Sei sulla pagina 1di 53

Product Details

March 1, 2005
MK, Industrial Safety Systems
Dept.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

ProSafe-RS product name


The name, ProSafe has been Yokogawas brand in the safety
market over many years.
ProSafe is a mix word of Professional and Safety. We offer
the know-how and expertise for plant safety.
RS is a newly added abbreviation of Responsive Solutions.
ProSafe-RS is named to provide the best answer for evolving
safety environment as a total, integrated solutions for process
industries.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

ProSafe-RS product color


The color gives active image of safety and
expresses our willingness to provide the
best safety solutions to customers.

Name of color:

Terracotta Orange

Background of choosing the color:


Orange represents vitality. The color stands out and gives a signal to
people.
Orange has a image of positiveness. It represents that we are willing
to play
active role in calling customers attention for safety.
Customers can easily recognize our product even from afar.
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

ProSafe-RS Projects by Country

Over 300 projects from 50


countries!!
Feb. 2005 - Apr. 2008

Algeria
Angola
Australia
Austria
Belgium
Brazil
Brunei
Bulgaria
Canada
Chili

China
Italy
Congo Japan
Egypt
Kazakstan
France Korea
Germany KSA
Hungary Kuwait
India
Macedonia
Indonesia Malaysia
Iran
Mexico
Iraq
Morocco

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

Page 4

Netherlands
Nigeria
Oman
Pakistan
Philippine
Qatar
Romania
Russia
Singapore
Spain

Sudan
Taiwan
Thailand
Turkey
UAE
UK
Ukraine
USA
Vietnam
Yemen

Confidenti

Key messages to customers


ProSafe-RS is Yokogawas own product backed by
field- proven CENTUM CS3000 technology and long
years of experience in safety system.
ProSafe-RS offers
- Truly integrated system of DCS and SIS
- Safety and high availability in a simple architecture
ProSafe-RS aims not only the integration of SIS to
DCS, but also our consistent business frame from
sales to service & support.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

Field-proven CS3000 technology

Backed by CENTUM CS 3000 technology


Pair & Spare CPU
Redundant CPU module & I/O module
Redundant network
from control highway to data bus in a
module
V net

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

Product BU, Cover

A revolution in
Safety Instrumented System

Expanding the Safety


Spectrum
ProSafe-RS offers something
more beyond conventional ESD
(emergency shutdown) system.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

Product BU, traditional DCS-SIS


ProSafe-RS
- Integrated plant safety
Traditionally, DCS and SIS had
been two separate systems,
because they were built
differently by separate
vendors.
We required separate
- design
- human-machine interface
- manner for maintenance and
- additional work to connect
both systems, etc.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

Product BU, Overall features


The worlds first truly
integrated safety
controller

Functional Safety mark of TUV


Rhineland

ProSafe-RS is certified SIS as


SIL3 by TV in the
integrated configuration.
ProSafe-RS is integrated
directly to V net of CENTUM
CS3000.
ProSafe-RS offers plant
safety, availability, efficiency
without compromise.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

Product BU, one network

Easy System Design


-> No gateway / interface module is needed
for DCS-SIS Data Exchange.
-> No separate layout and communication design
is needed for DCS system & SIS system.
Ethernet

CS 3000 Eng.
Safety system Eng.

CS 3000 HIS

V net

CS 3000 FCS
Safety Controller

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

10

Product BU, Overall features


The worlds first truly
integrated safety controller
Benefits of integration:
- Faster project implementation
by one network,
- Greater operational efficiency
by one window,
- Lower cost of ownership by
one solution.
Advantages in terms of SIS
selection and configuration:
- Simple choice by Single SIL3,
- Availability by redundancy.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

11

Product BU, One process : one network, one


window

One process
: one network, one
window
V net supports safety-related
communications which has
been certified by TV. It
ensures the logical
segregation of DCS and SIS.
This breakthrough is the first
for the process control world.
The integrated DCS and SIS
system can eliminate
separate monitors for two
systems.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

12

Product BU, One process : one network, one


window

One network
requires no gateway or
interface hardware for data
exchange between SIS and
DCS functions.
eliminates the need to
install a dedicated safety
network.
offers much simpler and
quicker route to system
realization without complex
engineering effort for
integration.
reduces maintenance cost.
lowering total manpower on

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

13

Product BU, one network

Data exchange between Safety controllers

-> Safety Communication is available on Vnet.


(Yokogawa original safety protocol, TUV certified)
CS 3000 HIS

V net

Safety
communication

CS 3000 FCS
Safety Controller

No affect to safety comm.


Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

14

Product BU, one network

Data access to Safety Controller


-> No interface module is required.
CS 3000 HIS

V net

Safety Data to FCS

CS 3000 FCS

Safety Controller

Tag access
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

15

Product BU, one network


Time Synchronization by Standard V net
function
GPS as an option (IRIG interface on SCS)
CS 3000 HIS is
V net Timemaster

V net

CPU node
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

CS 3000 FCS
16

Merits of Common Architecture


Standard design of cabinet layout
Standard way of Hardware replacement

FIO

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

17

System configuration with HART module


After R1.02.00

Before R1.02.00
HIS/ENGS

PRM

HIS/ENGS

PRM

SENG

1BUS

Vnet/IP

2BUS

1BUS
2BUS

Vnet/IP

HART

SCS

signal
FFCS-L

Vnet
router

FFCS-L

Vnet

HART

SCS

HART
Equipment

HART

signal

signal

Control
Valves
SENG

HART signal
HART
Multiplexer

HART
Safety Sensor
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

between
MUX and
PRM
via Serial
Communicat
ion
ProSafe-RS R1.02

Safety
Valves

HART signal go though


ProSafe-RS
Without any HART
devices.

18

Optical ESB Bus Repeater


Possible to install I/O node at remote locations via fiber-optic cable.
Maximum 5km in total.

[Example]

Maximum 9 I/O node can be connected.


CPU node
(SSC10/50 )

Fiber-optic cable
Connector:
LC type (IEC60754-20 compliant)
Recommended cable:
Silica-Based Single-Mode Fiber
(JISC6835 SSMA -9.3/125,
IEC60793-2-50B1.1)

V-net
ESB Bus

I/O node
(SNB10D)
ESB Bus

Fiber-optic cable (4 cables)


SNB10D: Max. 9 units
I/O node
(SNB10D)
ESB Bus

Mounting unit dedicated


for optical modules

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

I/O node
(SNB10D)

ProSafe-RS R1.02

19

Product BU, One process : one network, one


window

One window
provides the same
environment to monitor SIS
and DCS in accustomed way.
eases comparison of the
control data and the safety
data, as well as alarms for
quick decision making.
improves back-tracking
analysis of integrated
events.
one solution
reduces the time and cost
required to total process
safety.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

20

Product BU, One window


Tag access from HIS to DCS data and SCS data
Integrated monitoring on HIS
CS 3000 HIS

Integrated Monitoring
- Faceplate
- Trend
- Graphic
- System status
- Alarm
- SOE
V net

ProSafe-RS SCS
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

CS 3000 FCS
21

Enhancements of CS 3000 Integration


New Safety Function for
Manual Operation from HIS
Manual operation of a valve from HIS
Manual Reset PB from HIS
Manual operation and monitoring for
an analog output (4 to 20 mA)
* Safety functions certified by TUV
= Integrated functions with CS3000
is also included TUV Certification.

Support some functions same as CS3000


Alarm suppression on HIS
User defined alarm processing levels
Plant hierarchy

*New version of CS3000 R3.08 is coming.


Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

ProSafe-RS R1.02

22

Product BU, One window


System status

SCS

FCS

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

23

Product BU, One window


Process alarm

ProSafe-RS

All of CS3000 and


ProSafe-RS

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

24

Product BU, One window


System Alarm

ProSafe-RS

All of CS3000 and


ProSafe-RS

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

25

Product BU, One window


1ms resolution
Time & Date
Event name
Comment
Data
Yellow shows
the trip event

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

26

Product BU, Simple solutions are always


best
A single, simple, SIL3
solution
Yokogawas state-of-the-art
design miniaturizes SIS.
Each single module
(processor, input or output) is
SIL3 rated featuring a dual
architecture and extremely
high diagnostic coverage
factor of more than 99%.
This architecture is simple to
understand, design, install
and maintain SIS.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

27

Product BU, single, simple, SIL3


SIL3 will be achieved in single Input-CPUOutput module configuration
- all redundant in a module using proven Pair & Spare CPU
from CS3000 scheme
Single CPU module

Single Input module

Input

Single Output module

CPU

Output

Circuit, MPU

MPU, memory

Circuit, MPU

Circuit, MPU

MPU, memory

Circuit, MPU

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

28

Product BU, Simple solutions are always


best
Plug-in availability
Dual redundant module
configuration for higher
system availability and fault
tolerance with no effect on
SIL3.
Redundant configuration is
selectable part by part, such
as redundant processor
modules with single input
and single output, or a single
input and redundant output.
This flexibility provides a
combination of safety and
economy.
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

29

Product BU, Plug-in availability


High availability will be reached by redundant
module options of CPU module & I/O module.
- Proven redundant technology from CS3000
- Redundant options are selectable part by part!
Redundant CPU module

Redundant Input
module
Input

Redundant Output module


CPU

Output

Circuit, MPU

MPU, memory

Circuit, MPU

Circuit, MPU

MPU, memory

Circuit, MPU

Input

CPU

Output

Circuit, MPU

MPU, memory

Circuit, MPU

Circuit, MPU

MPU, memory

Circuit, MPU

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

30

Product BU, Plug-in availability


Module redundancy is for availability, not for
safety.
System is still SIL3 if all of one side are fail.

Input

CPU

Output

Circuit, MPU

MPU, memory

Circuit, MPU

Circuit, MPU

MPU, memory

Circuit, MPU

Input

CPU

Output

Circuit, MPU

MPU, memory

Circuit, MPU

Circuit, MPU

MPU, memory

Circuit, MPU

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

31

Product BU, Highly scalable architecture


ProSafe-RS employs the
same flexible and scalable
hardware standards as the
CS3000.
ProSafe-RS system can be as
small as one rack with power
supply, processor, and up to
around 100 I/O channels.
System with a (pair of)
powerful processor module
can also be extend to
support around 1000 I/O
points.
ProSafe-RS can be
distributed which will
support up to 64 stations in

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

32

Product BU, Highly scalable architecture


Distribution on Vnet

Large &
distributed

64 stations in a domain, 100 thousand tags


V net

1000 I/Os for a CPU rack and I/O


racks
* 250ms for 1000 IO points

50 I/Os
in a CPU rack
* 50ms for 50 DIO
points

Very Small
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

Total 10 racks
(1000 points)

*Target scan time


33

Product BU, Highly scalable architecture


DCS and SIS share the Vnet components
(repeater/bus converter/gateway)
DCS and SIS are integrated physically,
segregated logically.

Vnet
Domain C

Ethernet
Vnet
Domain A

Safety
ENG

ENG

HIS/ENG

HIS
CGW

SENG

CGW

Repeater

FCS

Optical
Repeater

Safety
Controller

Safety
Controller

FCS

Optical
Repeater

Safety FCS
Controller

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

FCS

FCS
BCV

Vnet
Domain B
SENG

Safety
Safety
Controller Controller

34

Safety
Controller

Product BU, A breakthrough in size


reduction
ProSafe-RS provides a
breakthrough in SIS footprint
and cabinet size comparing
with traditional safety PLCs.
These benefits are for all
users, but particularly for
any application where space
or weight is at a premium
such as
- offshore platform or
- remote equipment stations.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

35

Product BU, A breakthrough in size


reduction

Upper blue area


mentions about
engineering with IEC
61131-3.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

36

Engineering tools
IEC 61131-3 Function Block Diagram & Ladder
Diagram

System & I/O configuration


Test (Simulator on PC / Real target)
Self documentation
Version Control

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

37

Monitoring/Maintenance on Eng PC
Logic status display
System status display & Diagnostic dialog
viewer
SOE viewer
Forcing variables (Input, Output, Logic variables)
Online partial logic modification (TUV to be
certified)

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

38

Product BU, VigilantPlant

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

39

Product BU, Solutions for the safety environment


The growing influence of
functional safety standards
(IEC 61508/61511, ANSI/ISA
S84) are forcing processing
companies to adopt.
Yokogawa's commitment to
IEC 61508 - combined with
the intrinsic simplicity of
ProSafe-RS provides the
ideal platform to support this
trend.
Both ProSafe-RS and the
Yokogawa organization have
been certified to be in
compliance with IEC
61508/61511.
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

40

Product BU, Solutions for the safety environment

These area mentions


about our history,
current products and
support for them.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

41

Product BU, Solutions for the safety environment

This network configuration is available.


Control domain and safety domain
integrated with BCV are also available.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

42

Integration BU, Features of ProSafe-RS


1. Meeting Safety Standards
The safety standards IEC 61508
and 61511 that have world-wide
recognition require precise
safety requirements for process
plants.
Both the ProSafe-RS product
and the YOKOGAWA
organization have been certified
by TV to be in compliance with
IEC 61508 and 61511. ProSafeRS is certified as SIL 3 in a single
module configuration.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

44

Integration BU, Features of ProSafe-RS


2. High Degree of System
Availability
While realizing SIL 3 capability
on a single module, the CPU
and I/O modules of ProSafe-RS
can have dual-redundant
configuration.
This set-up drastically prevents
unexpected plant shutdowns.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

45

Integration BU, Features of ProSafe-RS


3. Highly Scaleable
Architecture
ProSafe-RS employs the same
flexible architecture of
CENTUM CS 3000 R3, allowing
SIS functions to be configured
for any size of application.
ProSafe-RS can also meet
configuration requirements
including centralized and
distributed systems.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

46

Integration BU, Example windows


Control Window
: Control data from FCS and
safety data from SCS can be
monitored in a single window.
Alarm Window
: Alarms for both FCS and SCS
are shown in the single Alarm
Window. Operators can divide
the window to show the alarm
from SCS in the upper section
and all of the alarms in the
lower section.
Tends

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

47

VigilantPlant BU, Cover

Integrated Plant Safety


Management
for Alert Manufactures

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

48

Integrated Plant Safety Management


Safe plants call for more than emergency
shutdown.
Lets look at the big picture.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

49

SEE CLEARLY

BEFORE

A Recurrent
Ailment...

AFTER

...and a Vigilant Remedy

Heavy operator workload


by recurrent alarms

Operators are able to focus


on critical alarms and
predictive alerts

Alarm flooding going


unattended:

AAASuite advanced alarm


administrator:

-Causes oversights, delays, and


incorrect operations

-Suppresses nuisance alarms


automatically

-Leads to unnecessary plant


shutdown

-Add and highlight value-adding


alarms for quick and effective
decision making

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

50

KNOW IN ADVANCE

BEFORE

Protect Reactively,
Analyze
Retrospectively...
Reactive
protection, with
little help to operators and
little synergy with DCS
Conventional ESD system:
- Dedicated human machine
interface
/ network / database
- Analyze events retrospectively,
but realtime information for
operator is cumbersome, slow,
Industrial Safety Systems Dept.
and limited
Copyright Yokogawa Electric Corporation

AFTER

...or Predict, Avoid,


and Minimize
Emergency
Seamless monitoring of
safety data enables
prediction of critical
conditions
ProSafe-RS Safety Controller
- Common HMI and unified event
data for integrated safety
management
- Alerts operators of critical
conditions before they reach
emergency
51

ACT WITH AGILITY

BEFORE

Scrambled
Efforts...

AFTER

...or Orderly Teamwork

Re-start-up is an
intensive non-routine
operation under
extreme pressure

Non-routine but smooth and


reliable operation by
navigator

The ad-hoc approach:

Exapilot advanced operation


navigator:

-A large amount of manual


operations that demand extra
care for timing and attention to
detail
Industrial Safety Systems Dept.
Copyright Yokogawa Electric Corporation

-Interactive and graphical software for


non-routine operational procedure
-Assists interaction intensive
procedure
-Leverages accumulated
know-how of
52

VigilantPlant BU, END

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

53

Thank you for your


attention.

Industrial Safety Systems Dept.


Copyright Yokogawa Electric Corporation

54

Potrebbero piacerti anche