WIRING
What is Electricity
Meter
A device to
record
Energy
consumptio
n.
Meter
Terminology
No load Test
Starting Current
Current Range
Influence parameters
2.5~5A ( Mech.)
5A~10A ( Mech.)
5A~20A (mech.)
10~40A(Mech.)
10~60A ( Elect.)
Read
Read
Read
Read
Read
15%
26%
53%
Okay
Okay
BSES Electronic
Meters
Specifications
Rating 10~60A
Starting 0.2%
Kwh and MD in KW
TOD, 6 Tariff and 6 time zone
6 Month Billing data
RS232C
Transformer supply
FAQ
Why Mechanical meters read less
Influence Parameters
Age
Wear and Tear
Narrow Range
Mounting
Dust and Oil effect
Mechanical Counters
FAQ
Why electronic meters are preferred
Wide Range
Low starting current
Less effect of Influence
parameters
More accurate
Tamper proof
ROLE OF LED
N-CUT
CAL LED
EL
REV LED
ROLE OF LED
CAL LED
High resolution
out put device for
meter checking
ROLE OF LED
REV
LED
ROLE OF LED
EL
11
ROLE OF LED
N- Cut
The
glowing ABOUT
of the EL LED
KNOW
ELindicates the
following:
Earth is being used as neutral.
Neutral is touching the earth.
Phase / Neutral wire is touching
with
phase / neutral wire of the
neighbour
Neutral wire is interconnected
with the
neighbors13 neutral wire.
KNOW
ABOUT
EL
Wrong wiring, among others
things can result in:
Safety hazards (wires are still
live, even when the main switch is
off).
Cause fire (if by mistake, phase
and
neutral wires get
interchanged)
Wrong Current flow (neighbours
current can flow through your
meter)
14
Good electronic
meters have Current
sensors in both the
Phase path, and
Neutral path
For
For Measurement,
Measurement, it
it
chooses
chooses higher
higher ** of
of
the
the two
two current.
current.
Electro-mechanical
Meter has Current
sensor only on one
wire
All
All Measurement
Measurement
based
based on
on phase
phase wire
wire
current
current even
even when
when
connected
connected to
to
neutral.
neutral.
16
Good electronic
meters have Current
sensors in both the
Phase path, and
Neutral path
This
This is
is an
an advantage
advantage of
of
electronic
electronic meters
meters over
over
electromechanical
electromechanical
meters
meters
Never
Never buy
buy electronic
electronic meters
meters without
without this
this
feature
feature
But
But neutral
neutral looping
looping may
may cause
cause the
the meter
meter
to
to run
run extra
extra
17
KNOW ABOUT EL
If EL is glowing, get your internal wiring
checked for any leakages and other
problems and also carefully look at the
EL LED in the Electronic Meters. EL LED,
in Electronic Meters, however small, is of
great
importance and consumers are advised
not to
ignore its usefulness.
18
HOUSE DISTRIBUTION
BOX
METER
Fuse
MCB / Switch
Phase
Neutral
D. Box
19
NORMAL CONNECTION
I
E
L
N
20
red
=I
mech
yellow
=E
elect
NORMAL CONNECTION
I
E
L
N
JUMPER
21
red
<I
mech
<
yellow
elect
I
E
=I
mech
yellow
=E
elec
NO EFFECT
N
L
red
NO EFFECT
22
EL glow
E
L
mech
=E
elec
NO EFFECT
N
23
EL glow
L
24
EL glow
white = 0
L
25
ELECTRONIC METER
RECORD CORRECTLY
L
No Effect
26
COMMON NEUTRAL
ConsumerMeter Recording
As per
A
Neutral
Current (Extra)
L
N
Consumer
B
L
N
27
As per
Phase
current
(okay)
COMMON NEUTRAL
Consumer
A
L
N
15A
15A
15A
(15+5) A
15A
5A
15A
Consumer
B
15A
15A
10A
28
COMMON NEUTRAL
Consumer
A
15A
15A
L
N
15A
14.5A
15A
0.5A
15A
Consumer
B
15A
(15+0.5) A
29
15A
COMMON NEUTRAL
Consumer
A
15A
L
N
15A
15A
10A
15A
5A
15A
Consumer
B
15A
15A
(15+5) A
30
INTERCONNECTED NEUTRAL
N
31
Wiring Defect
Type Of Defects
Distribution Box
Wiring
32
Distributio
n Box
ELCB
MCB
FUSE
Proper Installation
34
Wiring Defect
Earth (No
Neutral)
N-E
Common N
Common P
Combination
35
Wiring
Defect
Tools
Clamp on
tester
Bulb tester
Line tester
Electrician
Kit.
36
Clamp on tester
37
HOUSE DISTRIBUTION
BOX
METER
Fuse
MCB / Switch
Phase
Neutral
D. Box
GLOW
38
HOUSE DISTRIBUTION
BOX
METER
Fuse
MCB / Switch
Phase
Neutral
D. Box
GLOW
39
Wiring Defect
Step-1.
40
Step-2. Load On
Check I
phase
&I
neutral
If I neutral = 0
Earth is used.
METER
Phase
10A
Neutral
0A
EARTH
EL
NE
41
Common
Neutral
Step-3.
42
Step-4.
At MCB
Phase
Neutral
EARTH
Phase
Neutral
EARTH
44
Step-6.
If V
EN
If common wire
Disconnect one by one Neutral Ckt.
From Bus-bar & see if EL off.
45
Step-8.
i.e.
46
Ip
In
HOUSE DISTRIBUTION
BOX
METER
Fuse
MCB / Switch
Phase
Neutral
D. Box
GLOW
47
Typical Defect
Pts.
Common Load. E.g. Motor
Stair Case Light (i.e. two way
switch.
Common Invertors / Generator.
Houses with separate power &
light meter.
48
49
!!Beware !!
Meter can only be touch by
Discom (BSES) employee.
50