RSU
CSN
2 Types
CSN MA
CSN MM
CSN MA
1 BASE RACK (1K)
Up To 3 Extension Racks
(1.25k)
BASE RACK
EXTENSION RACK
T
C
R
M
T
TOND
TOND
UCX0 UCX1
GTA
CNL OR ICNE
CNL OR ICNE
T
C
R
M
T
CNL OR ICNE
T
C
R
M
T
CNL OR ICNE
T
C
R
M
T
CNL OR ICNE
CNL OR ICNE
T
C
R
M
T
CNL OR ICNE
CNL OR ICNE
T
C
R
M
T
CNL OR ICNE
T
C
R
M
T
T
C
R
M
T
T
C
R
M
T
EXTENSION RACKS
TOND
TOND
INTERFACE WITH
EXCHANGE
UCX0 UCX1
CNL
CNL
CNL
ICNE
GTA
TBALAM
T
C
R
M
T
TBUCN
T
C
R
M
T
TBABM2
T
C
R
M
T
TBABM2
T
C
R
M
T
TBABM2
T
C
R
M
T
TB A B M 2
IN CASE OF CSNL
TCILR
T
B
A
L
A
M
T
B
U
C
N
TOND 80 (0)
~ 40 V
T
C
C
O
B
TOND 80 (1)
~40 V
T
C
C
S
T
C
C
S
T
P
U
C
B
T
M
U
C
2
M
T T
MR
Q C
R X
T
R
C
X
T
R
C
X T
S
U
C
T
R
C
X
T
R
C
X
T
R
C
X
TCBTL
T
T
R
S
13 12 9 8 5 4
T
T
R
S
15 14 11 10 7 6
T
T
R
S
1
T
T
R
S
3
T
M
Q
R
T
H
L
R
T
M
U
C
2
M
T
P
U
C
B
T
C
C
S
T
C
C
S
T
H
L
R
T
T
R
S
0
T
T
R
S
2
T
R
F
8
B
UCX0
UCX1
T
B
T
D
T
B
T
D
T
C
R
M
T
B A
T
R
F
8
B
T
F
I
L
M
B
* *
GTA
T
P
O
S
T
C
R
M
T
T
M
L
A
B
T
S
U
R
V
2
T
S
U
R
V
2
T
S
U
R
V
2
T
5
V
1
7
T
5
V
1
7
T
S
U
R
V
2
T
C
R
M
T
UCN SHELF
UCX
TSUC
PIL 0
PIL 1
FLOG0
FLOG1
VISU INFO
0
1
TSUC Board
Pilot lights:
PIL0 on
: Logic unit 0 is pilot
PIL 1 on
: lLogic unit 1 is pilot
FLOG0 on
: Logic unit 0 is faulty
FLOG 1 on
: Logic unit 1 is faulty
INFO 0 to INFO 3
: Not used
Notes : During operation, either the PIL0 or PIL1 pilot LED is on
Switches and push buttons
VBASC
VBASC
RZG
RZGL0
RZL1
LED
Push Button
Switch
RZG
: Overall resetting
RZL0
RZL1
CSN EXTENSION
RACK
LOCALSUBSS.
CONCENTRATOR
CNL
CNL
REMOTE
SUBS.
CONN.
CNE
CNL
CNL
PCM
ICNE
REMOTESUBSS.
CONCENTRATOR
INTERFACE
T TTT
A AAA
B BBB
A AAA
CN
TT TT
P H HA
OL L B
LR RA
TT
AC
BR
AM
T
CN SHELF
NE Distribution
BASE RACK
EXTENSION RACK 1
RINGER, PS
NE=8-1 < 8- NE=9-0 < 9127
127
UCX
GTA
NE=0-1 <
0-127
NE=1-0 <
1-127
NE=10-1 <
10-127
NE=11-0 <
11-127
NE=2-1 <
2-127
NE=3-0 <
3-127
NE=12-1 <
12-127
NE=13-0 <
13-127
NE=4-1 <
4-127
NE=5-0 <
5-127
NE=14-1 <
14-127
NE=15-0 <
15-127
NE=6-1 <
6-127
NE=7-0 <
7-127
NE=16-1 <
18-127
NE=17-0 <
17-127
Meaning
Permanently off
Permanently on
ON 200 ms OFF 2
sec
On 200 msec
OFF 200 msec
ON 200 msec
OFF 200 msec
TPOL
TMABS Board
TMABS Board
TMABE Board
B B B B TCRMT
B ->
V
TSURV2
C
V ->
V
T5V17
UCN
CN0
CN1
CN2
CN3
R
BBBBB
CN
CN
CN
CN
CN
EXT
EXT
EXT
CC
1 2
UCX GTA
C
3
C7 + C8
C
8
C12 + C13
C
13
C17 + C18
C
18
C3 + C4
C
4
C8 + C9
C
9
C13 + C14
C
14
C18 + C19
C
19
C4 + C5
C
5
C9 + C10
C
10
C14 + C15
C
15
C19 + C20
C
20
C5 + C6
C
6
C10 + C11
C
11
C15 + C16
C
16
C20 + C21
C
21
C6 + C7
C
7
C11 + C12
C
12
C16 + C22
C
17
C21 + C17
C
22
Alarm Indication in
TPOS Board
DSL Indicate status of Board. When
Board is operational the LED willbe
flashing (200ms ON, 200ms OFF)
LED-6 When there is any Alarm, will
be on.
LED1-5 All 5 LEDs are Permanently
glowing ,
when there is no Alarm
When there is any Alarm LED1-5
shows Alarm number (LED-5 MSB)
In the event of simultaneous
alarms, their numbers are displayed,
in turn of 3 second intervels
Important Alarm
Numbers
0 = FIRE
3 = AC
12 = RECTIFIER
24 = CONVERTOR
(TCRMT/TSURV2/T5V17)
25 = INVERTOR (TOND80)
27 = CUT OFF POWER
CSN MM RACK
UCN
CNL
CNL
CNL
CNL
CNL
CNL
CNL
CNL
T
C
R
M
T1
T
P
U
C
D
T
C
C
S
C
T
C
R
C
X
T
C
S
U
C
T
C
R
C
X
T
C
C
S
C
T
P
U
C
D
T
C
T
R
S
T
C
T
R
S
T
C
B
T
X
T
C
B
T
X
T
R
F
B
C
T TF
R IL
F8 M
C C
T
C
P
O
S
B
T
M
L
A
C
T
C
H
L
R
T
C
H
L
R
T T T
C C C
R R O
M M N
T1 T1 D
T
C
O
N
D
T
C
P
O
L
X
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
CN i+1
T
A
B
A
T
A
B
A
T
A
B
A
T
T T
T T
C
A A
A A
R
B B
B B
M
A A
A A
T1
i= 0,2,4,6 etc.,
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
A
B
A
T
C
P
O
L
X
CSN MM NE
Distribution
UCN
NE=0-1 < NE=1-0 NE=2-1 < NE=3-0 <
0-127
< 1-127
2-127
3-127
NE=4-1 < NE=5-0 NE=6-1 < NE=7-0 <
4-127
< 5-127
6-127
7-127
NE=8-1 < NE=9-0 NE=10-1 NE=11-0
8-127
< 9-127 < 10-127 < 11-127
NE=12-1 NE=13-0 NE=14-1 NE=15-0
< 12-127 < 13-127 < 14-127 < 15-127
LINE CHARACTERISTICS
Standard line characteristics
Impedance :
subscriber on hook
LINE CHARACTERISTICS
Power supply :
voltage : - 54 v on wire a, 0 v
on wire b,
speech current : between 19
mA and 60
mA
A.c. voltage
wire "a
A.c. voltage
wire "b
DC voltage
wire "a
DC voltage
wire "b"
L5 Insulation of
wire "a" / Ground
L6 Insulation of
wire "b" / Ground
L7 Insulation of
wire "a" / wire
"b
L8 Continuity :
wire "a" / wire
"b"
@ESAB:
CEN=1/15-10-22/14 H 42 MN 26/TEST ON
@ND=2523700:
PROCESSING TELDMS ACC
ND=
2523700 NE=001-13-063 NROB=129
L1=
0
V
L2=
0
V
L5> 1016
KO
L6> 1016
KO
PROCESSING TELDMS EXC
@PH=A:
PROCESSING TELDMS ACC
CALL ND :
2523700
ENTER NDOP
PROCESSING TELDMS EXC
@NDOP=2526000:
PROCESSING TELDMS ACC
PROCESSING TELDMS EXC
@PH=RP13:
PROCESSING TELDMS ACC
P13 R = 0036
MA
MAX = 0036
MA
MIN = 0036
MA
MOY = 0036
MA
PROCESSING TELDMS EXC
A SUBSCRIBER LINE
TY=GABA1+KLA STATUS=LIBR
L3=
0.0 V
L4=
0.0 V
L7> 1016
KO
L8=
2.60 MI
@PH=P13:
PROCESSING TELDMS ACC
P13 R =
0037
MA
0650
OHM
Test procedure
1
Unhook and dial the DERAL (127162)
)
Reception of the DERAL connection tone.
2
Hang up
)
250 ms after hang-up, the insulation resistances are
measured :
between wire a and the Ground, compared with reference
R1,
between wire b and the Ground, compared with reference
R2,
between wires a and b, compared with reference R3.
3
Unhook (without waiting for a ring) :
)
The measurement results are sent in the form of ringing
tones for 20 to 40 seconds :
the tone is continuous if :
measured R1 > reference R1, Rl = R2 = 100 Kohm : t 10%,
measured R2 > reference R2,
measured R3 > reference R3, R3 set at 30, 50, 70, 90, 100
4
Hang up :
)
A timed ringing current is sent for 2 minutes
5
Unhook :
)
The microphone current is measured and compared to
two references I1 and I2.
The measurement result is sent back in the form of
pulse tones for 20 to 40 seconds :
continuous tone if : I1 < measured I < I2, I1=32 mA,
I2=50 mA,
slow pulsing (or scrambled) tone if : measured I < I1,
quick pulsing tone if : measured I > I2.
6
Hang up
)
Release.
LIST OF STATUS
FXA : Subscriber in
permanent loop condition or
looped line.
FAUT : Presence of a
diagnostic on the subscriber
equipment
BLOS: Blocked by the system
(isolated subscriber board or
isolated CN).
CN
UT
EQ
Line
FXA
Set
FXA
THANK YOU