My Home light and motor automation:

BUS system characteristics

System features

Designed for residential application


WDS DIVISION

My Home SCS bus system was designed with

System dimension and feature for homes


Designed to reduce the cabinet dimension
Installation method close to the traditional installation
Aesthetic integrated with WD

Apartment

Villa

BUS system composition


WDS DIVISION

Not one general central unit


No centralized configuration

Power supply

Commands

27V BUS

Actuators

Loads
N
L

SCS bus characteristics


WDS DIVISION

Sender

230V

Information
0 1 0 1 0 1

0 1 0 1 0 1

Receiver

27V d.c. NOT POLARIZED


Power supply and digital data

Load typology driven: most of the typology


WDS DIVISION

Halogen
Discharge

Motors up/down
right/left

Incandescent
Fluorescent

Motors
ON/OFF
LED
6

Wide catalogue range


WDS DIVISION

User interfaces
Actuators
Dimmers
Interfaces
Accessories
7

Traditional configuration
WDS DIVISION

To configure means:
to give a logical
address and a working
mode to each devices

Traditional configuration advantages


WDS DIVISION

The configuration is visible at any time


No special tools/software for configuration
Not specialized competence for any
maintenance

Virtual configuration
WDS DIVISION

The Virtual Configuration is available to configure:


Automation devices
Thermo regulation devices
Energy management

N
L
10

Virtual configuration advantage


WDS DIVISION

Up-Down load system configuration


System configuration scan
Configurators and time saving
Easy re-configuration

You can clone the configuration!


11

Free BUS cabling topology


WDS DIVISION

The choice is based on the installation need, function and


wall limitation
Just one rule: no closed ring!

Star connections

Free connection
12

Physical possibilities: distance


WDS DIVISION

For one power supply only! But you can expand it!

250m MAX
Power supply

500m MAX
Actuator

Control

13

Physical possibilities: absorption


WDS DIVISION

1.200mA available from


the standard power supply
600mA from the
compact power supply

N
L

Table of absorptions on
the technical guide and
YouProject calculates the
total adsorption
For one power supply only! But you can expand it!
15

Why one power supply only?


WDS DIVISION

1 PS

2 PS

2 impedances in parallel cut the digital


16

Logical possibilities
WDS DIVISION

9 Areas

9 PL for every area

9 x 9 = 81 address
(Actuators, command has the same configuration)

For one power supply only!


But you can expand it!

Designed for the


residential sector
17

Lighting management integration


WDS DIVISION

Some MH device are in


common with LM system.
For this reason you can use
the LM configuration rules
and system limits.

18

Configuration
WDS DIVISION

19

Configuration concept
WDS DIVISION

CLICK

Sender
(command)

1. Define the address to identify


sender-receiver link
2. Set the devices function
modality

CLACK

Receiver
(actuator)

N
L
20

Configuration logics: area


WDS DIVISION

Subdivide the plan in


several Areas

3
2

Max 9 areas!
Each area has
maximum
point of light

4
6

21

Configuration logics: point of light


WDS DIVISION

Subdivide the area in several


Point of Light = PL
Max 9 lamp circuits
2
1

3
4

N
L

A
PL

A
PL1
PL2
PL3
PL4

A
PL

22

Configuration logics: motor


WDS DIVISION

Configure the motor actuator


PL1=PL2 to have
interlocked relay

2
3

N
L

A
PL

A
PL1
PL2
PL3
PL4

23

Point-to-point light configuration


WDS DIVISION

Commands to a single device (same A and same PL)


Command
A
PL

Actuator
A
PL

2
3

A=1
PL=1
M=I/O

A=1
PL=2

A=1
PL=3

A=2
PL=1

A=2
PL=2
M=I/O

A=2
PL=3

A=1
PL1=
1

A=1
PL1=
2

A=1
PL1=
3

A=2
PL1=
1

A=2
PL1=
2

A=2
PL1=
3

2
3

24

Point-to-point motor configuration


WDS DIVISION

Commands to a single device (same A and same PL)


Command
Actuator
with in M
Motor as: shutter,
curtain, sunbreaker

A
PL
M

A
PL
M

2
3

A=1
PL=1
M=

A=1
PL=2
M=

A=1
PL=3
M=

A=2
PL=1
M=

A=2
PL=2
M=

A=2
PL=3
M=

A=1
PL1=
1
PL2=
1

A=1
PL1=
2
PL2=
2

A=1
PL1=
3
PL2=
3

A=2
PL1=
1
PL2=
1

A=2
PL1=
2
PL2=
2

A=2
PL1=
3
PL2=
3

2
3

25

Ambient configuration
WDS DIVISION

Command to every actuator with the same


Command
Actuator
configurator A (AMB)
A

AMB

PL

PL1

PL2

A=A
MB
PL=1

Actuator

A=1
PL=1

A=1
PL=2

A=1
PL=3

A=2
PL=1

A=1
PL1=
1

A=1
PL1=
2

A=1
PL1=
3

A=2
PL1=
1

A=2
PL=2
M=

A=2
PL=3
M=

A=2
PL1=
2
PL2=
2

A=2
PL1=
3
PL2=
3
A=A
MB
PL=2
M=

26

Group configuration
WDS DIVISION

Command to every actuator with the same site G (GR)


Command

Actuator

Actuator

GR

PL

PL

GR

A=1
PL=1

A=1
PL=2

A=1
PL=3

A=2
PL=1

A=1
PL1=
1

A=1
PL1=
2

A=1
PL1=
3

A=2
PL1=
1

A=2
PL=2
M=

A=2
PL=3
M=

A=2
PL1=
2
PL2=
2

A=2
PL1=
3
PL2=
3

A=GR
PL=1

A=GR
PL=2

A=A
MB
PL=1

A=A
MB
PL=2
M=

27

General command
WDS DIVISION

Command to every actuator with the same modality


Command
A

One general for lights


One general for motors

GEN

PL

A=1
PL=1

A=1
PL=2

A=1
PL=3

A=2
PL=1

A=2
PL=2
M=

A=2
PL=3
M=
A=GE
N
PL=

A=GR
PL=1

A=GR
PL=2

A=A
MB
PL=1

A=1
PL1=
1

A=1
PL1=
2

A=1
PL1=
3

A=2
PL1=
1

A=2
PL1=
2
PL2=
2

A=2
PL1=
3
PL2=
3
A=A
MB
PL=2
M=

28

Extended command
WDS DIVISION

Extended
command

Point-to-point extended
command between
different logical
extensions

OUT

SCS/SCS

OUT

A=1
PL1=
3
PL2=
3

SCS/SCS

IN

A=1
PL1=
2

IN

A=1
PL1=
1

A=1
PL=1
I=2

A=1
PL1=
3
PL2=
3

Local BUS

MOD=2
I4=2
A=1
PL=2
I=1

A=1
PL1=
2
PL2=
2

A=1
PL1=
1

A=1
PL=3
M=
I=CEN

A=1
PL1=
1

A=1
PL=3
M=
I=2

A=1
PL1=
2

A=1
PL1=
3

MOD=2
I4=1

Private riser

Local BUS

29

Special commands
WDS DIVISION

Light function:
ON timed command
ON command
OFF command
Pushbutton command
ON / OFF command

Configurator:
1-8
ON
OFF
PUL
O/I

Automation function:
UP / DOWN bistable command
UP / DOWN monostable command

M
30

Basic scenarios configuration


WDS DIVISION

Scenario module

Easy scenario with lights and motors

4 scenarios per Unit (command)


16 scenarios per DIN module (memory)
Configure the device (traditional-virtual)
Customizable by the end-user (push & learn)
4 scenarios command

Easy to set-up
Push & Learn
31

Slave configuration
WDS DIVISION

2 actuators with the same address cannot exist!


You have to use
SLAVE

1 relay actuator

32

Memory module
WDS DIVISION

Save the system state in black-out situation


It needs an A/PL address
To save address it can be used in area 0

A=
PL=

0
1 to 9

A
PL

1 module for every system


(phisical extension included)

Memory module

33

System extensions
WDS DIVISION

34

SCS system extended possibilities


WDS DIVISION

One SCS system has Physical & Logical max


possibilities which can be expanded because:
Physical: Distance & Current
Logical: Address

BUS extension

BUS extension

The SCS system could be integrated with RADIO &


LAN because:
If it is not possible to run the BUS

RADIO extension

Web access or smart phone control

LAN extension

35

BUS extension for Current - Distance


WDS DIVISION

One system has 1200mA & 500m


Physical extension to multiply the SCS possibilities
1200mA & 500m

1200mA & 500m

MULTIPLY
1200mA & 500m

1200mA & 500m

M U L T I P L Y

TIMES
1200mA & 500m

T I M E S
36

Physical extensions rules: max 6A & 2.5km


(4 interfaces maximum: 5 buses)

WDS DIVISION

Address 33

34-54

SCS/SCS

OU
T

SCS/SCS

551
IN

IN

11-32

OU
T

331

56-99

Address 55

Max 4 SCS interface: 5 times the max possibilities


The SCS interface takes one available system address to
separate 2 or more system sections
COMMAND

IN OUT

OUT IN

Point to point

PASS

PASS

Area

PASS

PASS

Group

PASS

PASS

General

PASS

PASS

Auxiliary

PASS

PASS

Extended

PASS

PASS

Physical extension MOD=1


I3 & I4 are the link address
All kind of command is interface transparent:
see the table beside

37

Physical extensions: extension


79 total address, 3.6A current and 1.5km bus distance available

WDS DIVISION

MOD=1
I3=3
I4=9

Address
11-38

Address
91-99

MOD=1
I3=8
I4=9

Private riser

Address
41-88

Private riser

Private riser

N
L
38

BUS extension for Address


WDS DIVISION

Local BUSES

One system has 81


address available
Logical extension to
multiply the SCS
possibilities

Private riser

MULTIPLY 10 TIMES
810 address

39

Logical extensions rules: 810 address


(9 interfaces maximum: 10 buses)

WDS DIVISION

Each SCS interface gives 1 digit more


(hungered) to each local bus

Point to point

STOP

STOP

Area

STOP

STOP

Group

PASS

STOP

General

PASS

STOP

Auxiliary

PASS

PASS

Extended

PASS

PASS

LOCAL BUS

SCS/SCS

Address 200

12
IN

LOCAL BUS

SCS/SCS

OU
T

OUT IN

IN

IN OUT

OU
T

22

PRIVATE RISER

Address 300

Some commands are blocked in one direction:


see the table
COMMAND

SCS/SCS

OU
T

LOCAL BUS

IN

Logical extension MOD=2


I4 is the interface address

32

Address 100

Max 9 SCS interface with 10 buses


40

Logical extensions: example


243 total address, 3.6A current and 1,5km bus distance available

WDS DIVISION

Address
211-299

Local BUS

MOD=2
I4=2

N
L

Address
111-199

Local BUS

MOD=2
I4=1
Address
011-099
N
L

Private riser
41

Example: 2 logical and 1 physical extensions 242


total address, 4.8A current and 2km bus distance available
WDS DIVISION

Local BUS

Address
211-299
(- 155)

MOD=2
I4=2

MOD=1
I3=5 I4=5
N
L

Address
111-199

Local BUS

MOD=2
I4=1

Address
011-099
N
L

Private riser
42

Bus-Radio extension
WDS DIVISION

Radio and bus system integrated means:


More installation flexibility
Command wireless
No additional BUS cable

Actuators flush mounting

SCS bus

Radio ZigBee
44

LAN extension
WDS DIVISION

Thanks to the web server it is possible to link BUS & LAN

Local control via smart phones


Local control via MHVISUAL synoptic software
Remote control via web-pages
OPEN integration with 3rd parties available

IP 10.23.45.182

LAN
IP 10.23.45.186
N
L

45

WDS DIVISION

THE END

46

Potrebbero piacerti anche