Product Introduction
M2000 Basic Function
Fault Management
Performance Management
Configuration Management
Topology Management
Security Management


HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 3
Configuration Management Fault Management
Security Management
Security
strategy
protect
detect
respond
DOS
Black list
authentication
encrypt
access
control
insulate
Alarm
Strategy
change
firewall
Log
Performance Management
Topology Management
Basic Features
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 4
Fault Management
Fault Management Features
Browse and Query alarm information
Alarm Remote Notify
Synchronization of alarms
Displacement of alarms
Alarm Acknowledgement
Clear alarms manually
Alarm statistics
Fault correlation analysis
Management of alarm knowledge database
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 5
Browse Alarm
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 6
Browse Alarm

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 7
Alarm Management
a. Current Fault Alarm (Fault Query Fault Alarm (Checklist box) Query Tab


HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 8
Alarm Management (Contd)
b. Event Alarm (Fault Query Event Alarm (Checklist box) Query Tab)

c. History Fault Alarm (Fault Query History Fault Alarm (Checklist box)
Query Tab)

d. Realtime Fault Alarm (Fault Current Fault Alarm Browser (Checklist box)
Query Tab)

e. Realtime Event Alarm (Fault Event Alarm Browser (Checklist box)
Query Tab)


HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 9
Current Fault Alarm

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 10
Event Alarm

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 11
Browse Current Fault Alarm by Status

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 12
Browse Current Fault Alarm by Status

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 13
Acknowledge Alarm
The alarm acknowledgement function helps to
identify alarms. After you acknowledge an
alarm manually, the M2000 displays the alarm as
acknowledged. In this way, you can easily
distinguish between the alarms processed manually and
those to be processed.
This status, however, only indicates that the alarm is
currently acknowledged. It does not
indicate that the alarm is cleared.
How ? Select the query alarm, right click an choose
ack.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 14
Product Introduction
M2000 Basic Function
Fault Management
Performance Management
Configuration Management
Topology Management
Security Management


HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 15
Performance Management
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 16
Measurement Management

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 17
Measurement Status

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 18
Measurement setting

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 19
Query Result (object setting)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 20
Query Result (counter setting)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 21
Query Result (other setting,.time segment, save as template)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 22
Performance Result

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 23
Synchronize Result

www.huawei.com
Thank You

Potrebbero piacerti anche