Sei sulla pagina 1di 90

BSC6000

Hardware Structure
www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Foreword

This course describes the hardware structure of the


HUAWEI BSC6000 system, board module functions,
system operating principles, system signal flows,
and O&M flows. In addition, this course describes the
principles of hardware configuration and lists some
typical configurations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page2

References

HUAWEI BSC6000 Hardware Reference

HUAWEI BSC6000 System Description

HUAWEI BSC6000 Architecture and Principles

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page3

Objectives

Upon completion of this course, you will be able to:

Understand HUAWEI BSC6000 function and features

Master HUAWEI BSC6000 hardware structure

Understand HUAWEI BSC6000 system principle

Master HUAWEI BSC6000 typical configuration

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page4

Contents
1.

System Description

2.

Hardware Structure

3.

System Logical Structure

4.

System Signal Flow

5.

Typical Configuration

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page5

Contents
1.

System Description

2.

Hardware Structure

3.

System Logical Structure

4.

System Signal Flow

5.

Typical Configuration

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page6

Location of the BSC6000

The HUAWEI BSC6000 is a new generation GSM BSC


product after the HUAWEI BSC32 (previous BSC)
HLR

MSC
BTS

MS

A
BTS

MS

Gs

BSC6000

Pb

PCU6000
Gb

BTS

MS

Um

GGSN

SGSN

PDN

Abis

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page7

Features of the BSC6000 System

Large capacity, high integration

Supporting 2048TRX at the full rate; supporting 2048TRX


at the half rate

Maximum of traffic: 13,000 Erl; BHCA : 2,340,000

In case of using the E1 interface board, the maximum of


the system is four cabinets

In case of using the STM-1 interface board, the maximum


of the system is three cabinets

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page8

Features of the BSC6000


System
Low cost, low power consumption

256TRX power consumption( including GTCS)

1640W (A interface in E1 mode)

1570W (A interface in STM-1 mode)

2048TRX power consumption( including GTCS)

6920W (A interface in E1 mode)

5620W (A interface in STM-1 mode)

Flexible configuration

Supporting multiple types of networking between BSC and BTS

Multiple clock sources

Flex Abis

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page9

Features of the BSC6000


System
Advanced management algorithm for radio resource

HW_II Power Control Algorithm

HW_II Handover Algorithm: supporting about 10


handover algorithms, such as hierarchical handover,
layer handover, and PBGT handover

Multiple radio resource allocation technology and


flexible radio channel switch mechanism

Support internal GOMU board

Support local exchange and MML function

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page10

Features of the BSC6000


System
Smooth capacity expansion and upgrade

Supporting smooth, in-service capacity expansion

Supporting in-service patching

High performance, advanced design

Supporting 2M signaling link

Supporting local multiple signaling points (at most 4)

Supporting TC resource pool

Supporting full-index report performance statistics

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page11

Contents
1.

System Description

2.

Hardware Structure

3.

System Logical Structure

4.

System Signal Flow

5.

Typical Configuration

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page12

Contents
2.

Hardware Structure
2.1 Rack
2.2 Subrack
2.3 Board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page13

Structure of Rack

Model: Huawei N68-22 cabinet

Dimension: 600mm (width) x800mm


(depth) x 2200mm (height)

Weight: 150 kgs of Empty cabinet; 350


kgs of full configuration

BSC6000 rack type

GBCR: GSM BSC Control Processing Rack

GBSR: GSM BSC Service Processing Rack

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page14

GBCR

Power
distribution
box

GBCR (GSM BSC Control Processing


Rack ) must be configured with

GMPS (GSM main processing subrack)

GBAM (GSM Back Administration Module)

Cabling
subrack
Air defence
subrack

GIMS( GSM Integrated Management


System )

One KVM (keyboard, video and mouse)

One LAN Switch

Subrack
GIMS
KVM

One GBAM (GSM Back Administration


Module) server

LAN Switch

GBAM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page15

GBSR

GBSR (GSM BSC Service


Processing Rack ): It is only
configured with subracks

Subrack

One service rack can be


configured with three
Subrack

subracks at most according


to the requirement

Subrack

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page16

GBAM

The GBAM is a server installed with Linux system and


OMU software, which is used to perform operation and
maintenance for the BSC6000

Controls the communications between the LMT and boards

Processes commands from the LMT

Filters the results from boards and then returns the results
to the LMT

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page17

GBAM Module Port

CD-ROM
Power button

Display port

RJ45
RJ45NIC
NIC port

RJ45 NICadaptive

10M/100M
Ethernet port

Port for the


mouse and
keyboard

RJ45 Serial port

Grounding
screw

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

DC input power socket

Page18

KVM

The KVM is a device


integrating a keyboard, a
monitor, and a mouse. It is
the operating platform of the
GBAM

Port for mouse cable

Port for display cable

Port for keyboard


cable

Power switch

DC input power socket

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page19

Fan Box

PFCU (Fan Control Unit)

Monitors the running status of the fans in the fan box

Reports the working status of the fan box to GSCU

Detects the temperature of the fan box with a temperature sensor

Shows the current status of fan box and alarms through LED

PFPU (Fan Power Unit)

provides power supply for nine fans

keeps the voltage stable

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page20

Power Distribution Box

Checks two channels of - 48 V input voltage

Detects one route of external temperature sensor; detects


one route of external humidity sensor; detects two lightning
protection components; detects the status of six
distributed-power output switches

Reports the status of the power distribution box and


exchanges O&M information with the GSCU

Emits audio and visual alarms

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page21

Subrack
Fan box

The width of subrack is 19

Board

inches

A backplane is in the middle


of the subrack, and boards are
Cabling
Trough

inserted from the front and


the rear of the subrack

Both the front subrack and the

Front of subrack

rear subrack provide 14 slots

Numbered as 00 --13 from left


to right at the front

Numbered as 14--27 from right


to left at the back

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page22

Rear of subrack

Subrack

GMPS/GEPS

BTS
Abis

MSC

GTCS
A

Ater

BM
Pb

PCU

TC

GBAM
Cb

CBC

LMT

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page23

Abbreviation
Abbreviation

Full Name

GBAM

GSM Back Administration Module

GEPS

GSM Extended Processing Subrack

GMPS

GSM Main Processing Subrack

GTCS

GSM TransCoder Subrack

LMT

Local Maintenance Terminal

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page24

SubrackGMPS

MPS: It performs the basic service processing and


operation maintenance functions. In addition, it
provides system clock. The GMPS is configured in the
GBCR. Compared with the GEPS subrack, the GMPS
also is configured with the GGCU board.

It can process the services of a maximum of 512


TRXs in full configuration.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page25

SubrackGMPS

Rear boards

14

15

16

17

18

19

20

21

22

23

24

25

26

27

14

15

16

17

18

19

G
E
I
U
P

G
E
I
U
P

G
E
I
U
T

G
E
I
U
T

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
P

G
E
I
U
P

G
E
I
U
T

G
E
I
U
T

G
E
I
U
B

G
E
I
U
B

G
X
P
U
M

G
X
P
U
M

G
T
N
U

G
T
N
U

G
G
N
U

G
G
N
U

G
X
P
U
T

G
X
P
U
T

G
G
C
U

G
G
C
U

G
X
P
U
M

G
X
P
U
M

G
T
N
U

G
T
N
U

G
G
N
U

G
G
N
U

G
X
P
U
T

G
X
P
U
T

00

01

04

05

06

07

08

09

12

13

00

01

04

05

06

07

08

09

20

21

22

23

G
O
M
U

G
O
M
U

24

25

26

27

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
G
C
U

G
G
C
U

12

13

backplane

Front boards

02

03

10

Configuration Type A

11

02

03

10

11

Configuration Type B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page26

GEPS

Performs basic service processing

0 ~3 GEPSs can be configured in GBCR or GBSR

Processes a maximum of 512 TRXs in full


configuration
14 15
Rear board

G
E
I
U
P

G
E
I
U
P

G
X
P
U
M

G
X
P
U
M

00

01

16

17

18

19

20

21

22

23

24

25

26

27

G
E
I
U
T

G
E
I
U
T

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
E
I
U
B

G
T
N
U

G
T
N
U

G
S
C
U

G
S
C
U

G
X
P
U
T

G
X
P
U
T

04

05

06

07

08

09

10

11

12

13

Backplane

Front board

02

03

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page27

GTCS-E1 Transmission

Performs transcoding, rate adaptation and submultiplexing

Provides a maximum of 3,840 speech channels when


A interface adopts E1 transmission
14

15

Rear board

16

17

18

19

20

21

22

23

24

25

26

27

G
E
I
U
T

G
E
I
U
T

G
E
I
U
A

G
E
I
U
A

G
E
I
U
A

G
E
I
U
A

G
E
I
U
A

G
E
I
U
A

G
E
I
U
A

G
E
I
U
A

G
T
N
U

G
T
N
U

G
S
C
U

G
S
C
U

G
D
P
U
C

G
D
P
U
C

G
D
P
U
C

G
D
P
U
C

G
D
P
U
C

04

05

06

07

09

10

11

12

13

Backplane

Front board
00

01

02

03

08

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page28

GTCS-Optical Transmission

Performs transcoding, rate adaptation and submultiplexing

Provides a maximum of 7,560 speech channels when


A interface adopts STM-1 transmission
Rear board

14

15

16

17

18

G
E
I
U
T

G
E
I
U
T

G
E
I
U
T

G
E
I
U
T

G
D
P
U
C

G
D
P
U
C

G
D
P
U
C

G
T
N
U

01

02

03

04

19

20

21

22

23

24

25

26

27

G
O
I
U
A

G
O
I
U
A

G
O
I
U
A

G
O
I
U
A

G
O
I
U
A

G
O
I
U
A

G
O
I
U
A

G
O
I
U
A

G
T
N
U

G
S
C
U

G
S
C
U

G
D
P
U
C

G
D
P
U
C

G
D
P
U
C

G
D
P
U
C

G
D
P
U
C

G
D
P
U
C

05

06

07

08

09

10

11

12

13

Backplane

Front board
00

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page29

GTCS
Front board
The GTNU Slot 4-5
The GSCU Slot 6-7
The GDPUC Slot 9-13

Real board

The GEIUA Slot 18-27


The GEIUT Slot 14-17

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page30

Abbreviation
Abbreviation

Full name

GGCU

GSM General Clock Unit

GSCU

GSM GE switching Network Unit

GTNU

GSM TDM Switching Unit

GXPUT

GSM extensible Processing Unit for


Transmission

GXPUM

GSM Extended Processing Unit for Main service

GDPUC

GSM Data Processing Unit for CS service

GEIUA

GSM E1/T1 Interface Unit for A

GEIUB

GSM E1/T1 Interface Unit for Abis

GEIUP

GSM E1/T1 Interface Unit for Pb

GEIUT

GSM E1/T1 Interface Unit for Ater

GOIUA

GSM Optic Interface Unit for A

GOIUB

GSM Optic Interface Unit for Abis

GOIUP

GSM Optic Interface Unit for Pb

GOIUT

GSM Optic Interface Unit for Ater

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page31

Board- GGCU

Configured in slots 12 and 13 in the GMPS (active/standby mode)

provides synchronous timing signals for the system

Generates synchronous clock signals

Keeps the consistency of synchronization information output

GGCU

RUN
ALM
ACT
ATN-IN
0
1

from the active and standby GGCUs

CLKOUT

4
5

Port

6
7

CLKOUT 0-9

Output 8 kHz clock signals to the


GSCU

RJ45

COM 0-1

Reserved

RJ45

8
9
COM0

TESTIN
CLKLIN1

PARC

CLKLIN0 TESTOUT

COM1

Matching
Connector

Function

TESTOUT

Reserved

TESTIN

Reserved

CLKIN 0-1

Synchronization clock signal input


port, used to input one route of
external 2.048 MHz signal and 2.048
Mbit/s code stream signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page32

SMB male
connector

Board- GSCU

GGSU

Configured slots 6 and 7 of the GMPS/GEPS/GTCS


(active/standby mode)

RUN
ALM
ACT

Performs maintenance management

Provides a GE platform for the subrack

Provides clock information for the other boards in the same

RESET
LINK
ACT

0
1
2

subrack except the GGCU in the GMPS

3
LINK
ACT

5
6

10/100/1000BASE-T

Port

Matching

Function

Connector

7
LINK
ACT

8
9
10

CLKIN

DEBUG

11

TESTOUT

PARC

10/100/1000 10/100/1000 Mbit/s Ethernet ports, used to connect


subracks
BASE-T 09
10/100/1000 Mbit/s Ethernet ports, used to connect
RJ45
10/100/1000
GBAM (Only the main subrack is connected with the
BASE-T 1011
GBAM)
COM
Debugging port
Clock source port, used to receive the 8 kHz clock
CLKIN
signals from the panel of the GGCU
TESTOUT
Clock test signal port, used to output clock test SMB male
signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page33

Board- GTNU
GTNU

Configured in slots 4 and slot 5 of the


GMPS/GEPS/GTCS (active/standby mode)

RUN
ALM
ACT

TN M 5 TN M 4 TN M 3TN M 2 TN M 1 TN M 0

Performs the TDM (Time Division Multiplexing)


switching function

Provides 128 K *128 K TDM switching

Allocates TDM network resources, establishes and


releases radio links
Matching
Port

Function
connector

TDM 0-5

TDM high-speed serial port, used to


connect the GTNUs between subracks

PARC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page34

DB14

Board- GXPUM

GXPU

Configured in slots 0 and 1 of the GMPS/GEPS


(active/standby mode).

RUN
ALM

LINK
ACT

1 0 /1 0 0 /1 0 0 0 B A S E -T

ACT

Voice call control

Packet service control

Handover

Power control

Paging control

System information management

Channel assignment

BTS common service management

Matching

1
2
3

Port
10/100/1000
BASEs- T0-3

Function

connector

GE/FE Ethernet port, reserved

PARC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page35

RJ45

Board- GXPUT

GXPU

Configured in slots 10 and slot 11 in the GMPS/GEPS


(active/standby mode)

RUN
ALM
ACT

Performs message cell broadcast function of the system

Provides interface for connecting the Cell Broadcast Center


(CBC)

Stores cell broadcast messages

Schedules cell broadcast messages based on the Cell

1 0 /1 0 0 /1 0 0 0 B A S E -T

Broadcast Channel (CBCH)


LINK
ACT

0
1
2

Matching

Port
10/100/1000
PARC

BASEs T0-3

Function

connector

GE/FE Ethernet port, reserved

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page36

RJ45

Board- GEIU/ GOIU


GEIU

GOIU

RUN
ALM
ACT

RUN
ALM
ACT

TX

GEIU/GOIU works in active/standby mode and can be


categorized into the following types :

The GEIUB/GOIUB is the Interface Unit for the Abis interface

The GEIUP/GOIUP is the Interface Unit for the Pb interface

The GEIUT/GOIUT is the Interface Unit for the Ater interface

The GEIUA/GOIUA is the Interface Unit for the A interface

RX
E1/T1(24~31)

LOS

E1/T1(16~23)

Interface

E1/T1(8~15)

E1/ T1
0-31

Function
The E1/ T1 port,0 ~31 of the used to
transmit and receive E1/ T1 signals on
routes 0-31

PARC

TESTOUT2M1 2M0

TESTOUT2M1 2M0

E1/T1(0~7)

2M 0-1

2.048 MHz clock source output port,


used to output the extracted line clock
as the system clock source

PARC

2.048 MHz clock output port, used to


output the testing clock of
the system
Page37

Copyright 2006 HuaweiTESTOUT


Technologies Co., Ltd. All rights reserved.

Matching
connecto
r
DB44

SMB
male
connecto
r
SMB
male
connecto

Board- GEIU/ GOIU


GEIU

GOIU

The GEIU/GOIU has the following functions:

RUN
ALM
ACT

RUN
ALM
ACT

TX
RX

E1/T1(24~31)

LOS

Processes the SS7 MTP2 protocols (performed by GEIUT/GOIUT)


Processes the Link Access Procedure on the D channel (LAPD)
protocols (performed by GEIUP/GOIUP or GEIUB/GOIUB )
Provides maintenance links when GTCS subracks are configured
at the MSC side
Performs inter-board Tributary Protect Switching (TPS)

E1/T1(16~23)

Interface

Matching
connecto
r

Function

E1/T1(8~15)

PARC

TESTOUT2M1 2M0

TESTOUT2M1 2M0

E1/T1(0~7)

PARC

RX

Transmitting optical port

155.52 Mbit/s

TX

Receiving optical port

155.52 Mbit/s

2M 0-1

TESTOUT

LC
connector

2.048 MHz clock source output port, used


to output the extracted line clock as the
system clock source

SMB male
connector

2.048 MHz clock output port, used to


output the testing clock of the system

SMB male
connector

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page38

Board- GEIU

There are DIP switches on GEIU, the default setting is to


support
75
DIP
Bit Description
switc
h
S1

75

120

0 -7 of the Used to select the impedance on


E1/ T1 links 7

ON

OFF

8 -15 of the Used to select the impedance on


E1/ T1 links 15

ON

OFF

16 -23 of the Used to select the impedance


on E1/ T1 links 23

ON

OFF

24 -31 of the Used to select the impedance


on E1/ T1 links 31

ON

OFF

58

Unused

ON

OFF

S3

18

0 -7 of the Used to set the protection


grounding of the transmitting end of E1/ T1
links 7

ON

OFF

S4

18

8 -15 of the Used to set the protection


grounding of the transmitting end of E1/ T1
links 15

ON

OFF

S5

1-

16 -23 of the Used to set the protection


ON
E1/ T1
Page39
links 23

OFF

8 Huawei
grounding
of the
end of
Copyright 2006
Technologies
Co.,transmitting
Ltd. All rights reserved.

Board- GDPUC
GDSU

Configured in slot 0 to slot 3, slot 8 to slot 13 of


the GTCS (N+1 redundant backup mode)

RUN
ALM
ACT

Performs the voice and data service processing


function

Encodes and decodes speech services

Performs data service rate adaptation

Performs Tandem Free Operation (TFO)

Performs voice enhancement function

Automatically detects voice faults

PARC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page40

BoardGOMU

As the OM center of the BSC, The GOMUs are installed in slots


2023 in the GMPS and work in active/standby mode. The
GOMU features high computation speed and outstanding data
processing capability .

The GOMU has the following functions:

Provides configuration management, performance


management, fault management, security management,
and loading management for the BSC

Screw
(1)
(3) Wrench
Interfaces(2)toLeaf
thespring
LMT/M2000
on

behalf of the BSC

(4) RUN LED

(5) ALM LED

(6) ACT LED

(7) Reset
button

(8) Shutdown
button

(9) USB port

(10) ETH0
(Ethernet port)

(11) ETH1
(Ethernet port)

(12) ETH2 (Ethernet port)

(13) COM port

(14) VGA port

(15) HD LED

(16) OFFLINE
LED

(17) Hard disk

(18) Screw for fix the hard disk

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page41

BoardGOMU Indicator
LED
RUN

Color
Status
Gre On for 1s and off for 1s
en On for 0.125s and off
for 0.125s
On for 2s and off for 2s
Steady on
Steady off

ALM

Red

On (or flashing)

Steady off
ACT
Gre
Steady on
en
Steady off
OFFLIN Blue
On
E
Off
On for 0.125s and off
for 0.125s
HD
Gre
Flashing
en
Steady off

Description
The board is operating.
The board is loading software.
The board is being tested.
There is power supply but the board is
faulty.
There is no power supply or the board is
faulty.
There is a fault related to the running
board.
There is no alarm.
The board works in active mode.
The board works in standby mode.
The board can be removed.
The board cannot be removed.
The status of the board is switching.
The hard disk is performing read and
write operations.
The hard disk is not performing read and
write operations.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page42

Contents
1.

System Description

2.

Hardware Structure

3.

System Logical Structure

4.

System Signal Flow

5.

Typical Configuration

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page43

Contents
3.

System Logical Structure


3.1 TDM Switching Subsystem
3.2 GE Switching Subsystem
3.3 Service Processing Subsystem
3.4 Service Control Subsystem
3.5 Interface and Signaling Processing Subsystem
3.6 Clock Subsystem

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page44

System Logical Structure


Connection
between
subracks

TDM switching subsystem

Service
processing
subsystem

Service
control
subsystem

Interface
and
signaling
processing
subsystem

E1/STM-1 to BTS
E1/STM-1 to PCU
E1/STM-1 to MSC
Clock
subsystem

Connection
between
subracks

GE switching subsystem

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page45

TDM Switching Subsystem


The Time Division Multiplexing (TDM) switching subsystem provides
circuit

switched domain (CS) switching for the system

Provides TDM bearers for the A, Abis, Ater, and Pb interfaces

Performs TDM switching and providing circuit switched domain (CS)


switching for the system

Provides TDM bearers for the system service processing

Logical Unit

Physical entity

TDM access bearer unit

GEIUB/GOIUB, GEIUP/GOIUP,
GEIUT/GOIUT, GEIUA/GOIUA

TDM switching unit

GTNU

TDM processing bearer


unit

GDPUC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page46

TDM Access Bearer Unit

The TDM access bearer unit provides TDM bearers for the services
on the A, Abis, Ater, and Pb interface. Each board has the same
hardware structure that contains backplane and sub board. By
loading software, the functions of A, Abis, Ater, and Pb interface
can be enabled.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page47

TDM Switching Unit

Intra-Subrack TDM Switching

GTNU (active)

Board

Board

GTNU (standby)

Board

Connection between a board and the active GTNU through


a backplane TDM path
Connection between a board and the standby GTNU
through a backplane TDM path

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page48

TDM Switching Unit

Inter-Subrack TDM switching

Inter-subrack TDM switching is carried out through


mesh interconnections

The BSC6000 supports the following mesh


interconnections between a maximum of four subracks

Mesh interconnections between the GMPS and three GEPSs

Mesh interconnection between four GTCSs

Subrack 1

Subrack 4

Subrack 2

Subrack 3

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page49

Inter-Subrack Interconnections

The right figure


shows the

GMPS
GTNU

0#
GTNU

GEPS
GTNU

3#
GTNU

interconnections
of GTNU
crossover cables
when four
service subracks

GEPS
GTNU

1#
GTNU

GEPS
GTNU

are configured

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page50

2#
GTNU

GTNU Crossover Ethernet


Cable
1

Pin14
A

Pin1
W1

W3

X1

Pin1
A

X3
W2

X2

B
Pin14
B

W4
X4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page51

GE Switching Subsystem

The Gigabit Ethernet (GE) switching subsystem performs


GE switching of signaling and O&M interface

The GSCU performs operation and maintenance of its


subrack and provides GE switching for the other boards in
the same subrack
GSCU (active)

Board

Board

GSCU (standby)

Board

Intra-Subrack Connection
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page52

GE Switching Unit

Inter-subrack GE switching: star interconnection


through crossover networks
Only in Local
GTCS mode:
Crossed LAN
cables between
GSCU

GEPS

GEPS

GMPS

GTCS

GTCS

GTCS

GEPS

GTCS

Note: In Remote GTCS mode, loading path is in Ater interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page53

GE Switching Interconnection
GMPS/GSCU
GE 0

GE TRUNK1

GSCU0

GE 1

GE TRUNK2

GE 2
GE 3

GE 4

GE TRUNK3

GE 0

1 GEPS

Cross LAN cables

GE 1

GE 0
GE 1

GSCU1

GSCU0

2 GEPS

GSCU1

GE 5

GE TRUNK4

GE 6

GE 0
GE 1

3 GEPS

GE 7

GE TRUNK4

GE 8

GE 0
GE 1

GTCS Centre

GE 9

GE TRUNK5

GE 10

GE TRUNK6

GE 11

GBAM

LMT

M2000/NM Center
CPU FE

FE

LanSwitch

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page54

Questions

What is the difference between the local GTCS and the


remote GTCS?

The local GTCS connects with the GMPS through an Ethernet


cable. Only the Ater connection path should be configured

The remote GTCS connects with the GMPS through E1


transmission. Ater connection path as well as the Ater OML
and the Ater signaling link should be configured

When the Ethernet cable between the GTCS and the GMPS or
GEPS is equal to or longer than 10 m, the remote GTCS
should be configured

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page55

Service Processing Subsystem

The hardware entity of the service


processing subsystem is the GDPUC board

Transcoding

Rate adaptation

Every board can process 968


circuits in A interface

Works in resource pool mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page56

Questions

If one GDPUC board is faulty, Will multiple CICs


become unavailable?

No, because GDPUC works in rescues pool mode, other


boards can provide service

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page57

Service Control Subsystem

The hardware entities:

The GXPUM board

The GXPUT board

The GBAM server

The GSCU board in the GTCS subrack

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page58

Service Control Subsystem

The GXPUM board performs the main service processing of the


BSC6000

paging control, system information management, channel


assignment, and BTS common service management

voice call control, PS service control, handover, and power control

The GXPUT board performs the cell broadcast function and LAPD
signaling processes.

The GBAM server performs BTS O&M management

The GSCU board in the GTCS subrack performs the TC resource


pool management

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page59

Interface and Signaling


Processing
Subsystem
The interface and signaling subsystem provides interfaces of BSC,

BTS, and NSS, which performs signaling processing function of


data link layer

Provides A/Abis/Pb/Ater interfaces

Supports cell broadcast message service processing

Supports the MTP2 protocol of SS7 processing

Abis

BTS

GMPS/
GEPS

Ater

MSC

GTCS
BSC

Pb

PCU

Cb

CBC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page60

Interface and Signaling Processing


Subsystem

Signaling Processing

GEIUT/GOIUT in GMPS/GEPS processes the MTP2


signaling of SS7 ,every subrack supports 16 SS7 links
which are 64Kbps and 8 SS7 links which are 2Mbps

GXPUT processes the LAPD signaling in Pb interface,


every subrack supports 64 LAPD links

GXPUT processes the LAPD signaling in A-bis interface.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page61

Interface and Signaling Processing


Subsystem

Traffic Processing

GEIUT/GOIUT supports 3840 speech channels

GEIUP/GOIUP supports 3840 16Kbps PCICs

GEIUA supports 960 speech channels

GOIUA supports 1920 speech channels

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page62

Clock Subsystem

Hardware entity is the GSM General Clock Unit (GGCU)

Clock sources

Building Integrated Timing Supply System (BITS)

2 MHz clock

2 Mbit/s clock

The 2 Mbit/s clock source has higher anti-interference capabilities than the 2
MHz clock source

Line clock

The GTCS extracts line clock from the A interface. The GEIUA in the GTCS
processes the clock and generates 8 kHz

The GTCS sends the 8 kHz clock to the GGCU in the GMPS by the Ater
interface

The GEIUA in the GTCS sends the 8 kHz clock to the GSCU by the backplane in
the GTCS. The GSCU forwards the 8 kHz clock to the other boards in the GTCS

Local free-run clock

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page63

Clock Configuration

Configuration for the clock in the GGCU

Without BITS

GGCU extracts the synchronization reference clock from


the interface board of GMPS

Other distribution cables are not required

GGCU chooses the clock reference of backplane

With BITS

GGCU should be equipped with distribution cables

BITS has high priority

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page64

System Clock Scheme


Active/standby
GGCU
in GMPS

BITS
Backplane
transmission

Distribution cable
transmission

GSCU

GSCU

Backplane
transmission

GSCU

Backplane
transmission

Backplane
transmission

GEPS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Service
board

Service
board

Service
board

Service
board

Service
board

Service
board
GMPS

Line Clock

GEPS

Page65

Clock Synchronization
Interconnection
GEPS

GMPS
GGCU

GGCU

GSCU

CLKIN

CLKIN

Y-shaped
cable

GSCU

GEPS
GSCU

GSCU

CLKIN

CLKIN

W2
8
1

X1

X2

W1
8

W3

X3

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page66

Contents
1.

System Description

2.

Hardware Structure

3.

System Logical Structure

4.

System Signal Flow

5.

Typical Configuration

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page67

Contents
4.

System Signal Flow


4.1 System Signal Flow
4.2 O&M Signal Flow
4.3 Loading Path
4.4 Alarm Channel

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page68

CS Service Signal Flow

Voice service
BTS GEIUB GTNU GEIUT GEIUT
GTNU GDPUC GTNU GEIUA MSC
8K/16K

BTS
Abis

G
E
I
U
B

G
T
N
U

GMPS/GEPS

G
E
I
U
T

16K

Ater

G
E
I
U
T

G
T
N
U
GTCS

G
D
P
U
C

G
E
I
U
A

64K

MSC

A interface

Front board

E1/T1 cable

Rear board

TDM switching on
the backplane

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page69

PS Service Signal Flow

PS service
BTS GEIUB GTNU GEIUP PCU

G
E
I
U
B

BTS
Abis

G
T
N
U

GMPS/GEPS

G
E
I
U
P

PCU

SGSN
Gb

Pb
Front board

E1/T1 cable

Rear board

Backplane TDM
switching

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page70

Service Signal Flow


Abis 16K

64K

16K
16K

64K

64K

64K

GTNU 64K

16K
GTNU

GEIUT

GEIUB
64K

Pb

Ater

64K

GEIUA

GEIUT
GDPUC

64K

64K

BM subrack

GEIUP

TC subrack
A interface

64K

Abis 16K

16K

64K

GTNU

64K

64K

64K
GEIUB

GEIUT

GTNU
64K

BM subrack
Voice service, non-crossover subrack switch
Voice service, crossover subrack switch

GEIUA

GEIUT

GDPUC
(TC)

TC subrack

PS service, non-crossover subrack switch


PS service, crossover subrack switch

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page71

SS7 on the A Interface

SS7 on the A Interface


MSC GEIUA GTNU GEIUT GEIUT
GSCU GXPUM

G
X
P
U
M

G
S
C
U

The signals are processed through the MTP2, and


then sent to the GXPUM in the mode of internal
signaling flow

G
E
I
U
T

GMPS/GEPS
Front board
Rear board

G
E
I
U
T
Ater

G
T
N
U

G
E
I
U
A

GTCS

E1/T1 cable
TDM switching on the backplane
GE switching on the backplane

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

MSC

Page72

LAPD on the Abis Interface

LAPD on the Abis interface


BTS GEIUB GXPUT GSCU GXPUM

G
X
P
U
M

G
S
C
U

G
X
P
U
T

G
E
I
U
B

The signals are processed through the LAPD,


and then sent to the GXPUM in the mode of
internal signaling flow

BTS

Abis
GMPS/GEPS
Front board

E1/T1 cable

Rear board

GE switching on
the backplane

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page73

LAPD on the Pb Interface

LAPD on the Pb interface


PCU GEIUP GXPUT GSCU GXPUM
The signals are processed through the LAPD,
and then sent to the GXPUM in the mode of
internal signaling flow

G
X
P
U
M

G
S
C
U

G
X
P
U
T

G
E
I
U
P

PCU

Pb
GMPS/GEPS
Front board

E1/T1 cable

Rear board

GE switching on
the backplane

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page74

Signaling Signal Flow on the Cb


Interface

Signal signaling flow on the Cb interface

CBC GBAM GSCU GXPUT GSCU


GXPUM
G
X
P
U
M

G
S
C
U

G
X
P
U
T

GMPS/GEPS

The signals are processed through the Cb


interface module, and then sent to service
control subsystem in the mode of internal
signaling flow

G
S
C
U

GBAM

LAN
Switch

Cb

CBC
Front board

Ethernet Cable

Rear board

GE switching on
the backplane

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page75

O&M Flow

M
T

G
B
A
M

Service
board

GMPS

G
E
I
U
T

G
E
I
U
T

Ater

Rear board

GTCS

E1/T1 cable

Service board

Front board

G
S
C
U

G
S
C
U

Network cable
GE switching
on the
backplane

GEPS
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Service board

G
S
C
U

HDLC link

Page76

O&M Flow

O&M path of the GMPS


LMT GBAM GSCU boards of the GMPS

O&M path of the GEPS


LMT GBAM GSCU inter- subrack interconnection cable
GSCU boards of the GEPS

O&M path of the GTCS


LMT GBAM GSCU GEIUT HDLC GEIUT GSCU
boards of the GTCS

O&M path of the BTS


LMT GBAM GSCU GXPUT BTS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page77

Software Loading Path


(Remote
GTCS)
Main GTCS
GMPS
E
I
U
T

G
S
C
U

Service board

G
S
C
U

Service board

G
B
A
M

E
I
U
T

GE on the backplane

G
S
C
U

Inter-subrack Cable

Service board

GEPS

Service board

G
S
C
U

HDLC

GTCS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page78

Software Loading Path (Local


GTCS) GMPS
Main GTCS
G
S
C
U

Service board

Service board

G
B
A
M

G
S
C
U

GE on the backplane
Inter-subrack Cable

G
S
C
U

Service board

GEPS

Service board

G
S
C
U

GTCS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page79

Connection of Alarm Box

Connection scheme

Alarm
management
module
GBAM

Convert
Management
System
LMT

Alarm box
Serial Cable

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page80

Report of Alarm from Local


Subrack
Generate/
Shield
Alarms

Generate
Sounds&Lights

Report
Alarms

GMPS

BTS

Service
board

GSCU

GBAM

LMT
Convert

Alarm box

GEPS
Service
board

GSCU

Send
Alarms
&Record
logs

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Output
Alarms
&Drive
Alarm box

Page81

Report of Alarm from Remote


Subrack
GMPS
Service
board

GSCU

GBAM

LMT
Convert

Alarm box

GEIUT

HDLC
Link

GTCS
Service
board

GSCU

GEIUT

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page82

Contents
1.

System Description

2.

Hardware Structure

3.

System Logical Structure

4.

System Signal Flow

5.

Typical Configuration

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page83

Configuration Principle

GMPS/GEPS configuration principle

GEIUB/GOIUB supports 256 TRXs.

GEIUB/GOIUB provides 32 E1 ports which can work in


1:1, 2:1,3:1,4:1 mode

Both E1 and Optical transmission can be configured in


Pb, Abis interface in the same subrack, but only single
transmission mode can be configured in Ater interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page84

Configuration Principle

GTCS configuration principle

All the GTCSs in the same BSC can only be configured as one single mode
which is local GTCS or remote GTCS

GDPUC can process 968 circuits which uses N+1 redundancy configuration.
All the TC resources are shared in resource pool mode in one subrack

GEIUT/GOIUT supports 3840 speech channels, GEIUA supports 960 speech


channels while GOIUA supports 1920 speech channels, so the proportion
between the number of the Ater interface boards and that of the A
interface boards is 1: 4 or 1:2

Both E1 and Optical transmission can be configured in A interface in the


same subrack, but only single transmission mode can be configured in Ater
interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page85

Typical Configuration

Capacity of
this
configuration:
256TRX full
rate/256TRX
half rate

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page86

Typical Configuration

Capacity of full configuration: When a BSC6000 is


fully configured, it supports 2048TRX full
rate/2048TRX half rate

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page87

Questions

Why should the capacity of the transmission board


be expanded from the middle to the sides?

Because there are lots of cables when the E1/T1


electrical interface is used, the capacity of the
transmission board should be expanded from the
middle to the sides to facilitate the cabling.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page88

Summary

Introduce features and functions of BSC6000

Describe components and functions of racks,


subracks and boards in BSC6000

Describe functions of logical structure and cable


connections in every logical part

List configuration principles and typical


configurations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page89

Thank you
www.huawei.com

Potrebbero piacerti anche