Sei sulla pagina 1di 17

LKPPL STAGE#1

6.6KV/415V SWITCH GEAR


SYSTEMS

M.LAKSHMI
NARAYANA

LKPPL STAGE#1
Lanco Kondapalli Power Plant is a
Combined cycle plant,

Two gas turbines and associated


generators.
Two Heat Recovery Steam Generators
(HRSG), supplying steam to the steam
turbine to the process steam circuit.
One condensing steam turbine
generator set.

GAS TURBINE: GE make,123MW, Frame


9E Dual Fuel Standard Combustion GTs
HRSG: The HRSGs are 3 pressure
level(HP,IP,LP), Natural Circulating Units
manufactured and supplied by Hanjung
of Korea
STEAM TURBINE: Alstom make,130MW
condensing type.
otal plant Output is rated at 368MW

What is auxiliary consumption

Energy consumption by the auxiliaries associated


with the power plant
The auxiliaries associated with the units termed as
unit auxiliaries
The common auxiliaries of the power station termed as
Station auxiliaries

Station auxiliary power fed from


2nos,1x100% Unit transformers , 15KV/6.6KV
simply called as UT-1 & UT-2

2nos,1x100%Station transformers,220KV/6.6KV
simply called as ST-1 & ST-2

6.6KV UNIT SWGR


The Bus formed with UNIT transformer
s is called as UNIT SWGR,
UT-1
UT- 2
Bus-A
Bus-B

15kv/6.6kv
BUS
COUPLER

6.6KV STATION
SWGR

The Bus formed with Station


transformer s is called as Station
SWGR, Transformers are used to supply power for
start-up as well as station auxiliaries

ST-1
ST- 2

220kv/6.6kv

BUS
COUPLER

Bus-A
Bus-B

Transfer
BUSBUS-2
BUS-1

ST#2

ST#
1
UT#1

GT#
1

STG

6.6KV STATION
SWGR
6.6KV UNIT

GT#
2

UT#2

6.6KV system

Major Equipments

1. Circuit breaker
2. Isolators
3. Earth switch
4. Lightning arrestors
5. Current transformers
6. Voltage transformer
7. Relays

Circuit breaker

An electrical power system needs some


switchgear, which is capable of making and
breaking an electric circuit under normal and
abnormal conditions such as short circuits.
The switchgear that performs this function is
known as circuit breaker

Isolators

Isolators are used to making and breaking an electric


circuit under off load conditions.

Earth switch
The earth switch consists of a conductor
bar. When earth switch is to be closed,
these bars connect the contact on line
to earth
Earth switch is connected between the
line conductor and the earth normally
open. When the line is disconnected
the earth switch is closed so as to
discharge the voltage trapped on the
line after the CB and isolators are

Lightening arrestor
The basic purpose of the Lightening Arrestor
to protect the line equipments from the Over
voltage during surges of Lightening
condition.

Current Transformer

Current Transformer is one of Instrument


transformer employed in HV systems for
transformation of high line currents to low
measurable values for measurement &
protection

Potential transformer
Potential transformer is one of Instrument
transformer employed in HV systems for
transformation of high line currents to low
measurable values for measurement &
protection

415V system