Sei sulla pagina 1di 72

University

Getting started
& administration

7302-7330/5523 operator part 1 section A

Alcatel-Lucent University Antwerp

Alcatel-Lucent University
1

Objectives
After completing this section, youll be able to:
Start the AWS
Supervise and monitor the ISAM
Manage the ISAM
Configure the ISAM via the Command Line Interface (CLI)

Table of contents
Starting AWS
ANEL .
.
EML-USM .
EML-USM
EML-USM
EML-USM
EML-USM

.
.
.

.
.
.

Rack view .
Subrack view
Board view
Port view .

Miscellaneous .
.
Management of 7302
Full CLI basic operation
Hands-on .
.
.

.
.
.

.
.
.

.
.
.

.
.
.

.
.
.

p. 4
p.12
p.22

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

P.33
P.36
P.39
P.48

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

P.52
P.56
P.61
p.67

Starting an AWS session

Access to AWS Front Panel


From Solaris Welcome Window:
enter user name
enter password

5523
AWS Icon
Menu

AWS Management System icon


at the bottom right of the AWS Front Panel
access to the functions of 5523 AWS.

WS activity
4

Terminal

AWS
Manageme
nt System
icon

5523 AWS Icon Menu

Allows to select the application


Visible after clicking on the triangle above AWS Mgmt System
icon
information about software elements of 5523 AWS
Launch AWS Application Manager
Launch CAL USM
Launch ANEL

Start/stop AWS core processes (1/3)


Via Process monitoring
Control the UNIX processes running
on the 5523 AWS.
Display the details about the
processes.

Start/Stop AWS core processes:

AWS
APL. MGR

Maintenance

Process Monitoring
(DPC-USM)

select process, group or subsystem


Go to Action Menu -> Start/Stop

Actions menu

or:
Right mouse click -> Start/Stop

Start
Stop

Start/stop AWS core processes (2/3)


DPC-USM
Menu bar
Tree view on all core processes
To see more info on a process:
menu Actions - Show Info

Start/stop AWS core processes (3/3)

RED: At least
one process is
failing

GREEN: Process(es)
up and running

This process has been stopped


BLUE: At least one
process has been stopped

Monitoring AWS core processes


Status Icon or DPC Icon
in the Icon window
Color indication of the status

AWS
APL. MGR

Status Icon: Green or Red


DPC Icon: Green, Blue or Red

Status Window
information about the AWS workstations
displays EML/Presentation workstations
which are installed to become part of the
AWS.
button to launch Process Monitoring

Maintenance

Status

Configuring/verifying AWS license (1/2)

Possibility to configure and show license


Multiple licenses possible, e.g.:

AWSCore
ADSL2+
ADSL2+AnnexM
READSL2
IGMP
PPPoXrelay
PPPoXterm

2 license keys
active license key
for the active master in the 5523 AWS.

passive license key


for the standby master in the 5523
AWS.

10

AWS
APL. MGR

Maintenance
License

Configuring/verifying AWS license (2/2)


Show license rights
Click on a license

AWS
APL. MGR

Configure license

Paste key in field and press OK


Start license process in DPC-USM
Clear:
to erase the license key
Audit:
to show info on (+possibly save)
number of ports
host ID
...

Import:

License

to retrieve the previous license key.

button list logged in users

List logged in
users

11

Maintenance

Clear
Audit
Import

University
ANEL

Navigation and indicators

Alcatel-Lucent University Antwerp

12

Launching ANEL
Main menu
Network Elements

Main menu

AWS
APL. MGR

Administration
AWS Applications
Network Elements

Application

Network
Elements

13

ANEL Overall Structure


Menu
Bar

Window
Title

View
Area

Tree
Are
a
Progres
s
Indicato
r

Filter
Misaligned tag

Tree Area: hierarchical view.


Windows explorer like

View Area: table containing one NE per row.


In hierarchical mode, only NEs within the selected folder are shown
Information given per row: supervision tag, type, ...
14

ANEL view area tags used


Supervision State
Supervised
Declared
Activating
Deactivating

Alarm Synthesis tag


Cleared alarm synthesis tag
Not cleared alarm synthesis tag
Color of tag indicates severity of
highest alarm on NE

Misaligned tag
Reachability tag
Not supervised: no tag
Reachable : no tag
Not reachable

Scoped Command tag


Scoped command ongoing

15

Aligned : no tag
Misaligned

Filter tag
Not filtered : no tag
Filtered

ANEL : Display options


Refresh
Manual refresh of the NE states

Sort

ANEL

The list of the NEs in the View area can be sorted by:

Name,
Location,
Type,
Release,
Supervision state,
Reachability state,
Alarm status,

Sorting can be in ascending or descending order.

Layout
Hierarchical
Folders based on Location Name

Flat view
All NEs in the system are shown
16

Views

Refresh
Sort
Layout

ANEL : Display options


Filter

ANEL

View or list a selection of NEs.


By default no filter is applied
You can create and save a new filter or apply an
existing one.
Filter icon in the lower right corner

17

Views
Filter

Navigation via ANEL


IM load
IM load of EML-IM and LANX-IM processes
(in case of the 7302 ISAM)

ANEL

Show
Allows navigation towards:

EML-USM,
AS-USM,
PM viewer,
Network Events,
TL1 CLI,
Telnet

Views

IM Load
Show
Go to

Go to port by customer
You can select multiple NEs.
Customer id search is not case sensitive
Customer ids that start with the substring that you enter
18

ANEL : Search options


Find (in selected ASAM-CORE)
Find objects matching criteria.
Command only available when NEs are
selected

ANEL

Views menu

Find

NEs

19

NEs by
Template

Subracks

Boards

Appliques

Active
Ppoints

ANEL : Search options


Find (in selected service hub)
Find (sub)NEs matching criteria.
Command only available when a service
hub is selected:
SW files/OSWPs present
Active NT SW file/OSWP
Changes triggered backup
Periodic backup
Clock synchro priority scheme
Auto restore
IP address
System ID

20

ANEL

Views menu

Find

(sub) NEs

ANEL : Service menu


Service

ANEL

Video/IGMP
VLAN

Service menu

Ethernet/IP

NE configuration

Video/IGMP
VLAN
Ethernet/IP

Definition

Create
Modify
Rename
Change Status
Delete

21

Show

Deployment

Deploy
Upgrade
Remove
Show

Utilities

Get free
VLANs

University
EML-USM

Navigation and indicators

Alcatel-Lucent University Antwerp

22

Starting up EML-USM (1/2)


From ANEL

ANEL-USM

Double click on NE
or select one NE View show Equipment
EML-USM opens

EML-USM
Rack view

Four different views in EML-USM

Rack view :
Subrack view:
Board view:
Port view:

shelves in the NE
boards in a subrack
ports on a board
connections on a port

EML-USM
Subrack
view

EML-USM
Board view

EML-USM
Port view

23

Starting up EML-USM (2/2)

Navigation to different views


One level down:
Double click on object in the view area

One level up:


Click on container icon in left upper
corner

ANEL-USM

EML-USM
Rack view

EML-USM
Subrack
view

EML-USM
Board view

EML-USM
Port view

24

EML-USM Overall Structure


Window Title
Menu
Bar
Container
Icon
View Title
Area

Alarm
Synthesis
Panel

Status Icon
Bar

View Area

Alarm overview
area

25

EML USM Menu Bar


Permanent menu items

Context-specific menu items

Menu Bar

Menu Bar - Permanent menu items

26

Views
navigate between views
Configuration configure global NE attributes
Supervision
modify NE associated parameters
Service
configure SVC, ILMI and Video Channels
PM Performance Monitoring
Help Help application

EML-USM Alarm Synthesis Panel


Per-severity alarm subpanel
Number of alarms of that severity
color
Green (square Normal): no alarm
Colored (round) according to the severity: alarms present

Per-domain alarm subpanel


Number of alarms of that domain
color
Green (square - Normal): no alarm
Colored (round) according to the highest severity among the active alarms

Alarms Per-severity alarm subpanel = Alarms Per-domain alarm subpanel

27

EML-USM Status Icon Bar (1/2)


Supervision state:
SUP green (Square) :
SUP brown (Round) :

Operational state:

Supervision active
Supervision not active

Reachability of the NE

ISO Green (Square) : NE is reachable


ISO Red (Round) :

Protection mode:

NT redundancy mode.

OFF yellow (Square) :

Redundancy not active

ON yellow (round) :

Redundancy active

A Green (Round):

Chain A Active

B Green (Round):

Chain B Active

Synchronization mode :

28

NE not reachable

NT database synchronization

NSY yellow (Square):

No synchronization

SYN yellow (Square):

Synchronization

EML-USM Status Icon Bar (2/2)


Backup/restore mode:

ongoing B/R operation on NE

B/R Green (Square) :

No B/R operation ongoing on NE

B Blue (Round) :

Backup ongoing

R Red (Round) :

Restore ongoing

Persistency status:

persistent data loss

PRS green (Square):

No persistent data loss

PRS red (Round) :

Persistent data loss

PPPoE Green (Square) :

enabled

PPPoE Blue (Round) :

disabled

PPPoE Grey (Square) :

not supported

PPPoE server

802.1x authenticator

29

802.1x Green (Square) :

started

802.1x Blue (Round) :

stopped

802.1x Grey (Square) :

not supported

EML-USM - Alarm Display - Alarm synthesis tag


Alarm Synthesis tag = summary of
alarms of the object itself,
and alarms of the contained objects.

All alarms cleared:


At least one alarm present:

Color of the tag is the color of the most severe alarm.

30

EML-USM - Alarm Display - Alarm status tag


Alarm Status tag: summary of alarms of the object itself only.
All alarms on object cleared

At least one alarm present on object

Alarm on object

If the Alarm Status tag is selected, then the alarm overview


area/ panel displays the alarms of the object.

31

Alarm colors

32

RED indicates a critical alarm!

CRI

ORANGE indicates a major alarm!

MAJ

YELLOW indicates a minor alarm!

MIN

BLUE indicates a warning alarm!

WNG

WHITE indicates an indeterminate alarm!

IND

University
EML-USM Rack view

Navigation and indicators

Alcatel-Lucent University Antwerp

33

Rack view presentation / tags (1/2)

Alarm status tag in Icon Container: ASAM related alarms


NT redundancy failure, Label mismatch, Address conflict

Alarm synthesis tag on subrack summarizes alarms of:


subrack itself
contained boards.

Alarm status tag on first subrack of the rack: status of the RACK
External alarms, Power and equipment alarm on Rack level

No display of operational state and administrative state tags for


subracks!

34

Rack view presentation / tags (2/2)


Mismatch
Configured shelf is different from the inserted one

Missing
Configured shelf is not inserted

Top shelf

35

University
EML-USM Subrack view

Navigation and indicators

Alcatel-Lucent University Antwerp

36

Subrack view presentation / tags (1/2)


Alarm status tag in Icon Container: status of the shelf
Power problem, equipment malfunction, configuration issue

Alarm Synthesis tag and Alarm Status tag per board


Alarm Status tag per applique
Administrative state
Locked
Not locked

No tag

Operational state
Disabled
Enabled

Power status
Powered off
Powered on
37

No tag

Subrack view presentation / tags (2/2)


Mismatch

Configured board different from inserted one

Missing

Configured board not inserted

Active chain

Active board (only on NT)

Service hub

(only on NT of 7302 ISAM)

Protection tags
Protection disabled
No tag
Protection enabled (Standby)
Protection enabled (Active)

38

University
EML-USM Board view

Navigation and indicators

Alcatel-Lucent University Antwerp

39

Board view presentation (1/2)


Table structure
One row for each physical port.
One row for each logical group: bonding
Below one bonding group row, one row for each port
part of this group.

Port
Area

Bonding Area

40

Board view presentation (2/2)


Information given per row

ID Label
1

1.
2.
3.
4.
5.
6.
7.
8.

41

Smith
5

View mode button


Row type tag
Type tag
Identification label
Status tag
Customer Identification label
Alarm status tag
Operational state

10

11

12

13

9. Administrative state tag


10. Cross-connection tag
11. Performance monitoring tag
12. IGMP control channel tag
13. Carrier Data Collection

Board view presentation / tags (1/5)


View mode button
"Expand" button indicates that the row is in "reduced mode.
Click to expand reduced row(s)
"Expand all" button: at least one row is in "reduced" mode.
In reduced mode, not all commands are available

Dots tag
in reduced mode means that not all information is displayed.

42

Board view presentation / tags (2/5)


Row type tag
Native port
Bonding group

Type tag

43

User port
Subtending port
Network port

Control port
Out-of-band management

ASAM port

Board view presentation / tags (3/5)


Port/bonding group status tag
Available

Faulty

Reserved

Used

Alarm synthesis / status tag


In "reduced mode only one alarm synthesis tag.
In expanded view max. 8 alarm status tags are used.

44

Port status diagram


Configure
port

nn
.
co

te

Cr

ea

et
e

D
el

u
an
le
C

co
nn

Configured
+
Connection(s)

Configure port
Configured

Unconfigure
s
tu )
a
st LTY
t
U
Se FA

Configure
port

Faulty

45

Unconfigured
(available)

s
tu E)
a
t L
t s ILAB
e
S AVA r ure
o ig
(
f
on
c
Un

Se
(R t s

ES ta
ER tu
VE s
D)

Se

(A t s
VA
IL tat
AB u
Un
o
co r LE) s

nf
ig
ur
e

Reserved

Board view presentation / tags (4/5)


Operational state
Synchronized

Not synchronized

Administrative state
Locked

Not locked

No tag

Cross-connections tag
presence of TP(s) on port/bonding group.

46

or

Board view presentation / tags (5/5)


Presence of performance monitoring points
15 minutes
24 hours
15 minutes and 24 hours

IGMP control channel configured


Carrier Data Collection

47

University
EML-USM Port view

Navigation and indicators

Alcatel-Lucent University Antwerp

48

Port view presentation / tags (1/2)

View area
Table with:
One row with VC Termination Point on the XDSL-Port
One tree for each service/VLAN associated to that logical port

49

Port view presentation / tags (2/2)

50

Administrative state

802.1x enabled

IGMP control channel

Default VLAN

Default VLAN for untagged IPoE frames

LT VLAN association
Create ATM termination
Do not select anything
Connection ATM termination

Associate VLAN:
Select bridge port
ATM
Connection VLAN association termination
create

EML-USM

Port view
Connection
VLAN
association
Create

51

University
Miscellaneous

Alcatel-Lucent University Antwerp

52

Creation of ISAM and Service hub on AWS


NE information
General information on the NE
Type, Release, Name, Location...

EML-workstation and EML-IM process


Security related information
Comments

ANEL

NE

OAM interface of NE
Information necessary to establish
OAM connectivity
Create
Possibility to enable SNTP

OAM interface at EML


Ethernet or ATM

Supervision can be started manually


NE Defaults
53

Show Info
Modify

Delete

NE
defaults

AWS-NE connectivity related commands


Supervision
Start
Stop

ANEL

Reachability Test
IP connectivity
SNMP connectivity
Transaction test

(OAM Counters)

NE

Supervision

Reachabililty
Test

Start
Stop

Counters at OAM interface port of the NE


on IP level
on Ethernet level

Also via EML-USM Supervision OAM Counters


54

(OAM
Counters
not on
ISAM)

Locking
Locking disables the operation of the object!
Lock board
On ISAM: Power on, but all ports are disabled.

Lock port
Restricts all communication over the port, also the physical layer.

Lock NT port
Restricts communication over 1 or more links of an NT link
aggregation group.

Lock ATM termination point


Restricts all communication over a PVC

55

University
Management of 7302 ISAM

Alcatel-Lucent University Antwerp

56

Management strategy (1/4)


Managed as two separate entities.
Alcatel Service Hub
Set-up of VLAN (e.g. new ISP)
Service specific functions performed
on Service Hub

Service Hub and ASAM-CORE


contain a separate SNMP agent

57

Managed as two separate entities.


ASAM/LT shelf (ASAM-CORE)
Rest of the ISAM
Configuration management of users
Set-up of VLAN
Service specific functions performed
on ASAM-CORE

Management strategy (2/4)

Management of 7302 possible by


General CLI
management of ASAM-CORE and Service Hub via General CLI

Via TL1
Management of ASAM-Core and Service Hub

Service Hub CLI


Management of Service Hub

Management via AWS


Management of ASAM-CORE and Service Hub

Configuration possibilities release dependent

58

Management strategy (3/4)

Inband management
use the same interface as the user data path
An Ethernet 100BaseT or1000BaseT network link of the Service Hub is
used for OAM data and for user data
Possible ports: 18 24

Outband management
use a different interface as the user data path
A dedicated Ethernet 100BaseT or 1000Base T network link of the
SHub is exclusively used for OAM data
configured as out-of-band management port
Possible ports: 18 24,
via the 10Base-T Ethernet interface (on NT I/O)
Via RS232
59

Management strategy (4/4)


7302
ISAM
Remote AWS
or CLI

PSTN

A5523
Service
Hub

Remote AWS
or CLI

1 GE

EMAN
NT
1 GE

Router

Remote AWS
or CLI
60

ACU

TL1 & CLIs/RS232

P
S

P
S

.
.
.

NT I/O

Router

LT

LT

University
Full CLI basic operations

Alcatel-Lucent University Antwerp

61

Connecting to the TL1/ Full CLI on the ASAM part


7302
ISAM

Login to the ISAM Full CLI


PSTN

Telnet session
via Serial interface on ACU

Via RS232 port on AACU


4 x FE/GigE
elec or
GigEoptical

LT

NT I/O

NT

SMAS

.
.
.

ACU
LT

Craft Terminal

62

P
S

P
S

DCE DB9 interface


ASCII coding
9600 bps
8 bits
no parity
1 stop bit
No flow control
Parameters are configurable!

CLI:
Login: isadmin
Password: i$@mad-

(to be changed at first time


login)

CLI Basic operations (1/4)


Full CLI can be used to configure and manage ISAM equipment
ASAM Core and Service Hub

The root node is the highest level.


Directly below the root node you find the command nodes
Important command nodes are configure and show.

Show a short explanation on what can entered at this position in the


command..
Enter ?
Possible at each position of a command

Show an extensive explanation on the command.


Enter help

Show configuration
Enter info
Shows only the parameters which dont have the default value.

Enter info detail


shows all nodes and all parameters shown.

63

CLI Basic operations (2/4)


Move cursor left one space
press <left arrow>

Move cursor right one space


press <right arrow>

Recall previous command


press <up arrow> or <ctrl>p
Recall successive commands
press <down arrow> or <ctrl>n
Delete previous input character
press <backspace>

Delete character under the cursor


press <delete>.

Toggle between insert and overwrite mode.


press <insert>.
64

CLI Basic operations (3/4)


Reset command input processing
press <ctrl>c.

Auto completion of the command when only entered partially


Press <Space> or <Tab>

Go one level up
Enter exit

Go to root prompt
exit all

Go to the previous level you were at before you entered the last
command
Enter back

Display the last commands entered at the terminal.


Enter history

Display the structure of configurable nodes and subnodes.


Enter tree
65

CLI Basic operations (4/4)


Telnet session to another server
Enter <telnet IP address>
Telnet session towards Service Hub CLI possible without having IP
address assigned to Service
<telnet shub> command
Exit Telnet session towards shub with <exit>
or connection closed by telnet server (session inactivitytime protection)

Filter
< | match <parameters>

Possible parameters displayed by entering <?>

66

University
7302/5523 Hands-on

Getting started with the CDE & Alcatel 5523 AWS

Alcatel-Lucent University Antwerp

67

Hands-on

Hidden Slide, see Notes Page


Exercises
Getting started with the CDE & Alcatel 5523 AWS
ANEL features of AWS
License Key of 5523 AWS

68

Hands-on

Hidden Slide, see Notes Page


Exercises
Getting started with the CDE & Alcatel 5523 AWS
ANEL features of AWS
License Key of 5523 AWS

69

Hands-on

Hidden Slide, see Notes Page


Exercises
Getting started with the CDE & Alcatel 5523 AWS
ANEL features of AWS
License Key of 5523 AWS

70

Hands-on

Hidden Slide, see Notes Page


Exercises
Getting started with the CDE & Alcatel 5523 AWS
ANEL features of AWS
License Key of 5523 AWS

71

www.alcatel-lucent.com

72

Potrebbero piacerti anche