Before Installation TMB, Please check basic points.
1)
2)
Check data cable connection and all SMA/N type connector connection
3)
3)
4)
5)
6)
7)
TMB-9100 is very high powered RF so that Be careful when you set TMB parameters.
8)
Remote GUI: Click MAIN" button (Refresh) after getting SMS from TMB-9100
9)
www.gsinstrument.com
LOGO
TMB Operation
1. Auto Level Control Function (Mandatory)
- TMB has automatic function to protect its circuit while output power is higher than 52dBM in traffic increasing time
- The reduction of TX Gain will be reduced and the step is 0.5dB
2. ALC Mode (Optional setting)
- In high traffic sector, please set ALC Mode On and ALC Level.
- Max ALC level range is from 40 to 51dB.
- It will automatically optimize the TX Gain with 0.5dB step.
3. Auto Recovery Algorithm
- TMB will alive automatically if TMB has Overpower alarm, DC Fail, VSWR
4. TMB Power Detection time
- Detection gap: 100ms
- It will provide real time measurement but the accuracy will be less than Spectrum Analyzer.
- BTS output power will be changed within 1ms according to traffic increase
- The detected output power in GUI cannot be same with real BTS output power
5. SMS delay or missing
- While MCU is working with other job, it cannot update or report alarms and control command.
- Try again to set or check TMB unit.
- After setting TMB, it takes time to report new information. Try again to get new information.
www.gsinstrument.com
LOGO
Alarm Condition
Parameter
Remarks
Over Power
Over Temperature
VSWR
DC
MCPA Fail
MCPA Enable
O
O
X
X
RX LNA
DIV LNA
Door
Interior Temperature
FAN
By Pass Mode
FAN Fail
MCPA Enable Alarm, Over Power Alarm, DC Fail Alarm, RX LNA Fail Alarm,
Over Temperature Alarm, VSWR Alarm, Bypass module fail
www.gsinstrument.com
LOGO
Work Processes
Parameter
Each Module
& TMB Change
Alarm
Pre-steps
Trouble shooting
Over Power
Over Temperature
VSWR
MCPA Fail
MCPA Enable
DC
RX LNA
RX LNA
DIV LNA
DIV LNA
Door
Door Sensor
Interior Temperature
FAN
FAN
FAN
By Pass Mode
Bypass Module
Remark
MCPA Module
www.gsinstrument.com
LOGO
Pre-Steps
www.gsinstrument.com
LOGO
Trouble Shooting
Alarm Lists
MCPA Alarm
Alarm Cases
Troubleshooting
- Reset the TMB
- Warming up: Min 30minutes
- Set 0dB TX Gain
- Increase TX Gain step by step (0.5dB)
VSWR
RX LNA
DIV. LNA
MCPA
Enable
Over Power
www.gsinstrument.com
LOGO
Trouble Shooting
Alarm Lists
Alarm Cases
Troubleshooting
Over
Temperature
DC Fail Alarm
Door Open
Door Sensor is defected
FAN Fail
- Check FAN
FAN Alarm
Internal
Temperature
www.gsinstrument.com
LOGO
Trouble Shooting
Remote GUI & Modem Box
please check your PC and modem connection, and SIM card 2) Turn on and off Modem box 3) Insert SIM card again.
1. Local GUI and Remote GUI are optimized for O/S of Window 7 and XP.
Other version of O/S cannot be suitable for GUIs and Remote Access.
2. Modem Box cannot be compatible for USB port of your PC.
Please use other USB Port or your PC if there are several Pop-up menu for disconnection.
3. If the communication between GUI and Modem box are disconnected, Pop up-menu can be generated.
Please click ok and check Modem
4. If you order several message in case that you cannot
receive replies from TMB or other purpose, this modem
can handle every requests from you and TMB so that this
message will be come.
Please restart Remote GUI for solving the matter or
turn off /on the modem box.
5. In few case, SIM card error will be happened.
You connect and check everything is OK but if the
communication between GUI and TMB is not proper,
Please check SIM Card connection or SIM Card Error.
6. Please erase SMS by using SMS clean button after finishing a site requests and controls