Sei sulla pagina 1di 58

SGSN9810 Gb

Interface Data
Configuration
www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

References

3GPP TS 48.014

SGSN9810 Operation Manual Data Configuration


Volume I(V8.60)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Contents
1.

Basic Concept

2.

Gb over FR

3.

Gb over IP

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Gb Interface

Gb interface is the interface between SGSN and


PCU

Gb interface is a mandatory interface in the GPRS


network

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Gb Interface Protocol Stack __ User


Plane

The Gb interface protocol stack is composed of SNDCP,


LLC, BSSGP, NS, L1bis.

Application
IP

IP
Relay

SNDCP

SNDCP

LLC

LLC
Relay

GTP-U

GTP-U

UDP

UDP

IP

IP

RLC

RLC

BSSGP

BSSGP

MAC

MAC

Network
Service

Network
Service

L2

L2

GSM RF

GSM RF

L1bis

L1bis

L1

L1

MS

Um

BSS

Gb

SGSN

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Gn

GGSN

Gi

Gb Interface Protocol Stack __Control


Plane

The Gb interface protocol stack is composed of


GMM/SM, LLC, BSSGP, NS, L1bis.

GMM/SM

GMM/SM

LLC

LLC
Relay

RLC

RLC

MAC

MAC

GSM RF

MS

Um

BSSGP

BSSGP

Network
Service
GSM RF L1bis

Network
Service
L1bis

BSS

Gb

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

2G-SGSN

The Relevant Hardware For Gb


Over FR

The Gb protocol stack is processed by the UGBI, UEPC, UFEU


and UEPI

E1 acts as its physical connection that is extended from UEPI

UFEU performs the Frame Relay function

UEPC is an optional pinch board that can provide the


encryption and compression function

UGBI performs the NS, BSSGP, LLC ,SNDCP and GMM/SM


functions

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Concept of Gb Over FR

E1

E1 is the physical cable connecting BSS with SGSN. BSS can connect
with SGSN either directly or through the intermediate FR network.

BC

BC is the bearer channel of frame relay, corresponding to the timeslot


group of E1/T1

The whole E1/T1 line can be either configured as one BC, or divided into
multiple BCs. But its better to configure as many timeslots as possible
in one BC.

For easy local management, BCs are distinguished by numbers, which


are called BCID (BC Identification).

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

E1 and BC
E1 link
TS0~TS31

BC1(TS1~TS3)

SGSN
BSS

BC1(TS1~TS3)
TS1
TS2
TS3

NSVE 1
NSVC2

TS4
TS5

NSVE 3
NSVC4

TS6

BC2(TS4~TS6)

E1 link
TS0~TS31

BC2(TS1~TS3)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

NSVC

NS-VC

NS-VC is the virtual link provided by NS layer for BSSGP


layer through which NS transmits the data of BSSGP
layer

NS-VC is identified by NS-VCI, which is unique in SGSN

NS-VC in SGSN corresponds to NS-VC in BSS one by one,


and their IDs are the same

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Concept Of Gb Over FR

PVC

PVC refers to the permanent virtual connection of the


frame relay.

In one BC, a PVC is differentiated from others by its


number, which is called DLCI (Data Link Connection ID).

In SGSN9810, each NSVC link is corresponding to one


FR link.

The command ADD NSVC is used to add a NSVC link


and FR link simultaneously.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

NSE

NSE

Network service entity (NSE) is identified by NSEI, its ID


must as same as the PCU configuration.

NSE manages a group of NS-VCs, and corresponding a


group of cells.

The Sub-network layer can be realized by FR protocol or


IP link.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

BVC

BVC

BSSGP virtual connection is used in the BSSGP layer.

There are three kinds of BVC: Sig (signaling) BVC, PTP


(point to point) BVC and PTM (point to multipoint) BVC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Network Service Entities


NSEI-1

BV C I 1

B
S
C

BV C I 2
3

BV
CI
4

CI
V
B

Gb

(BVCI
1-4)

SGSN
)
I 5-8
C
V
(B

BV C I 5

BS
C

BVCI 6

NSEI-2

B
VC
I8

7
CI
V
B

BVC = BVCI + NSEI

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Relationship Between BVC,CELL


And NSE

Cells correspond to PTP BVCs one by one. One cell


is only subordinating to one NSE, but one NSE
include multiple CELLs

A Sig BVC manages a group of cells in a NSE. NSE


and Sig BVC is one to one correspondence. So one
Sig BVC manages multi PTP BVC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Gb Over IP
LLC
RE L AY
BSSGP

RL C

BSSGP

M AC

NS

NS

L1

L1

BSS

Gb

SGSN

The 3GPP protocol specifies that the


Sub-NS uses the FR network or IP
network as its bearer mode

Network Service

Network Service Control /


Network Service Control protocol

Sub-Network Service /
Sub-Network Service protocol

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

The Relevant Hardware For Gb Over


IP

The Gb protocol stack is processed by the UGBI.

The UFEU and UEPI need not configure in case Gb


over IP

The UDP and IP layer are realized by UGFU board.

The UPIU and its pinch board UEEC or UEFC provide


the physical port for Gb interface to connect with PCU.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Concept Of Gb Over IP

IPNSVC:

In the Gb over IP network, each NS-VC link is identified


by a quaternary group including the following:

1 IP address of the SGSN

2 UDP port number of the SGSN

3 IP address of the BSS

4 UDP port number of the BSS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Contents
1.

Basic Concept

2.

Gb over FR

3.

Gb over IP

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Data Planning Rules


The NSEI must be consistent
with the PCU. It must be unique
within the SGSN.
The NSVC ID must be consistent
with the PCU. It must be unique
within the SGSN.
The DLCI must be consistent with
the peer node. It must be unique
within the BC.
The BCID must be unique on an
E1/T1 port. It need not be
consistent with that of the peer
end.

NSE
1:N
NSVC

NSVC

NSVC

NSVC

DLCI

DLCI

DLCI

BC

BC

1:1
DLCI
N:1
BC
N:1
E1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

E1

Gb Interface Networking
NSEI=1
0/0

0/1

0/2

U
G
B
I

U
G
B
I

U
G
B
I

U
E
P
I

U
E
P
I

Port
TS=1-10,DLCI=100, NEVCI=11
01
,
100
Port
=
I
C
, DL 12
0
1
12
CI =
S=1
T

Port
03

BSS1

Port TS=1-10,DLCI=100, NEVCI=22


1

460010001010002
460010001010003

NEV

TS=
1-10
,D
NEV LCI=100
CI=2
,
1

460010001010001

460010002010001

BSS2

460010002010002
460010002010003

NSEI=2

U
E
P
I

SGSN

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Network Data
Link

Subra

Slo

Port

No.

ck No

No

BCID Time DLCI NSVC NSE BSSID


slot

100

11

BSS1

100

21

BSS2

No
1

1~1
0

4~2
0

1~9

100

12

BSS1

2~1

100

22

BSS2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Configuration Step
Step

Action

Command

Add the relation


boards

ADD BRD

configure the
information of E1
link

ADD
UEPIUTPICFG

Add the E1/T1


ports.

ADD E1T1CFG

Add the BCs.

ADD BC

Add the NS-VCs.

ADD NSVC

Add the NSEs.

ADD NSE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 1: Add The Relative


Boards
ADD BRD:

For the Gb over TDM, UEPI, UGBI,UFEU should be added.

UEPC is used to encrypt and compress the data, it


should be added depending on the real network

UGBI board woke in N+1 mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 1: Add The Relevant


Boards
ADD BRD:

Example:

ADD BRD: SRN=0, SN=0, BP=IO, BT=UGBI, RS=ACTIVE,


PSRN=0, PSN=2, PMCDT=UFEU, SPEC=B, BCKBT=UEPI,
BCKST=ACTIVE;

ADD BRD: SRN=0, SN=1, BP=IO, BT=UGBI, RS=ACTIVE,


PSRN=0, PSN=2, PMCDT=UFEU, SPEC=B, BCKBT=UEPI,
BCKST=ACTIVE;

ADD BRD: SRN=0, SN=2, BP=IO, BT=UGBI, RS=STANDBY,


PMCDT=UFEU, SPEC=B, BCKBT=UEPI, BCKST=STANDBY;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 2: Configure E1
Workmode
ADD UEPIUTPICFG:

This command is used to configure the E1/T1 clock mode and


the work mode

Example:

ADD UEPIUTPICFG: SRN=0, SN=0, CL=SL, BT=UFEU_Plus,


BM=UNBALANCE;

ADD UEPIUTPICFG: SRN=0, SN=1, CL=SL, BT=UFEU_Plus,


BM=UNBALANCE;

ADD UEPIUTPICFG: SRN=0, SN=2, CL=SL, BT=UFEU_Plus,


BM=UNBALANCE;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 3: Configure E1 Port

ADD E1T1CFG:

This command is used to define the information of the port.

Example:

ADD E1T1CFG: SRN=0, SN=0, PN=0, LKFRMT=DF, LKCT=HDB3;

ADD E1T1CFG: SRN=0, SN=0, PN=1, LKFRMT=DF, LKCT=HDB3;

ADD E1T1CFG: SRN=0, SN=1, PN=0, LKFRMT=DF, LKCT=HDB3;

ADD E1T1CFG: SRN=0, SN=1, PN=1, LKFRMT=DF, LKCT=HDB3;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 4: Configure The BC

ADD BC :

This command is used to define BC.

Example:

ADD BC: SRN=0, SN=0, PN=0, BCID=0, BTS=1, ETS=10,


DLCIT=1, PROTOCOL=Q933, BWCNTL=NO, MODE=DCE;
ADD BC: SRN=0, SN=0, PN=1, BCID=0, BTS=4, ETS=20,
DLCIT=1, PROTOCOL=Q933, BWCNTL=NO, MODE=DCE;
ADD BC: SRN=0, SN=1, PN=0, BCID=0, BTS=1, ETS=9,
DLCIT=1, PROTOCOL=Q933, BWCNTL=NO, MODE=DCE;
ADD BC: SRN=0, SN=1, PN=1, BCID=0, BTS=2, ETS=17,
DLCIT=1, PROTOCOL=Q933, BWCNTL=NO, MODE=DCE;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

DTE/DCE
Scenario 1

BSS

SGSN
BC

Scenario 2

DCE

DTE

DTE

DCE

BSS

FR

SGSN

DTE

FR

DTE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 5: Configure The NSVC

ADD NSVC:

This command is used to define NSVC.

Example:

ADD NSVC: OTHERNODE="to BSS1", NSVCI=11, NSEI=1, SRN=0,


SN=0, PN=0, BCID=0, DLCI=100;
ADD NSVC: OTHERNODE="to BSS2", NSVCI=21, NSEI=2, SRN=0,
SN=0, PN=1, BCID=0, DLCI=100;
ADD NSVC: OTHERNODE="to BSS1", NSVCI=12, NSEI=1, SRN=0,
SN=1, PN=0, BCID=0, DLCI=100;
ADD NSVC: OTHERNODE="to BSS2", NSVCI=22, NSEI=2, SRN=0,
SN=1, PN=1, BCID=0, DLCI=100;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 6: Configure The NSE

ADD NSE:

This command is used to define NSE.

Example:

ADD NSE: OTHERNODE="to BSS1", NSEI=1, SRN=0,


SN=0, BSSID=1;

ADD NSE: OTHERNODE="to BSS2", NSEI=2, SRN=0,


SN=1, BSSID=2;
NSE
~ Negotiated with PCU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Contents
1.

Basic Concept

2.

Gb over FR

3.

Gb over IP

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

PCU1

Case

PCU2

IP of PCU1

IP of PCU2

10.20.20.1:3322

10.20.30.1:2244/

/10.20.20.2:3323

IP network

10.20.30.2:2245

Router

IP of router: 10.30.30.3
DATA

UGFU

PCU IP

UPIU

UPIU

UFCU

UGFU

IP of UPIU:10.30.30.1/10.30.30.2

IP
User data and Control
signaling

IP of UGFU: 10.10.10.1/10.10.11.2
UDP port: 3344, 3345
IPVlink
Logical IP
Ethernet Port
IP route
IPVLINK
UGBI

URCU/UBIU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Slot Number of the Boards

Board Subrack

Slot

Active/stand
by

Back
board

PMCU PMCDW
P
N

UGBI

UGBI

UGFU

10

UPIU

UEEC

UGFU

12

UPIU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

UEEC

UAIC
UAIC

IP Parameter
Data type

IP port and address


of PCU

IP address of SGSN
(UPIU port)

Data item

value

Peer IP address, Port


of PCU1

10.20.20.1:3322

Peer IP address, Port


of PCU1

10.20.20.2:3323

Peer IP address, Port


of PCU2

10.20.30.1:2244

Peer IP address, Port


of PCU2

10.20.30.2:2245

Port(3/10/1)

10.30.30.1

Port(3/11/1)
Port(3/12/1)

10.30.30.2

Port(3/13/1)
IP address of Gb
interface logical IP)
(UGFU IP for Gb)

UGFU(3/10)

10.10.10.1

UGFU(3/11)
UGFU(3/12)

10.10.11.2

UGFU(3/13)
UDP port for UGBI

UGBI(0/0)

3344

UGBI(0/1)

3345

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

IP NSVC
IP NSVC1

UGBI(0/0)

IP NSVC2
IP NSVC3

UGBI(0/1)

PCU1
(NSEI=1)

IP NSVC4

IP NSVC5

UGBI(0/0)

IP NSVC6
IP NSVC7

UGBI(0/1)

IP NSVC8

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

PCU2
(NSEI=2)

IP NSVC Data
IP NSVC

NSEI

NSVCI

UGBI

LINK

SGSN IP

SGSN

(UGFU)

PORT

PCU IP

PCU
PORT

11

0/0

10.10.10.1

3344

10.20.20.1

3322

12

0/0

10.10.11.2

3344

10.20.20.2

3323

13

0/1

10.10.10.1

3345

10.20.20.1

3322

14

0/1

10.10.11.2

3345

10.20.20.2

3323

21

0/0

10.10.10.1

3344

10.20.30.1

2244

22

0/0

10.10.11.2

3344

10.20.30.2

2245

23

0/1

10.10.10.1

3345

10.20.30.1

2244

24

0/1

10.10.11.2

3345

10.20.30.2

2245

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

IPVLNK
IPVLNK1

UGBI(0/0)

UGFU(3/10)
IPVLNK2

UDP Port 3344 for UGBI(0/0);

10.10.10.1

IPVLNK3

UGBI(0/1)

IPVLNK4

UDP Port 3345 for


UGBI(0/1);

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

UGFU(3/12)

10.10.11.2

IPVLNK

IPVLNK

IP virtual link

It is an internal communication channel established


between UGBI and UGFU

Identify

Each IPVLNK is identified by (IP, Port; slot of UGBI)

Each IPVLNK will binding with a specific UGBI board. The


banding ensure the system forward the data between a
UGFU and UGBI.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

IPVLNK
IP VLNK

UGBI

UGFU IP

UDP PORT

0/0

10.10.10.1

3344

0/0

10.10.11.2

3344

0/1

10.10.10.1

3345

0/1

10.10.11.2

3345

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Configuration Steps
Step

Action

Command

1. Configure the related boards.


1

Add the UGBI

ADD BRD

Add the UGFU and UPIU


boards

ADD BRD

2. Configure the IP routes.


3

Set the work mode

SET UPIU_PORT

Configure the public


network segments.

ADD PUBNWIP

Configure IP addresses for


board interfaces.

ADD IFIP

Configure the static


routes.

ADD IPRT

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Configuration Steps
Step

Action

Command

3. Configure the Gb interface.


7

Configure the IP address


for the Gb interface.

ADD BRDIP

Add the IP virtual


links.

ADD IPVLNK

Add the NS-VCs.

ADD IPNSVC

10

Add the IP endpoint


weight for the Gb
interface.

ADD GBIPEWEIGHT

11

Add the signaling


entities.

ADD NSE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 1: Add UGBI Board

ADD BRD

This command is used to add UGBI boards

If it is Gb over IP, the UFEU and UEPI need not be configured

Example

ADD BRD: SRN=0, SN=0, BP=IO, BT=UGBI, RS=ACTIVE,


SPEC=B;

ADD BRD: SRN=0, SN=1, BP=IO, BT=UGBI, RS=ACTIVE,


SPEC=B;

ADD BRD: SRN=0, SN=2, BP=IO, BT=UGBI, RS=STANDBY,


SPEC=B;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 2: Add UGFU Board

ADD BRD

This command is used to add UGFU and the related


boards for Gb IP data forwarding.

This boards should be configured when configure Gn


interface

The IP address configured in this command is the IP


address of Iu interface and Gn interface. For the IP
address of Gb, will be configured by ADD BRDIP
command.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 3: Set Work Mode

SET UPIU_PORT

Ethernet port of UPIU board can work in 1+1 mode or internal UGFU
communication mode

In this case, 1+1 mode should be chosen for these two Ethernet ports

Example

SET UPIU_PORT: MSRN=3, MSN=10, MPN=1, SSN=11, SPN=1, PT=EETH,


WM=MS, ND=TRUE;

SET UPIU_PORT: MSRN=3, MSN=12, MPN=1, SSN=13, SPN=1, PT=EETH,


WM=MS, ND=TRUE;
WM
~ MS master and slave mode
~ UC internal communication mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 4:Configure Public IP Segment Of


UPIU

ADD PUBNWIP

This command is used to configure the public network


IP for UPIU that make the IP of UPIU can be in the same
subnetwork

Example

ADD PUBNWIP: IP="10.30.30.0", MSK="255.255.255.0";


Router

IP
~ Public network segment

Same subnetwork

UPIU

UPIU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 5:Configure IP Address Of


UPIU

ADD IFIP

This command is used to configure the IP for UPIU

Example

ADD IFIP: SRN=3, SN=10, PN=1, IP="10.30.30.1",


MSK="255.255.255.0", DESC="For Gb";

ADD IFIP: SRN=3, SN=12, PN=1, IP="10.30.30.2",


MSK="255.255.255.0", DESC="For Gb";
IP
~ IP address of UPIU physical Port

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 6:Configure IP Route

ADD IPRT

This command is used to configure the IP route for UPIU

Example

ADD IPRT: IP=10.0.0.0", MSK=255.0.0.0",


GATE="10.30.30.3";
GATE
~ The routers IP address

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 7:Configure Gbs IP


Address
ADD BRDIP

This command is used to configure the IP address

for Gb interface
Example

ADD BRDIP: SRN=3, SN=10, IPT=IPV4, IPV4="10.10.10.1";

ADD BRDIP: SRN=3, SN=12, IPT=IPV4, IPV4="10.10.11.2";


IPV4
~ It is a logical IP configured in UGFU board
~ It is the IP address of Gb over IP

DATA

UGFU IP

PCU IP

PCU

DATA

PCU IP

UGFU IP

PCU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 8:Configure IPVLNK

ADD IPVLNK

This command is used to configure IPVLNK to binding a UGBI


board with a UGFU board.

After the binding, all packet data of a specific UGBI board will
process and forward by the corresponding UGFU board.

Example IPVLINK for UGBI (0/0)

ADD IPVLNK: HSRN=3, HSN=10, IPT=IPV4, IPV4="10.10.10.1",


PT=UDP, LPN=3344, SVT=GB, SSRN=0, SSN=0;

ADD IPVLNK: HSRN=3, HSN=12, IPT=IPV4, IPV4="10.10.11.2",


PT=UDP, LPN=3344, SVT=GB, SSRN=0, SSN=0;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 8:Configure IPVLNK

ADD IPVLNK

Example IPVLINK for UGBI (0/1)

ADD IPVLNK: HSRN=3, HSN=10, IPT=IPV4, IPV4="10.10.10.1",


PT=UDP, LPN=3345, SVT=GB, SSRN=0, SSN=1;

ADD IPVLNK: HSRN=3, HSN=12, IPT=IPV4, IPV4="10.10.11.2",


PT=UDP, LPN=3345, SVT=GB, SSRN=0, SSN=1;
IPV4
~ The IP address of UGFU
~ This IPVLNK is identified by (IP, Port, Slot of UGBI)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 9:Configure IP NSVC

ADD IPNSVC:

This command is used to add a NSVC link

The link is identified by vector

(SGSN IP, Port; PCU IP, Port)

We can configure several IP NSVC for one NSE.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 9:Configure IP NSVC

ADD IPNSVC:

Example configure 4 NSVC to PCU1

ADD IPNSVC: OTHERNODE="TO bss1", NSVCI=11, NSEI=1, SRN=0, SN=0,


IPT=IPV4, LIPV4="10.10.10.1", LUP=3344, RIPV4="10.20.20.1", RUP=3322;

ADD IPNSVC: OTHERNODE="TO bss1", NSVCI=12, NSEI=1, SRN=0, SN=0,


IPT=IPV4, LIPV4="10.10.11.2", LUP=3344, RIPV4="10.20.20.2", RUP=3323;

ADD IPNSVC: OTHERNODE="TO bss1", NSVCI=13, NSEI=1, SRN=0, SN=1,


IPT=IPV4, LIPV4="10.10.10.1", LUP=3345, RIPV4="10.20.20.1", RUP=3322;

ADD IPNSVC: OTHERNODE="TO bss1", NSVCI=14, NSEI=1, SRN=0, SN=1,


IPT=IPV4, LIPV4="10.10.11.2", LUP=3345, RIPV4="10.20.20.2", RUP=3323;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 9:Configure IP NSVC

ADD IPNSVC:

Example configure 4 NSVC to PCU2

ADD IPNSVC: OTHERNODE="TO bss2", NSVCI=21, NSEI=2, SRN=0, SN=0,


IPT=IPV4, LIPV4="10.10.10.1", LUP=3344, RIPV4="10.20.30.1", RUP=2244;

ADD IPNSVC: OTHERNODE="TO bss2", NSVCI=22, NSEI=2, SRN=0, SN=0,


IPT=IPV4, LIPV4="10.10.11.2", LUP=3344, RIPV4="10.20.30.2", RUP=2245;

ADD IPNSVC: OTHERNODE="TO bss2", NSVCI=23, NSEI=2, SRN=0, SN=1,


IPT=IPV4, LIPV4="10.10.10.1", LUP=3345, RIPV4="10.20.30.1", RUP=2244;

ADD IPNSVC: OTHERNODE="TO bss2", NSVCI=24, NSEI=2, SRN=0, SN=1,


IPT=IPV4, LIPV4="10.10.11.2", LUP=3345, RIPV4="10.20.30.2", RUP=2245;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 10:Configure Load Weight

ADD GBIPEWEIGHT :

This command is used to configure weigh for each PCU

The load weight is based on the IP endpoint, not the NSVC

Example configure the weight for PCU 1

ADD GBIPEWEIGHT: IPT=IPV4, RIPV4="10.20.20.1",


RUP=3322, NSEI=1, DW=200, SW=200;

ADD GBIPEWEIGHT: IPT=IPV4, RIPV4="10.20.20.2",


RUP=3323, NSEI=1, DW=100, SW=100;

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

DW=200

DW=100

SW=200

SW=100

Step 10:Configure Load Weight

ADD GBIPEWEIGHT :

Example configure the weight for PCU 2

ADD GBIPEWEIGHT: IPT=IPV4, RIPV4="10.20.30.1",


RUP=2244, NSEI=2, DW=200, SW=200;

ADD GBIPEWEIGHT: IPT=IPV4, RIPV4="10.20.30.2",


RUP=2245, NSEI=2, DW=100, SW=100;
RIPV4/RUP
DW
SW

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Step 11:Configure NSE

ADD NSE:

This command is used to add a NSE

Each NSE contain several NSVC link

Example add a NSE for PCU 1

ADD NSE: OTHERNODE="TO bss1", NSEI=1, SRN=0, SN=0,


BSSID=1, BT=IP ;

Example add a NSE for PCU 2

ADD NSE: OTHERNODE="TO bss2", NSEI=2, SRN=0, SN=1,


BSSID=2, BT=IP;
NSE
BT

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Thank you
www.huawei.com

Potrebbero piacerti anche