Transmission lines
Pipe networks
Measurements
Manifolds and diffusers
Pumps
Transients
School of Civil and
Environmental Engineering
Measurement Techniques
Direct Volume or Weight
measurements
Velocity-Area Integration
Pressure differential
Pitot Tube
Venturi Meter
Orifice
Elbow Meter
school.edhole.com
Electromagnetic Flow
Meter
Turbine Flow Meter
Vortex Flow Meter
Displacement Meter
Ultrasonic flow meter
Acoustic Doppler
Laser Doppler
Particle Tracking
school.edhole.com
Pitot Tube
Stagnation pressure tap
2
V
V1 = 0
z1 = z2
2
V=
( p1 - p2 )
r
Venturi Meter
1797 - Venturi presented his work on the
Venturi tube
1887 - first commercial Venturi tube
produced by Clemens Herschel
Minimal pressure loss
V12
p2 V22
z1
z 2 hL
2g
2g
p1
Yes!
Bernoulli
equation applicable?_______
Why?
school.edhole.com
2
Contraction
2g 2g
4
2
D2
p1 p2 V2
1
2 g D1
p1
V2
p2
2 g ( p1 p2 )
1 D2 D1 4
Q Cv A2
2( p1 p2 )
4
1 D2 D1
Q school.edhole.com
K venturi A2 2 gh
V1D12 V2 D22
Cv is the coefficient of velocity. It
corrects for viscous effects
(energy losses) and velocity
gradients (a).
Orifice
8D
2.5 D
h
Q K orifice Aorifice 2 gh
Q K orifice Aorifice
2p
school.edhole.com
Elbow Meter
Acceleration around the bend
results in higher pressure at
the outside of the bend
Any elbow can be used as the
meter
Needs to be calibrated (no
standard calibration curves
are available)
school.edhole.com
V2
Fc m
r
Q K elbow Aelbow 2 g h
magnet
conductive fluid
electrodes
measure voltage here
school.edhole.com
nd
S
V0
L 4.3d
Displacement Meter
Used extensively for measuring the quantity
of water used by households and businesses
Uses positive displacement of a piston or
disc
Each cycle of the piston corresponds to a
known volume of water
Designed to accurately measure
slow leaks!
school.edhole.com
Sound velocity
school.edhole.com
Transmitted frequency
http://www.sensorsmag.com/articles/1097/flow1097/main.shtml
school.edhole.com
school.edhole.com
Point measurement
_______
Questions to Ponder
Will an ADV need to be recalibrated if it is moved
from freshwater to saltwater?
A graduate student proposes to use an LDV in a
wave tank (through a glass bottom) that is
stratified with freshwater on top of saltwater to
measure turbulence from the breaking waves.
What problems might arise?
How could the flow normal to the plane of the
light sheet be estimated using PTV?
Would it be possible to know the direction of the
school.edhole.com
flow in the 3rd dimension?
Orifice Example
Estimate the orifice diameter that will result in a 100 kPa
pressure drop in a 6.35 mm I.D. pipe with a flow rate of
80 mL/s. The orifice coefficient (Korifice) is 0.6.
What is the ratio of orifice diameter to pipe diameter?
If the smallest pressure differential that can accurately be
measured with the pressure sensor is 1 kPa, what is the
smallest flow that can accurately be measured using this
orifice?
What are two ways of extending the range of
measurement to lower flows?
school.edhole.com
Orifice Solution
Estimate the orifice diameter that will result in a
100 kPa pressure drop in a 6.35 mm I.D. pipe
with a flow rate of 80 mL/s. The orifice
coefficient (Korifice) is 0.6.
Q K orifice Aorifice
d=
2p
4Q
p K orifice
2 Dp
r
school.edhole.com
d=
pd2
Q = K orifice
4
2Dp
r
4 (80 10 - 6 m3 / s )
p (0.6)
2 (100000 Pa )
1000kg / m3
d = 3.46mm
Orifice Solution
What is the ratio of orifice diameter to pipe
diameter? (0.546)
If the smallest pressure differential that can
accurately be measured with the pressure sensor is
1 kPa, what is the smallest flow that can
accurately be measured using this orifice?
pd2
Q = K orifice
4
2Dp
r
8 mL/s