1.1 Drop Call - T310


Value Range: MS0_T310(0ms), MS50_T310(50ms),
MS100_T310(100ms), MS200_T310(200ms),
MS500_T310(500ms), MS1000_T310(1000ms),
MS2000_T310(2000ms)

Default Value = MS1000_T310 (1000ms)


Eran 3.0
Default Value = MS200_T310 (200ms)
Eran 2.1
Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1
Eran 2.1

MS1000_T310
MS200_T310
MS1000_T310

822
6
510

Meaning: Indicates the length of timer 310. For details, see 3GPP TS 36.331.

1.2 Drop Call - T311


Value Range: MS1000_T311(1000ms), MS3000_T311(3000ms),
MS5000_T311(5000ms), MS10000_T311(10000ms),
MS15000_T311(15000ms), MS20000_T311(20000ms),
MS30000_T311(30000ms)

Default Value = MS10000_T311 (10000ms)


Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

MS10000_T311
MS10000_T311

822
516

Meaning: Indicates the length of timer 311. For details, see 3GPP TS 36.331.

1.3 Drop Call N311


Value Range: n1(1), n2(2), n3(3), n4(4), n5(5), n6(6), n8(8),
n10(10)

Default Value = n1
Default Value = n5

Eran 3.0
Eran 2.1

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1
Eran 2.1

n1
n1
n5

822
510
6

Meaning: Indicates the length of timer 311. For details, see 3GPP TS 36.331.

1.4 Drop Call N310


Value Range: n1(1), n2(2), n3(3), n4(4), n6(6), n8(8), n10(10),
n20(20)

Default Value = n10


Default Value = n6

Eran 3.0
Eran 2.1

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1
Eran 2.1

n10
n6
n10

822
6
510

Meaning: Indicates the maximum number of successive "out of sync" indications received from L1.

1.5 Drop Call S1MessageWaitingTimer


Value Range: 10~200
Default Value = 20

Version

Parameter Value

No Of eNodeBs

Eran 3.0

20
Eran 2.1 do not have this
para

274

Eran 2.1

Meaning: Indicates the timer governing the period the eNodeB will wait for a response message from
the MME.

1.6 Drop Call X2MessageWaitingTimer


Value Range: 10~200
Default Value = 20

Version

Parameter Value

No Of eNodeBs

Eran 3.0

20
Eran 2.1 do not have this
para

274

Eran 2.1

Meaning: Indicates the timer governing the period the eNodeB will wait for a response message from
the MME.

1.7 Drop Call UeInactiveTimer


Value Range: 0~3600
Default Value = 20
Eran 3.0
Default Value = 1800
Eran 2.1

Version

Parameter Value

No Of eNodeBs

Eran 3.0
Eran 2.1
Eran 2.1

20
1800
10

274
1
171

Meaning: Indicates the length of the UE inactivity timer. The eNodeB monitors whether UEs are
receiving or sending data. When a UE has neither received nor sent data for a duration exceeding this period
of time, the eNodeB releases the radio resources for the UE. If this parameter is set to 0, the UE inactivity
timer is not used.

2.Access

1.
2.
3.
4.
5.

T300
CellRadius
CellBarred
InitPdcchSymNum
UuMsgSimulSendSwitch

2.1 Access T300


Value Range: MS100_T300(100ms), MS200_T300(200ms),
MS300_T300(300ms), MS400_T300(400ms),
MS600_T300(600ms), MS1000_T300(1000ms),
MS1500_T300(1500ms), MS2000_T300(2000ms)

Default Value = MS200_T300


Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

MS200_T300
MS200_T300

822
516

Meaning: Indicates the timer value of Timer 300. For details, see 3GPP TS 36.331.

2.2 Access CellBarred


Value Range: CELL_BARRED(Barred), CELL_NOT_BARRED(Not
Barred)

Default Value = CELL_NOT_BARRED

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

CELL_NOT_BARRED
CELL_NOT_BARRED

822
516

Meaning: Indicates the radius of the cell.

2.3 Access CellRadius


Value Range: 1~100000
Default Value = 10000 (m)

Version
Eran
Eran
Eran
Eran

Parameter Value

No Of Cells

4000
10000
4000
10000

567
255
414
102

3.0
3.0
2.1
2.1

We opt this parameter for good access, some site changed to


10000 meters.
Meaning: Indicates the radius of the cell.

2.4 Access InitPdcchSymNum


Value Range: 1~4
Default Value = 3

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 3.0
Eran 2.1

1
3
3

798
24
516

Meaning: Indicates the number of OFDM symbols initially occupied by the PDCCH.

2.5 Access UuMsgSimulSendSwitch


Value Range: OFF(Off), ON(On)
Default Value = ON

Version

Parameter Value

No Of eNodeBs

Eran 3.0
Eran 3.0

OFF
ON
Eran 2.1 do not have this
para

120
154

Eran 2.1

Meaning: Indicates whether an eNodeB uses serial or parallel message transmission mode during
security mode activation and RRC reconfiguration procedures. If this parameter is set to ON, the eNodeB
uses parallel transmission mode. If this parameter is set to OFF, the eNodeB uses serial transmission mode.

3.Paging

1.
2.
3.
4.

ModifyPeriodCoeff
PchPwr
DefaultPagingCycle
Nb

3.1 Paging ModifyPeriodCoeff


Value Range: MOD_PERIOD_COEFF_N2(2),
MOD_PERIOD_COEFF_N4(4), MOD_PERIOD_COEFF_N8(8),
MOD_PERIOD_COEFF_N16(16)

Default Value = MOD_PERIOD_COEFF_N2


Default Value = MOD_PERIOD_COEFF_N4

Eran 3.0
Eran 2.1

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 3.0
Eran 2.1

MOD_PERIOD_COEFF_N2
MOD_PERIOD_COEFF_N4
MOD_PERIOD_COEFF_N4

816
6
516

Meaning: Indicates the modification period coefficient for the BCCH. BCCH modification period =
Modification period coefficient x Default paging cycle, where the BCCH modification period and default paging
cycle are measured in unit of radio frames, and the modification period coefficient is specified by this
parameter.

3.2 Paging PchPwr


Value Range: -3175~3175
Default Value = 0

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

0
0

822
516

Meaning: Indicates the offset of the transmit power for the paging information on the PDSCH channel
relative to the reference signal power.

3.3 Paging DefaultPagingCycle


Value Range: rf32(32 radio frames), rf64(64 radio frames),
rf128(128 radio frames), rf256(256 radio frames)

Default Value = rf128

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

rf128
rf128

822
516

Meaning: Indicates the default paging period for the cell. It is also called the discontinuous reception
(DRX) period. If the EPC specifies a DRX period for a UE, the UE compares this period with the value of this
parameter and uses the smaller one as its DRX period. If the EPC does not specify a DRX period, the UE
uses the value of this parameter, which is delivered in the system information, as its DRX period. For details,
see 3GPP TS 36.304.

3.4 Paging Nb
Value Range: FOURT, TWOT, ONET, HALFT, QUARTERT,
ONE_EIGHTT, ONE_SIXTEENTHT, ONE_THIRTY_SECONDT

Default Value = ONET

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

ONET
ONET

822
516

Meaning: Indicates the number of paging occasions (subframes or times of paging) contained in a
paging cycle.
For details, see 3GPP TS 36.304.

4.Intra-RAT

1. IntraFreqHoA3Hyst
2. IntraFreqHoA3Offset
3. IntraFreqHoA3TimeToTrig

4.1 Intra-RAT IntraFreqHoA3Hyst


Value Range: 0~30
Default Value = 2 (0.5dB)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

4
4

822
516

HQ evaluate this parameter for STC NW, give the suggestion


to change to 4.
Meaning: Indicates the hysteresis for event A3 associated with intra-frequency handover. This parameter
prevents frequent triggering of event evaluation due to radio signal fluctuations. This reduces the probability of
ping-pong handovers or handover decision errors. A larger value of this parameter results in a lower
probability. The hysteresis for event A3 associated with inter-frequency handover is the same as the value of
this parameter. For details, see 3GPP TS 36.331.

4.2 Intra-RAT IntraFreqHoA3Offset


Value Range: 0~30
Default Value = 2 (0.5dB)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

4
4

822
516

HQ evaluate this parameter for STC NW, give the suggestion


to change to 4.
Meaning: Indicates the offset for event A3. If the parameter is set to a large value, an intra-frequency
handover is performed only when the signal quality of the neighboring cell is significantly better than that of
the serving cell and other triggering conditions are met. For details, see 3GPP TS 36.331.

4.3 Intra-RAT IntraFreqHoA3TimeToTrig


Value Range: 0ms, 40ms, 64ms, 80ms, 100ms, 128ms,
160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms,
2560ms, 5120ms

Default Value = 320ms


Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

320ms
320ms

822
516

Meaning: Indicates the offset for event A3. If the parameter is set to a large value, an intra-frequency
handover is performed only when the signal quality of the neighboring cell is significantly better than that of
the serving cell and other triggering conditions are met. For details, see 3GPP TS 36.331.

5.Inter-RAT

1. SNonIntraSearch
2. ThrshServLow
3. InterRatHoA1A2Hyst
4. InterRatHoA1A2TimeToTrig
5. InterRatHoA1ThdRsrp
6. InterRatHoA1ThdRsrq
7. InterRatHoA2ThdRsrp
8. InterRatHoA2ThdRsrq
9. BlindHoA2ThdOffset
10. InterRatHoUtranB1ThdRscp
11. CsfbHoUtranB1ThdRscp
12. InterRatHoA1A2TrigQuan

5.1 Inter-RAT SNonIntraSearch


Value Range: 0~31
Default Value = 7 (2dB)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1
Eran 2.1

7
7
10

822
513
3

HQ recommended to set as 7.

Meaning: Indicates the measurement triggering threshold for reselection to inter-frequency or inter-RAT
cells. The step is 2 dB.

5.2 Inter-RAT ThrshServLow


Value Range: 0~31
Default Value = 7 (2dB)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1
Eran 2.1

7
7
10

822
513
3

HQ recommended to set as 7.

Meaning: Indicates the threshold used in the evaluation of reselection to a cell on a lower priority EUTRAN frequency or on an inter-RAT frequency. Cell reselection to a cell on a lower priority E-UTRAN
frequency or on an inter-RAT frequency is performed if no cell on the serving frequency or on a higher priority
E-UTRAN frequency fulfills criteria 1 for inter-frequency and inter-RAT reselections. For details, see 3GPP TS
36.304.

5.3 Inter-RAT InterRatHoA1A2Hyst


Value Range: 0~30
Default Value = 2 (0.5dB)
Default Value = 4 (0.5dB)

Version
Eran
Eran
Eran
Eran

3.0
3.0
2.1
2.1

Eran 3.0
Eran 2.1

Parameter Value

No Of Cells

2
4
2
4

798
24
3
513

Meaning: Indicates the hysteresis for inter-RAT measurement events A1 and A2. This parameter is used
to prevent frequent triggering of event evaluation caused by radio signal fluctuation. In this way, the probability
of ping-pong handovers or handover decision errors is reduced. A larger value of this parameter results in a
lower probability.

5.4 Inter-RAT InterRatHoA1A2TimeToTrig


Value Range: 0ms, 40ms, 64ms, 80ms, 100ms, 128ms,
160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms,
2560ms, 5120ms

Default Value = 640ms


Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

640ms
640ms

822
516

Meaning: Indicates the time-to-trigger for inter-RAT measurement event A1 or A2.


When detecting that the signal quality in the serving cell meets the entering condition, the UE does not send a
measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal quality
continuously meets the entering condition during the time-to-trigger.

5.5 Inter-RAT InterRatHoA1ThdRsrp


Value Range: -141~-43
Default Value = -111 (dBm)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1
Eran 2.1

-111
-111
-105

822
513
3

HQ recommended to set as -111.

Meaning: Indicates the RSRP threshold for inter-RAT measurement event A1.
When the measured RSRP value of the serving cell exceeds this threshold, an event A1 report will be sent.
The value -141 does not take effect and is reserved for backward compatibility. If this parameter is set to -141,
the value -140 is used as the threshold in implementation.

5.6 Inter-RAT InterRatHoA1ThdRsrq


Value Range: -40~-6
Default Value = -20 (0.5dB)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

-20
-20

822
516

Meaning: Indicates the RSRQ threshold for inter-RAT measurement event A1.
When the measured RSRQ value of the serving cell exceeds this threshold, an event A1 report will be sent.

5.7 Inter-RAT InterRatHoA2ThdRsrp


Value Range: -141~-43
Default Value = -115 (dBm)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1
Eran 2.1

-115
-115
-109

822
513
3

HQ recommended to set as -115.

Meaning: Indicates the RSRP threshold for inter-RAT measurement event A2.
When the measured RSRP value of the serving cell is below this threshold, an event A2 report will be sent.
The value -141 does not take effect and is reserved for backward compatibility. If this parameter is set to -141,
the value -140 is used as the threshold in implementation.

5.8 Inter-RAT InterRatHoA2ThdRsrq


Value Range: -40~-6
Default Value = -24 (0.5dB)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

-24
-24

822
516

Meaning: Indicates the RSRQ threshold for inter-RAT measurement event A2.
When the measured RSRQ value of the serving cell is below this threshold, an event A2 report will be sent.

5.9 Inter-RAT BlindHoA2ThdOffset


Value Range: 0~15
Default Value = 6 (dB)

Eran 3.0

Version

Parameter Value

No Of Cells

Eran 3.0

6
Eran 2.1 do not have this
para

822

Eran 2.1

Meaning: Indicates the offset of the A2 threshold for inter-RAT blind redirection against the A2 threshold
for inter-RAT handovers.

5.10 Inter-RAT InterRatHoUtranB1ThdRscp


Value Range: -120~-25
Default Value = -103 (dBm)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

-103
-103

822
516

Meaning: Indicates the RSCP threshold for event B1 related to coverage-based inter-RAT handover to
UTRAN.
This parameter specifies the requirement for RSCP of the target UTRAN cell.
When the measurement value exceeds this threshold, a measurement report will be sent.

5.11 Inter-RAT CsfbHoUtranB1ThdRscp


Value Range: -120~-25
Default Value = -106 (dBm)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

-106
-106

822
516

Meaning: Indicates the RSCP threshold for event B1, which is used in CS fallback to UTRAN. When CS
fallback to UTRAN is applicable, this parameter is set for UEs and used in the evaluation about whether to
trigger event B1. This parameter indicates the RSCP requirement for the UTRAN cells to be included in the
measurement report. A UE sends a measurement report related to event B1 to the eNodeB when the RSCP in
at least one UTRAN cell exceeds this threshold and other triggering conditions are met. For details, see 3GPP
TS 36.331.

5.12 Inter-RAT InterRatHoA1A2TrigQuan


Value Range: RSRP, RSRQ, BOTH
Default Value = RSRP

Version
Eran
Eran
Eran
Eran

3.0
3.0
2.1
2.1

Parameter Value

No Of eNodeBs

RSRP
BOTH
RSRP
BOTH

273
1
170
2

Meaning: Indicates the quantity used to evaluate the triggering condition for the inter-RAT measurement
event A1 or A2. The values are RSRP, RSRQ and BOTH.
The measured RSRP values are stable, varying little with the load, and therefore there is little signal
fluctuation. The measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell
in real time. By default, the reporting quantity for the inter-RAT handover event is BOTH, that is, both RSRP
and RSRQ.

6.Service Throughput

1. Pb
2. ReferenceSignalPwr
3. DELTAOFFSETRIINDEX

6.1 Service Throughput Pb


Value Range: 0~3
Default Value = 1

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

1
1

822
516

Meaning: Indicates the scaling factor index of the Energy Per Resource Element (EPRE) on the
PDSCH. This scaling factor is determined by the value of this parameter and the antenna port. For details, see
3GPP TS 36.213.

6.2 Service Throughput ReferenceSignalPwr


Value Range: -600~500
Default Value = 182 (0.1dBm)

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 2.1

182
182

822
516

Meaning: Indicates the reference signal power of the cell. For details, see 3GPP TS 36.213.

6.3 Service Throughput DELTAOFFSETRIINDEX


Value Range: 1~15
Default Value = 5

Eran 3.0

Version

Parameter Value

No Of eNodeBs

Eran 3.0

5
Eran 2.1 do not have this
para

274

Eran 2.1

Meaning: Indicates the index mapped to the MCS offset for rank indications (RIs) transmitted with data
on PUSCH. The protocol does not recommend the values 13, 14, and 15. If this parameter is set to 13, 14, or
15, If this value is used, the UE performance may deteriorate. For details, see 3GPP TS 36.213.

7.Common Parameter

1.
2.
3.
4.

TIMEALIGNMENTTIMER
PdcchAggLvlCLAdjustSwitch
CceRatioAdjSwitch
DrxAlgSwitch

7.1 Common Parameter TIMEALIGNMENTTIMER


Value Range: SF500(500 subframes), SF750(750 subframes),
SF1280(1280 subframes), SF1920(1920 subframes),
SF2560(2560 subframes), SF5120(5120 subframes),
SF10240(10240 subframes), INFINITY(Infinity)

Default Value = SF10240


Version

Parameter Value

No Of Cells

Eran 3.0

SF10240
Eran 2.1 do not have this
para

822

Eran 2.1

Meaning: Indicates the length of the uplink time alignment timer for UEs in the cell. A UE is considered
not time-aligned in the uplink if the timer expires.

7.2 Common Parameter


PdcchAggLvlCLAdjustSwitch
Value Range: OFF, ON
Default Value = ON

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 3.0

ON
OFF
Eran 2.1 do not have this
para

813
9

Eran 2.1

Meaning: Indicates the switch used to enable or disable closed-loop adjustment to the PDCCH
aggregation level. If this switch is turned on, PDCCH aggregation level is adjusted based on the block error
rate (BLER) of the PDCCH. If this switch is turned off, PDCCH aggregation level is not adjusted based on the
BLER of the PDCCH.

7.3 Common Parameter CceRatioAdjSwitch


Value Range: OFF, ON
Default Value = ON
Default Value = OFF

Eran 3.0
Eran 2.1

Version

Parameter Value

No Of Cells

Eran 3.0
Eran 3.0
Eran 2.1

ON
OFF
OFF

798
24
516

Meaning: Indicates the CCE ratio adjustment switch for the PDCCH. If this switch is turned on, the
resource allocation algorithm of the PDCCH dynamically adjusts the UL and DL CCE ratios within each
transmission time interval (TTI) based on CCE usages in UL and DL. If this switch is turned off, the UL and DL
CCE ratios are not dynamically adjusted.

7.4 Common Parameter DrxAlgSwitch


Value Range: OFF, ON
Default Value = OFF

Version
Eran
Eran
Eran
Eran

Parameter Value

No Of Cells

ON
OFF
ON
OFF

20
254
10
162

3.0
3.0
2.1
2.1

Meaning: Indicates the DRX switch.