converter output
voltage waveform
THD before filter
is 34.70%
converter output
voltage waveform
THD after filter
is 1.10%
21
After filter
[Vo]
Fundamental
%THD
334.2V
32.86
[Vg]
Fundamental
327.2V
%THD
0.95
After filter
[Vo]
[Vg]
Fundamental
%THD
Fundamental
331.8V
34.70
328.8V
%THD
1.10
22
PV-GRID CONNECTED
MLI TOPOLOGIES
23
H5-Topology
or
H6-Topology
24
(1)
(2)
(3)
Vpv=-Rs*Ipv(4)
25
26
Grid Voltage
[Vg]
Parasitic capacitor
voltage
[Vp]
Leakage current
[iL]
Fundamental
%THD
Fundamental
%THD
H5
333.1V
32.99
328.4V
1.00
608.7V
1.1100A
H6
329.9V
33.59
328.5V
0.98
334.2V
0.4459A
and
28
29
S5 and S6 configurations providing the same voltage VMP to the full bridge rails. In
(a), the HS capacitor is discharging, and in (b), the LS capacitor is discharging.
30
CHS = CLS = C
DC capacitor circuit employed for the analytical
analysis of the Voltage Balancing
31
32
33
SIMULATION RESULTS
34
Results cont..
Converter output
voltage (Vo)
THD =17.12%
35
Results cont..
parasitic capacitor
voltage
(Vp)=-160.5V
36
Results cont..
leakage current
iL=0.04682A
1.2
leakage current
1
0.8
0.6
1.11
0.4
0.44
0.2
0
H5(open loop)
H6(open loop)
0.04
H6(closed loop)
37
Results cont..
Inverter
Grid Voltage
Parasitic
Leakage Mid-
Output Voltage
[Vg]
capacitor
current
voltage
[iL]
[Vo]
Fundamental %THD Fundamental %THD
328.8V
17.91
328V
0.75
[Vp]
-160.5V
point
voltage
[Vmp]
0.04682A 160.5V
38
CONCLUSIONS
From the table it can be concluded that parasitic capacitance is
greatly reduced which can reduce the voltage stress on the
switching devices.
It is also concluded that the leakage current is also greatly
reduce from 1.11A to 0.04682A.
Because of reduction in the leakage current grid performance is
improve to the 0.75% of THD.
From above conclusion it can be stated that H6 topology is
recamended for the transformer-less PV GRID system.
39
THANK YOU