Validation
Slide 1 of 27
August 2006
Validation
Part 1. General overview on qualification and validation
Part 2. Qualification of HVAC and water systems
Part 3. Cleaning validation
Part 4. Analytical method validation
Part 5. Computerized system validation
Part 6. Qualification of systems and equipment
Part 7. Non sterile product process validation
Validation
Slide 2 of 27
August 2006
Qualification of systems
and equipment
Part 6
WHO Technical Report Series, No. 937,
2006. Annex 4. Appendix 6.
Validation
Slide 3 of 27
August 2006
Validation
Objectives
To discuss the principles of qualification of systems and
equipment, with specific focus on:
The different stages of qualification
Requalification and
Qualification of in use systems and equipment
Validation
Slide 4 of 27
August 2006
Validation
Principle
Systems and equipment: Appropriately designed, located,
installed, operated and maintained
Critical systems and equipment should be qualified
May include, where appropriate:
Water purification systems, air-handling systems,
autoclaves, coating machines
Continued suitable performance needed
Why? To ensure batch-to-batch consistency
1.1 1.3
Validation
Slide 5 of 27
August 2006
Validation
Scope
Guidelines describe the general aspects of qualification for
systems and equipment
Normally qualification would be applicable to critical systems
and equipment whose performance may have an impact on the
quality of the product
2.1 2.2
Validation
Slide 6 of 27
August 2006
Validation
General
Qualification policy for systems and equipment
To include instruments used in production and quality control
New systems and equipment: All stages of qualification
applicable (DQ, IQ, OQ and PQ)
In some cases: Not all stages of qualification may be required
e.g. electrical supply systems
3.1 3.4
Validation
Slide 7 of 27
August 2006
Validation
General (continued)
Systems: Qualified before equipment
Equipment: Qualified before routine use
Systems and equipment: Periodic requalification, as well as
requalification after change
Certain stages done by the supplier or a third party
Maintain the relevant documentation, e.g.
standard operating procedures (SOPs), specifications and
acceptance criteria, certificates and manuals
3.5 3.9
Validation
Slide 8 of 27
August 2006
Validation
General (continued)
Qualification should be done in accordance with predetermined
and approved qualification protocols
The results of the qualification should be recorded and reflected
in qualification reports
The extent of the qualification should be based on the criticality
of a system or equipment, e.g.
Blenders, autoclaves or computerized systems
3.10 3.11
Validation
Slide 9 of 27
August 2006
Validation
Blender
Discuss the approach of
qualification of a newly
installed blender
Validation
Slide 10 of 27
August 2006
Validation
Stages of qualification
Design qualification
Installation qualification
Operational qualification
Performance qualification
3.11
Validation
Slide 11 of 27
August 2006
Validation
Stages of qualification
Design qualification
Installation qualification
Operational qualification
Performance qualification
Change control
3.11.
Validation
Slide 12 of 27
August 2006
Validation
Design qualification
User requirements should be considered when deciding on the
specific design of a system or equipment
A suitable supplier should be selected for the appropriate
system or equipment (approved vendor)
4.1 4.2
Validation
Slide 13 of 27
August 2006
Validation
Installation qualification
Correct installation as per plan and protocol
Normally advised to prepare requirements for calibration,
maintenance and cleaning at this stage
Identification and verification of all system elements, parts,
services, controls, gauges and other components
Calibrate the measuring, control and indicating devices
against appropriate, traceable national or international
standards
5.1 5.4
Validation
Slide 14 of 27
August 2006
Validation
Installation qualification (2)
Documented records for the installation
installation qualification report
Indicate satisfactory installation
Include details, e.g.
The supplier and manufacturer
System or equipment name, model and serial number
Date of installation
Spare parts, relevant procedures and certificates
5.5
Validation
Slide 15 of 27
August 2006
Validation
The handout shows a typical format for
"An installation qualification protocol / report"
It reflects the minimum information that should be included
This is an example and should be used as such
Specific formats need to be designed for a specific system or
piece of equipment
5.5
Validation
Slide 16 of 27
August 2006
Validation
Operational qualification
Systems and equipment should operate correctly operation
verified as in the qualification protocol
Studies on critical variable to include conditions encompassing
upper and lower operating limits and circumstances (i.e.
worst case conditions)
To include verification of operation of all system elements, parts,
services, controls, gauges and other components
6.1 6.3
Validation
Slide 17 of 27
August 2006
Validation
Operational qualification (2)
Documented records (Operational qualification report)
Finalize and approve SOP (operation)
Training of operators provided training records
Systems and equipment released for routine use after
completion of operational qualification, provided that:
All calibration, cleaning, maintenance, training and related
tests and results were found to be acceptable
6.4 6.7
Validation
Slide 18 of 27
August 2006
Validation
The handout shows a typical format for:
"An operational qualification protocol / report"
It reflects the minimum information that should be included
This is an example and should be used as such
Specific formats need to be designed for a specific system or
piece of equipment
6.7
Validation
Slide 19 of 27
August 2006
Validation
Performance qualification
Systems and equipment should consistently perform in
accordance with design specifications verified in accordance
with a performance qualification protocol
Documented records performance qualification report
Show satisfactory performance over a period of time
Manufacturers to justify the selected period
7.1 7.2
Validation
Slide 20 of 27
August 2006
Validation
The handout shows a typical format for:
"A performance qualification protocol / report"
It reflects the minimum information that should be included
This is an example and should be used as such
Specific formats need to be designed for a specific system or
piece of equipment
7.2
Validation
Slide 21 of 27
August 2006
Validation
Defined schedule
Periodic
Requalification
After change
8.1 8.3
Validation
Slide 22 of 27
August 2006
Validation
Defined schedule
Frequency based on
Factors
Results of calibration
, maintenance
verification
Periodic
Requalification
After change
Extent based on
Risk assessment
Part of
Change control procedure
8.1 8.3
Validation
Slide 23 of 27
August 2006
Validation
Validation
Slide 24 of 27
August 2006
Validation
Qualification of in-use systems and equipment
Data to support and verify the suitable operation and
performance of systems and equipment
Should include operating parameters and limits for critical
variables, calibration, maintenance and preventive maintenance,
standard operating procedures (SOPs) and records
9.1 9.2
Validation
Slide 25 of 27
August 2006
Validation
Validation
Slide 26 of 27
August 2006
Validation
Group session
Validation
Slide 27 of 27
August 2006