DeviceNet IntelliCENTER on

CENTERLINE MCCs

Rev 5058-CO900B

Copyright 2012 Rockwell Automation, Inc. All rights reserved.

Agenda
IntelliCENTERTechnology
Technology
IntelliCENTER
WhatisisDeviceNet?
DeviceNet?
What
IntelligentMotor
MotorControls
Controls
Intelligent
Software
Software
Summary
Summary

Copyright 2012 Rockwell Automation, Inc. All rights reserved.2

IntelliCENTER Technology Overview

IntelliCENTER Technology continues to be an essential


differentiator for the CENTERLINE family of MCCs
Copyright 2012 Rockwell Automation, Inc. All rights reserved.3

Value of IntelliCENTER Technology


Faster Integration
Network is preconfigured (node number, baud rates,
functionality verified)
Faster installation compared to hardwired I/O
Control and diagnostics
State of the art Intelligent Motor Controls provide
crucial feedback from motors
Precise control with intelligent motor control devices
Wide array of device level components
More information where you need it when you need it
Enhances your plant asset management system
Improved uptime
Warnings in advance of failure
Troubleshooting tools and information at your
fingertips
Copyright 2012 Rockwell Automation, Inc. All rights reserved.

IntelliCENTER
Integrated Intelligence within LV and MV MCCs
Provides comprehensive look into LV & MV
MCCs

Real-time monitoring
Access from anywhere in the facility
Complete documentation and MCC history

DeviceNet products provide:

Predictive Maintenance, Process Monitoring, and


Advanced Diagnostics

Bulletin 2100 or 2500 LV MCC

Simplified DeviceNet LV & MV MCC design


and installation

Ease of moving and adding units


Prevents accidental damage to DeviceNet cables

Plug & Play system

Pre-tested and pre-configured

Bulletin 1500 or 1900 MV MCC


Copyright 2012 Rockwell Automation, Inc. All rights reserved.5

Agenda
IntelliCENTERTechnology
Technology
IntelliCENTER
WhatisisDeviceNet?
DeviceNet?
What
IntelligentMotor
MotorControls
Controls
Intelligent
Software
Software
Summary
Summary

Copyright 2012 Rockwell Automation, Inc. All rights reserved.6

What is DeviceNet?
Established MCC Network
Simple, open networking
solution based on the
producer/consumer model.
Provides superior real time
control, data exchange,
configuration capabilities,
and collection of data at
regular intervals or on
demand.
Ideally suited for MCC
applications with respect to
cost and performance.

Copyright 2011 Rockwell Automation, Inc. All rights reserved.

Full Featured
Reduce programming time
and errors with automatic
tag generation
Network configuration is
completed and tested prior
to shipping in order to
ensure quality
Automatic Device
Replacement ensures a
device will return to its
prior level of configuration
without having to use a
software tool.

Easy to Maintain
Easy to manage with
enhanced remote access
Maximize maintainability
without sacrificing control
efficiency or information
access & visibility
Proven reliable for over 15
years

Copyright 2012 Rockwell Automation, Inc. All rights reserved.

DeviceNet Layout
DeviceNet cables/ports located
in vertical wireway of MCC

Pull-apart connectors
Simplified installation,
relocation, and adding of units
Superior to traditional daisychaining, where downstream
equipment may unintentionally
be shut-down

Trunk Line

Daisy Chain

Easy to install in the field

All nodes are preconfigured


with the IntelliCENTER
database pre-built at the factory

Copyright 2012 Rockwell Automation, Inc. All rights reserved.8

DeviceNet Layout

IntelliCENTER LV MCC Line-up

Built-in DeviceNet
Plug-in DeviceNet cable

LV

LV

MV

MV

LV

MV

IntelliCENTER MV MCC Line-up

Copyright 2012 Rockwell Automation, Inc. All rights reserved.9

Benefits of DeviceNet
DeviceNet Wiring:
Installed and tested prior to shipping
Prevents damage which may occur during field installation
Class 1 provides electric isolation without requiring cable spacing
Simpler than traditional hard-wiring
DeviceNet Network settings are configured and saved.
.DNT provided on IntelliCENTER Software disk
Automatic Device Replacement (ADR)
Speedily returns device to prior level of configuration
DeviceNet Tag Generator
Descriptive tags for devices
Reduce system integration time

Full functionality is tested prior to shipping.


Copyright 2012 Rockwell Automation, Inc. All rights reserved.10

Agenda
IntelliCENTERTechnology
Technology
IntelliCENTER
WhatisisDeviceNet?
DeviceNet?
What
IntelligentMotor
MotorControls
Controls
Intelligent
Software
Software
Summary
Summary

Copyright 2012 Rockwell Automation, Inc. All rights reserved.11

Intelligent Motor Control Components


PowerFlex 753 Drive
General purpose Variable Frequency Drive
3 option slots for communications, safety, feedback and additional I/O
Features predictive diagnostics, and Safe Torque-Off and Safe Speed Monitor options
PowerFlex 40 Drive
Full featured component class drive
Closed loop control for either speed or position feedback for improved speed
Increased power loss ride through
SMC Flex Soft Starter
Modular and compact soft starter
Includes I/O, electronic overload, integral bypass
Copyright 2011 Rockwell Automation, Inc. All rights reserved.

Copyright 2012 Rockwell Automation, Inc. All rights reserved.

Intelligent Motor Control Components


E3 Plus Overload Relay
Enhanced thermal overload motor protection with inherent phase loss, temperature,
ground fault, voltage monitoring, and underload protection
Advanced motor diagnostic information to assist with preventative maintenance
programs resulting in reduced downtime
E1 Plus Overload Relay
Includes two discrete inputs and one output relay for monitoring and control of
motor starter related I/O
Enhanced motor protection with overload, jam trip and underload warning functions
DeviceNet System Accessory (DSA)
Interface module for non-intelligent devices
Device Logix
Copyright 2011 Rockwell Automation, Inc. All rights reserved.

Copyright 2012 Rockwell Automation, Inc. All rights reserved.

Agenda
IntelliCENTERTechnology
Technology
IntelliCENTER
WhatisisDeviceNet?
DeviceNet?
What
IntelligentMotor
MotorControls
Controls
Intelligent
Software
Software
Summary
Summary

Copyright 2012 Rockwell Automation, Inc. All rights reserved.14

IntelliCENTER
Software Highlights- Virtualization of MCC
Access information from any
remote location on the network
Identify and diagnose issues
while avoiding shut downs
Simplifies troubleshooting
Decrease maintenance and
operation costs
Remote configure parameters

Copyright 2012 Rockwell Automation, Inc. All rights reserved.

15

IntelliCENTER
Software Highlights - Documentation
Digital copies of electrical and
mechanical drawings
Easy to add custom drawings

Never search for missing


manuals again
Enhanced Plant Asset
Management
Copyright 2012 Rockwell Automation, Inc. All rights reserved.

16

IntelliCENTER
Software Highlights-ActiveX Features
Easy integration of IntelliCENTER screens FactoryTalk View and onmachine HMIs
Made possible by ActiveX controls in IntelliCENTER software
Reduces HMI development time and provides the user more information
MCC Elevation View

Unit Monitor View

Electronic User Manuals

Electronic CAD Diagrams


Spreadsheet View of MCC

Copyright 2012 Rockwell Automation, Inc. All rights reserved.17

IntelliCENTER Energy
IntelliCENTER Energy is a fusion of
FactoryTalk EnergyMetrix and all
features currently in IntelliCENTER
IntelliCENTER Energy will offer:
Real-time energy consumption
and historical trending down to
the device level
Preconfigured setup of devices in
FactoryTalk EnergyMetrix
Ability to monitor and manage
energy usage for huge cost
savings
Copyright 2012 Rockwell Automation, Inc. All rights reserved.18

Agenda
IntelliCENTERTechnology
Technology
IntelliCENTER
WhatisisDeviceNet?
DeviceNet?
What
IntelligentMotor
MotorControls
Controls
Intelligent
Software
Software
Summary
Summary

Copyright 2012 Rockwell Automation, Inc. All rights reserved.19

IntelliCENTER
What You Get
Faster installation compared to hardwired I/O
System configuration and testing done at the factory
Nodes addressed
DeviceNet powered up
Component communication and functionality verified
Increased precise control with intelligent motor control devices
Enhanced Plant Asset Management System: Information where &when you need it
Increased uptime
Warnings of failure in advance
Troubleshooting tools and information at your fingertips

Lower Cost of Ownership!


Copyright 2012 Rockwell Automation, Inc. All rights reserved.20

IntelliCENTER
Complete Management of LV & MV MCCs
Real-time display of MCC data and information
Remote troubleshooting without total system shutdown
Complete system documentation
Optimized software performance

Polling algorithm segregates monitoring and control, so monitoring scans do


not affect control scans

Complements operator interface and product specific software such


as DriveTools and FactoryTalk EnergyMetrix

Copyright 2012 Rockwell Automation, Inc. All rights reserved.21

Questions?

Follow ROKAutomation on Facebook & Twitter.


Connect with us on LinkedIn.
www.rockwellautomation.com
Rev 5058-CO900B

Copyright 2012 Rockwell Automation, Inc. All rights reserved.

22

Potrebbero piacerti anche