OME200301 GSM BTS
Trouble Shooting
ISSUE 3.0
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 2
References
M900/M1800 Base Station Subsystem
Troubleshooting Manual
M900/M1800 Base Station Controller
Technical Manual
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 3
Upon completion of this course, you will be
able to:
Know how to find the fault in BTS
Know the common fault types
Grasp BTS fault disposal method
Know how to prevent the fault
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 4
Chapter 1 General Introduction
Chapter 2 Typical Cases
Chapter 3 BTS Fault Prevention
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 5
Chapter 1 General Introduction
Section 1 The Way To Locate Fault
Section 2 Basic Disposal Method
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 6
The ways to locate faults
Alarm
Alarm console
Alarm box
OMC Shell
Traffic statistics
Drive test
Routine inspection
Customer complain
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 7
Locating fault equipment
If BSC has fault, usually it will affect some Sites or all of Sites
If BTS has fault, usually it just affect itself and the handover
success rate of adjacent cells
During implementation or expansion, we can Interchange
BTS and judge whether the fault is because of BSC or BTS
During maintenance, BSC faults dont just affect one BTS
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 8
Common fault types
BTS fault
Antenna & Feeder
Transmission
Hardware connection fault
Hardware fault




HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 9
Chapter 1 General Introduction
Section 1 The Way To Locate Fault
Section 2 Basic Disposal Method
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 10
Basic disposal method
Analyzing the Alarm Information
Alarm information come from the BSS alarm system, indicated
usually through sound, light, LED, and screen output, etc
It includes the detailed description of the abnormality, possible
causes and restoration suggestions, involves the hardware, link,
trunk and CPU loading ratio, etc.. It is a gist for the fault analysis and
location
Analyzing the Indicator Status
Indicators can indicate the work status of circuit, link, optical path,
node and active/standby mode besides that of the corresponding
boards, usually used along with the alarm information generally
Analyzing Traffic Statistics Result
It is the most useful method for locating RNO fault.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 11
Basic disposal method
Analyzing Apparatus & Meter Test Result
It reflects the fault nature with the visual and quantified data
Some common Apparatus & Meter
Signaling Analyzer, Test phone, Sitemaster, etc.
Tracing the Interface
It is applied in locating the failure causes of subscriber call connection
and inter-office signaling cooperation, etc.
The trace result can help to find the cause of call failure directly and
locate the problem or to get the index for the subsequent analysis
Calling Test
It is a simple and quick method to judge whether the call processing
function and relative modules of the BSS are normal or not
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 12
Basic disposal method
Comparison/Interchange
Comparison: compare the faulted components or phenomenon with the
normal ones, and find the differences so as to find the problem
It is usually used in the situation with simple fault range
Interchange: if the fault can not be located even after the standby
components are replaced, you can interchange the normal components
(such as board, optical fiber, etc.) with the potential faulted components,
and to compare the work status so as to specify the fault range or part
It is usually used in the situation with complicated fault range
Switching/Resetting
It can not locate the fault cause accurately, and due to the randomness
of software running, the fault may be not able to recur, thus it is difficult
to know the real fault and solve the problem
This method is just an emergency method, applicable only in the
emergent situation
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 13
Chapter 1 General Introduction
Chapter 2 Typical Cases
Chapter 3 BTS Fault Prevention
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 14
Chapter 2 Typical Cases
Section 1 Antenna & Feeder Fault
Section 2 Transmission Fault
Section 3 Hardware connection fault
Section 4 Hardware fault
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 15
BTS feeder system structure
TX
RX
RXD
T
R
X
CDU
TTA Feeder
TTA Feeder
arrester
optional
Antenna
arrester
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 16
Common faults
Type Fault phenomena
On downlink signal
No downlink signal
MS fails to access the network, calls
cannot be established, call drop, TRX idle
for a long time
Downlink signal
weakened
Poor conversion quality, BTS coverage
shrink
On uplink signal
No uplink signal Calls cannot be established
BTS sensitivity
weakened
Poor conversation quality, BTS coverage
shrink
Feeder system faults
Standing wave alarm Standing wave alarm occurs at CDU
LNA alarm LNA alarm occurs at CDU
TTA alarm TTA alarm occurs at CDU
TTA feeding fails
No DC feeding voltage at CDU antenna
port after TTA configuration
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 17
Common faults on downlink
Description
No downlink signal
Downlink signal weakened
Analysis
No downlink signal
Step1: View the history alarms and real-time alarm at OMC
or local maintenance console
Step2: If there is emergent standing wave alarm at CDU, it is
the most possible cause for which TMU turns off the
transmitter power amplifier resulting in no downlink signal
check the standing wave ratio at jumper side of CDU
antenna port
If the standing wave ratio is beyond limits, locate the
faulty point segment by segment
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 18
Common faults on downlink
Analysis
No downlink signal
Step3: Since there is no downlink signal, there must be a
broken point in the RF signal path. If this point is located at
the part from CDU antenna port to tower top, then CDU
should be able to detect the emergent standing wave alarm.
Otherwise, it can be concluded that the broken point is
located between TRX output to CDU antenna point
Check whether the cable connection between CDU TX-
COM and TX-DUP is correct
Step4: If the operations above fail to locate the failure,
change the CDU
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 19
Common faults on downlink
Analysis
Downlink signal weakened: The symptom of this failure is that
the coverage of BTS or carrier shrinks. Follow the steps below to
handle this problem:
Step1: Check whether the output power of TRX is normal.
Step2: Check whether the standing wave ratio at jumper side
of CDU antenna port is normal.
Step3: Check insertion loss of CDU transmitting path.
Step4: Check whether the connectors involved in the RF
signal path are tightened
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 20
Common faults on uplink
Description
No uplink signal
BTS sensitivity weakened
Analysis
No uplink signal
Step1: Try another antenna feeder (CDU excluded) which has proven
to be normal to substitute the one without uplink signal
If the uplink signal at the new feeder recovered while the one at
the original feeder fails, then the original antenna feeder has
problems
If the phenomenon remains, then CDU has problems. Check
whether the cable connection between RXD OUT and HL_IN or
between HL_OUT and HL_IN is correct
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 21
Common faults on uplink
Analysis
No uplink signal
Step2: If the failure cannot be located yet, change the CDU, and
make the related record ;
Notes: Restore the antenna feeder connection to it original
status
When changing the antenna feeder, make sure that:
The two corresponding antenna feeders should be in the same
cell/sector
The antenna connection should be restored to the original
status after locating the failure. Otherwise, the coverage of the
cell may be affected. This is the basic principle to obey when
using this method to locate the problem
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 22
Common faults on uplink
Analysis
BTS sensitivity weakened
If TTA is configured, first check whether there is any TTA alarm
If so, the TTA is working abnormally
Otherwise, check the CDU antenna port feeding
If no feeding is detected, then the CDU is faulty and needs to
be changed
If DC voltage is normal, then it is considered that the TTA is
normal
After confirming that TTA is normal, check the standing wave ratio
of antenna feeder
If it is too large, then the connection of antenna feeder RF path
is poor or something else
If the standing wave is normal, check the performance of CDU
receiving channel, such as gain and noise factor
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 23
Common faults on uplink
Analysis
BTS sensitivity weakened
The common faults can be located by adopting the
methods above. But it is inevitable that there are some
problems which can not be located by this method since
it is not a comprehensive test. For example, if the gain
decrease and noise factor increase of TTA is not
reflected in the working current, the problem cannot be
detected
On such occasions, make clear records of the
operations which have been done so far for further
analysis
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 24
Common faults on feeder system
Description
CDU alarm (SWR, TTA)
Analysis
Standing wave alarm
Check the SWR of antenna feeder (CDU excluded). If it is lower
than 1.5, while CDU SWR alarm has been generated, this alarm
should be regarded as a mis-alarm, and the CDU needs to be
changed
If the SWR is higher than 1.5, it is necessary to adjust the
connection of antenna feeder until it is lower than 1.5
The installation specification requires the SWR be lower than1.3
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 25
Common faults on feeder system
Analysis
TTA alarm
CDU measures the TTA feeding current through the antenna port. If
the current is not in the normal TTA working current range
(45~170mA), CDU generates TTA alarm
If the feeding current is normal while there is TTA alarm, then it can
be considered as a TTA mis-alarm. Use another CDU to substitute the
faulty CDU. Keep the faulty CDU for further analysis.
If the feeding current is beyond limits, TTA is faulty and needs to be
changed
For the migration site, it is also necessary to confirm the type of
lightning arrester when using TTA
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 26
Chapter 2 Typical Cases
Section 1 Antenna & Feeder Fault
Section 2 Transmission Fault
Section 3 Hardware connection fault
Section 4 Hardware fault
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 27
Transmission Fault
Description
Alarm console
BIE board PCM loss of sync., LAPD_OML alarm
Traffic Statistic console
The handover successful rate, call drop rate of the cell
is abnormal
Consumer complaint
Cannot take a call, bad quality, call drop
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 28
Transmission Fault
Possible causes
Transmission device, board or E1 is faulty
More transmission device, more fault
Transmission code is different (use CRC4 or not)
E1 connection quality is bad
It will cause bad quality, even transmission broken
High BER (bit error rate)
Microwave, HDSL transmission, especially in rainy
weather
The grounding system is faulty
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 29
Transmission Fault 1: E1 broken
Handling process
Probably the reason may be that the E1, transmission device or board is
faulty
Step1: perform self-loop test over BTS and check whether the LIU
indicator of the TMU board is OFF. If no, it can be considered that
the problem lies in TMU board. Please replace TMU board
Step2: perform self-loop test over BSC and check whether the E1
indicator of BIE board is OFF. If not, it can be considered that the
problem lies in the transmission device
Step3: check the transmission NM and check whether a transmission
related alarm is given. Based on the alarm (if any), you may judge
whether the problem lies in the transmission device
Step 4: if neither of them is faulty, it can be considered that the
problem lies in the cooperation between the transmission device and
BSC (or BTS)
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 30
Transmission Fault 2: OML alarm frequently
Handling process
Generally the reason maybe that the E1 grounding is not
good, it cause interference, or transmission device is faulty
Check the TMU in the BTS to check E1 grounding
settings
Test the resistance of the E1 connector and that of the
rack to measure the insulation situation
Check whether the E1 connector in the DDF (when
configured) is grounded
Check whether the E1 enclosure of the transmission
device is grounded
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 31
Transmission Fault 2: OML alarm frequently
Handling process
Check whether the system is in the single-point-grounded state. If
not, modify the system to the single-point-grounded state, then
check whether the trouble is removed
If the trouble is still not removed after the above measures, it may
be considered that the problem lies in the transmission device, E1
or E1 interface board. Check the connection and perform loop test
segment by segment to locate the fault
Check the transmission NM and check whether a transmission
related alarm is given. If yes, please handle it as the related alarm
details
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 32
Typical case: OML broken for E1 grounding error
Description
A sites OML was frequently interrupted and the indicator
(corresponding to the E1) at BSC flashed
The equipment room was located at the top of a 300m-high hill. The
microwave transmission equipment room was 20m away
On the site, the maintenance engineer found the following
The E1 was grounded, as was checked from the DIP switch
The E1 connector was insulated from the cabinet enclosure.
The working grounding cable of the rack was connected with
that of the equipment room
The DDF, an all-metal frame, was connected to the grounding
cable of the equipment room. The E1 connector contacted the
metal of the DDF
No lightning arrester was configured for the E1
The E1 indicator flashed fast
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 33
Typical case: OML broken for E1 grounding error
Handling process
Step1: self-loop the E1 at the top of BTS cabinet and found the
indicator of the E1 cable was OFF. It means BTS is OK.
Step2: self-loop the E1 on the DDF and found the indicator of the E1
cable was OFF. It means the E1 from BTS to DDF is OK
Step3: self-loop the BSC on the DDF and found the E1 indicator is
OFF. It means the E1 from BSC to DDF is OK
Step4: power the TMU off and then on, the trouble still existed
Step5: remove the E1 from the DDF, the trouble still existed
Step6: disconnect the E1 at the top of BTS cabinet, power off the rack
and removed the TMU. Test the resistance between the cabinet-top
E1 connector case and the grounding cable of the rack and found they
were insulated from each other (normal)
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 34
Typical case: OML broken for E1 grounding error
Handling process
Step7: change the TMU DIP switch that corresponded to the
grounding of the E1 cable to OFF (ungrounded), the trouble still
existed
Step8: remove the E1 connector from the DDF and change the
TMU DIP switch that corresponded to the grounding of the E1
cable to OFF (ungrounded). The trouble disappeared
Step9: for confirming the reason, replace the TMU (with the E1
cable ungrounded). Let the E1 connector case contact the DDF
and found the TMU E1 indicator flash fast
Restored the TMU to the original one and removed the E1
connector from DDF, the trouble disappeared
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 35
Chapter 2 Typical Cases
Section 1 Antenna & Feeder Fault
Section 2 Transmission Fault
Section 3 Hardware connection fault
Section 4 Hardware fault
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 36
Typical case: VSWR alarm for cable broken
Description
On BTS maintenance console, one TRX board in a sector was red, alarm
console showed TRX VSWR alarm.
The site was just established
On the site, the maintenance engineer found the following
The RF cable between TRX and CDU was well connected
The RF jumper in the CDU was well connected and also the
connection was right
The RF cable between CDU and lightening arrester was well
connected
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 37
Typical case: VSWR alarm for cable broken
Handling process
Step1: check all the connection from TRX to main feeder and
lightening arrester detailed and also re-tighten all the connections , the
problem was still there, meant the connection had no problem
Step1: connect the CDU in current sector to the antenna in another
sector that was ok before, the TRX was still red, that meant the
antenna and feeder system had no problem , recovered the connection
Step2: connected the TRX to a CDU in another sector that had nothing
alarm before, the TRX was still red, that meant the problem was in the
TRX side, recovered the connection
Step3: change the faulty TRX to a new one, the TRX was still red ,
meant the TRX had no problem, recovered the connection
Step4: change the cables between the TRX and CDU , problem
disappeared . The problem was that the cable was broken during
transport
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 38
Chapter 2 Typical Cases
Section 1 Antenna & Feeder Fault
Section 2 Transmission Fault
Section 3 Hardware connection fault
Section 4 Hardware fault
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 39
Typical case: site failed for TRX fault
Description
A site had no traffic and customer complained that they could not
make a call
It was a omni-directional site and had only one TRX
On the site, the maintenance engineer found the following
All the boards was well in place and the indicators showed
that all the boards had no alarm
Antenna and feeder was well connected
The whole site was well grounded
The power supply had no problem
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 40
Typical case: site failed for TRX fault
Handling process
Step1: checked OMC alarm console , found radio link alarm in the
site
Step2: checked OMC BTS maintenance console, no boards was
red
Step3: queried all the boards software, all were correct
Step4: changed the TMU board to a new one, problem was still
there, recovered it.
Step5: reset TRX and changed all the connections to the TRX to
new one , problem was still there, recovered it
Step6: changed the TRX to a new one , problem disappeared,
meant the problem was in TRX
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 41
Chapter 1 General Introduction
Chapter 2 Typical Cases
Chapter 3 BTS Fault Prevention
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 42
BTS fault prevention
nip the fault
in the bud
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 43
Hardware: installation specifications is most important!
give more attention to E1 connector
give more attention to feeder connector
give more attention to waterproofer of antenna and feeder system
Confirming the grounding and lightning protection

BTS fault prevention
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 44

Checking Running status
BTS maintenance console
First, do multi-site fault query, then try to remove the fault
according to the alarm description and suggestion. if you
cannot remove the fault at provisionally, confirm the reason of
every fault at least
Do calling test for every timeslot
BTS fault prevention
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 45
Summary
In this course ,we have learned how to
Find the fault
Judge the fault
Locate the fault
Remove and prevent the fault

www.huawei.com
Thank You