Sei sulla pagina 1di 15

Presentation on Texas Sampling

MD Flow Thru System

Abdul Karim H. Al-Sinan & Partner For Trading Co. (Trading & Contracting), KYTOS ARABIA
P.O. Box 374, Makkah Street, Jubail 31951,KSA
Tel: (966) 13 362 3939; Fax :(966) 13 362 4886

Email:

sales@sinanakh.com

Manual Continuous
Sampling

liquid
into a Bottle or
Container

PROCESS
NEEDLE
PURGE

MD: Sample
Mode

PROCESS
FLOW THRU

VAPOR
VENT

VENT
NEEDLE

PROCESS
NEEDLE

SHROUD
ASSEMBLY
SAMPLE
MODE

DATE:
SCALE:

REV

DATE

REVISED

CLIENT
TITLE

JOB NO.

DRAWING NO.

DESIGNED BY:
DRAWN BY:

ACAD REF

CHECKED BY:

MD: Patented
Purge Mode

MD versus 3-way ball valve

MD has hardened ceramic seat (8x stronger than steel versus


3-way soft seat
MD has (or larger) flow through porting versus for 3-way
MD is proprietary sample valve technology versus 3-way ball
valve technology
MD has TSI bolt pattern for easy addition of secondary ISO
valve or change to stinger tube
MD has a multi-turn handle to allow control of flow into bottle
versus 3-way quarter turn handle
MD has no internal volume allowing for a representative sample
versus 3-way with ball valve cavity.
TSI can supply either the MD or the 3-way versus customer
preference but the MD is a durable robust valve designed for
process sampling

Optional Purge

Flow
Through
Replaceable
Needles

Hardened Seat

Easy Bolt Pattern for


various orientations
6

Vent Needle: Pencil Point

Pencil Point Design: reduces plugging of vent needle

PENCIL POINT VENT NEEDLE


FOR MD, TSI3, MI, MBD

Patented PNP Rotameter


indicates positive flow

Procedure
Tag
Optional
Carbon
Canister

Stainless
Steel Bottle
Shroud

Drawing A1

Ssisisisisisisisis
MD Layout
14"

PROCESS
NEEDLE
PURGE
PRESSURE

NEEDLE
PURGE

12

15

6
5

7"

OPERATING
INSTRUCTIONS

4
3
2
1
0

TO OPEN SAMPLE
VALVE TURN CCW

TEXAS SAMPLING, INC.


(361)575-8087

SAMPLE IN
1/2" TUBE
CONN

SAMPLE OUT
1/2" TUBE
CONN

EXAS
AM PLING
NC.

TM

TO STOP SAMPLE
TURN CW

VENT
1/4" TUBE
CONN

N2
SUPPLY
1/4" TUBE
CONN

FOR FLOW SEE DRAWING TYP-026A


PAT. # - 5,431,067

6-22-95
N.T.S.

KLM

8
9

5-17-99
1-23-01

UPDATE
CHG ROT PLT

5-7-96

UPDATE

2-26-97

PLT MOUNT VLV

4-7-97

UPDATE

6-22-98

ADD CONN.

4-8-99

CHG ROTAMETER

MD - FLOW THRU
SAMPLE SYSTEM
W/ PNP

TYP-026C

10

Additional Features : A1

This drawing features the patented MD flow thru


valve discussed above as well as the pencil point
vent needle
This system is equipped with a bottle enclosure to
further protect the operator
Process block valves are equipped on the inlet and
outlet of the sample system

An

optional cooler is shown for cooling


the process prior to sampling.
11

Drawing E2

12

MD with Stinger and Enclosure


14"

6
5
4

7"

OPERATING
INSTRUCTIONS

3
2
1
0

TEXAS SAMPLING, INC.


(512)575-8087

SAMPLE IN
1/2" TUBE
CONN

SAMPLE OUT
1/2" TUBE
CONN

N2
SUPPLY
1/4" TUBE
CONN

DRAIN
1/2" FNPT

DRAIN
1/2" FNPT

PAT. # - 5,431,067

FOR FLOW SEE DRAWING TYP-025I

4-6-00
N.T.S.

KLM

MD - FLOW THRU
SAMPLE SYSTEM
W/ PNP

TYP-025K

13

Steam Stinger

1.

2.

Drawing E2 is equipped with a


steam stinger so that the
process is kept hot throughout
the sampling process. The
steam stinger will insure that
the sample will not set up in
the line in order to achieve a
representative sample each
time.
This system is also equipped
with a bottle enclosure to
protect the operator from any
exposure to the sample.

14

Thank you to

Potrebbero piacerti anche