Sei sulla pagina 1di 17

7745 Alarm TRX

CHANNEL FAILURE RATE ABOVE DEFINED


THRESHOLD

Nokia Siemens Networks. All rights reserved.

7745
CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
Meaning

The rate of calls terminating in failure on a channel is above the threshold


value set by the operator. The alarm is used to supervise the functioning
of traffic and signaling channels, and to detect the possible faulty
channels.
Category
Quality of Services Alarm, Severity Medium
KeyWord
Whenever a channel is released with a release cause other than a normal one,
the counter of channel failures for the released channel is incremented.

Default Threshold
TCHFR = TCH failure rate (20 % or 30%)
SCHFR = SDCCH failure rate (80 %)
PRDCFR = length of supervision period (60 min)
CS = channel seizure threshold value (10)
2

Nokia Siemens Networks. All rights reserved.

7745
CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD

Channel Release procedure

Whenever a channel is released with a release cause other than a normal one,
the counter of channel failures for the released channel is incremented.
After a certain observation time and a certain threshold it will reported in the
7745 alarm. It give an indication that theres a failure that need to be addressed,
but overall KPI need to be used as a first priority.
3

Nokia Siemens Networks. All rights reserved.

7745
CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
7745 alarm occurance in Telkomsel Netowrk
Around 90% is affected in TCH, around 10% is affected in SDCCH
Abnormal relase cause defined below :
TCH Failure
0A Channel state conflict between RRMPRB and ABIPRB
0B Channel type conflict between RRMPRB and ABIPRB
0D TCH radio failure
0E Source TCH radio failure in HO
0F Target TCH radio failure in HO
1D TCH transcoder failure
1E Source TCH transcoder failure in HO
1F Target TCH transcoder failure in HO
2E TCH failure due to a LAPD failure
2F TCH failure due to a BTS failure
30 TCH failure due to user actions
31 TCH failure due to a BCSU reset
32 TCH failure due to radio network reconfiguration actions
51 TCH activation failure during call set-up
53 Target TCH activation failure in HO
54 TCH failure due to an Abis interface failure in call set-up
55 Source TCH failure due to an Abis interface failure in HO
56 Target TCH failure due to an Abis interface failure in HO
57 TCH failure due to an A interface failure in call set-up
58 Source TCH failure due to an A interface failure in HO
59 Target TCH failure due to an A interface failure in HO
FF Actually no release cause, but causes all channels with
an abnormal release cause to be listed

Nokia Siemens Networks. All rights reserved.

SDCCH Failure
03 SDCCH radio failure
04 Source SDCCH radio failure in HO
05 Target SDCCH radio failure in HO
0A Channel state conflict between RRMPRB and ABIPRB
0B Channel type conflict between RRMPRB and ABIPRB
23 SDCCH failure due to a LAPD failure
24 SDCCH failure due to a BTS failure
25 SDCCH failure due to user actions
26 SDCCH failure due to a BCSU reset
27 SDCCH failure due to radio network reconfiguration actions
48 SDCCH activation failure during call set-up
4A Target SDCCH activation failure in HO
4B SDCCH failure due to an Abis interface failure in call set-up
4C Source SDCCH failure due to an Abis interface failure in HO
4D Target SDCCH failure due to an Abis interface failure in HO
4E SDCCH failure due to an A interface failure in call set-up
4F Source SDCCH failure due to an A interface failure in HO
50 Target SDCCH failure due to an A interface failure in HO

7745
Alarm Information
<HIST> AKSES_UI BCF-0065 BTS-0156 QUAL
2009-01-13 13:51:49.59
** ALARM TRX -006
JNCSILIWANGIMD2
DISABLED
(60756) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 01 01 01 01 01 00 00 04 00 48d

<HIST> AKSES_UI BCF-0065 BTS-0156 QUAL


2009-01-13 13:51:49.59
.. CANCEL TRX -007
JNCSILIWANGIMD2
ENABLED
(60755) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 00 00 00 00 0d

Supplementary information fields


1 indicates if the alarm is on the TCH or on the SDCCH channel 01: TCH 02: SDCCH
2..9 indicates if the channel failure rate is above the defined threshold in time slot 0 00: belove threshold (no alarm) 01: above
threshold (alarm)
10 time slot with the highest failure rate
11 subchannel identification TCH: 00: TCH/H -subchannel 0 01: TCH/H -subchannel 1 02: TCH/F -subchannel subchannel
identification SDCCH: 00 - 07: SDCCH -subchannel 0 7
12 proportion of TCH or SDCCH subchannel releases due to failure in all channel releases on a given channel during the
measurement period

Nokia Siemens Networks. All rights reserved.

Tools or verification that have been performed so


far by NSN before/during site visit
Basic SW for Monitoring NE
MML, BTS Manager

KPI Browser

Cell Doctor (report 211 Network Doctor) OSS


Cell KPI (report 204 Network Doctor) OSS

Basic verification of site condition for new sites

VSWR test verification (VSWR, RL, DTF verification)


Verification of Main and Diversity receive level
TRX Test function from BTS manager

Nokia Siemens Networks. All rights reserved.

Step By Step Summary


Flowchart for investigation methodology

Nokia Siemens Networks. All rights reserved.

BTS installation standart

TX1,2 dan RX main

TX 3 , 4 dan RX div

Nokia Siemens Networks. All rights reserved.

If we have 7745, 7604 alarms in our network, what is


really happening?
If: VSWR have been checked,
Then: we can find out from hardware by checking its transmit path from
TRx unit, Tx port, SMA-cables from Tx port to WCxA, WCxA itself, and
so on, until its feeder connection and antenna.
Thus:
7604 alarm is usually related to degraded receive quality of one
sector or one TRx.
From hardware point of view:
check its receive path from TRx unit, Rx main and RxDiv port,
SMA cables from Rx port to M2xA, M2xA itself, and so on, until its
feeder connection and antenna.
Futher investigation:
if we have feeder antenna cable broken, it may raise 7745, and
7604 as feeder is used as transmit and receive paths. Use ND report to
strengthen your analysis. Usually ND report 195, 196,153 and 232.
9

Nokia Siemens Networks. All rights reserved.

Sample ND 196

Performance Analysis:
IF: band q5 value is under 90%
THEN: we suspect that the TRX have bad quality uplink
or
Downlink ( in this case downlink issue)
Solution:
Tightening the cable connection and fixed feeder quality

10

Nokia Siemens Networks. All rights reserved.

Sample ND 195

This report

shows for each TRX:

Ave MS pwr attn


/lb_11 Average MS power
attenuation (dB)
Ave BS pwr attn
/lb_12 Average BS power
attenuation (dB)
Ave UL str
/lb_9 Average UL signal
strength
Ave DL str
/lb_10 Average DL signal
strength
. The signal (UL, DL) strength is given as value
0..63 (GSM 5.08)
.
0 =less than -110dBm, 1= -110 to -109 dBm,
3= -109 to -108dBm
. ... 62 = -49 to -48,
63=greater than -48
11

Nokia Siemens Networks. All rights reserved.

Base on BTS installation standard that :


1.

For Down link TX 1 and TX 2 have big


differences , also for TX5 and TX6 for
sec 2

2.

For Uplink RX main having 3db diff in


sec 1, for sec 2 have 9 db diff

Sample ND 232 ( Time advance)


this site having overshoot issue

12

Nokia Siemens Networks. All rights reserved.

Sample ND 232
this site having overshoot issue

13

Nokia Siemens Networks. All rights reserved.

AUDIT ANTENNA and Neighbour

14

Nokia Siemens Networks. All rights reserved.

Sample ND 153 ( handover)

MancagarMD3 to CiropohMG2 and cisarunimg having 100% fail


mancagarMD3 to mancagar MG3 having 85 of 2144 sample call Fail
this report showing incoming and Outgoing handover
15

Nokia Siemens Networks. All rights reserved.

Exception for 7745

1.
2.
3.

7745 will keep occur for this condition :


No have neighbors cell ( island or remote standalone)
Landscape contour ( hill and valley)
Obstacle

This exception need to be justify as long as the KPI value


achieve

16

Nokia Siemens Networks. All rights reserved.

Summary
& Recommendation
Summary of findings from 7745 alarm in TELKOMSEL network (March May 09) :
Many things that can lead to alarm 7745, it can be categorised as below :
Transmission issue, Power Related issue
Environment Related, Air Conditioning, Temperature
BTS HW problem related, Cooling Fan, Modul faulty
BTS Antena Line
Coverage Issue
Configuration Mismatch between BSC and BTS/MMI
Some existing problem in the old SW
Other maintenance activity in the BSC level
RECOMMENDATION
The affected factor need to be investigated carefully by understanding the root cause.
This alarm give information that theres an abnormal channel release that we need to
be aware.
KPI verification need to be addressed first rather than looking at the amount of this
alarm appear.
17

Nokia Siemens Networks. All rights reserved.

Potrebbero piacerti anche