Configuration Operations
2.5.1 Logging In to an NE
2.5.2 Modifying the NE ID
2.5.3 Configuring IF Protection
2.5.4 Setting IF Attributes
2.5.5 Setting RF Attributes
2.5.7 Configuring Service
2.5.7 Configuring SNCP Service
2.5.8 Converting service
2.5.9 Alarm
2.5.10 Performance
2.5.11 Communications and Security
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 2 Page 2
Web LCT Configuration Logging In to an NE
Step1 Double-click the T2000 Web LCT shortcut icon on the desktop to launch the
T2000 Web LCT.
Step2 The User Login screen is displayed. Enter the user name and password. Click
Login.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 3 Page 3
Web LCT Configuration Logging In to an NE
Create an NE in one of the following two ways.
1. Click NE Search and specify the search criteria. Select the NE to be added
to create a new NE.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 4 Page 4
Web LCT Configuration Logging In to an NE
2. Create an NE directly. Click the Add NE and Enter the information
of the NE and create the NE.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 5 Page 5
Web LCT Configuration Logging In to an NE
Step 4: In the NE List, select the target NE and click NE Login.Then, the IE
displays the NE Login dialog box.
Step 5:Enter the User Name and the Password. Then, click OK.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 6 Page 6
Web LCT Configuration Modifying the NE ID
Step 1 In the NE Explorer, choose Configuration > NE Attribute from the
Function Tree. Click Modify NE ID.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 7 Page 7
Web LCT Configuration Modifying the NE ID
Step 2 Enter a new ID and click OK.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 8 Page 8
Web LCT Configuration Modifying the NE ID
Step 3 In the NE list, delete the original NE. Create a new NE with the new
ID.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 9 Page 9
Web LCT Configuration Configuring IF Protection
The supported IF protection is 1+1 HSB, 1+1 SD, and 1+1 FD.
Create IF protection

Step 1 In the NE Explorer, choose Configuration > IF 1+1 Protection
from the Function Tree.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 10 Page 10
Web LCT Configuration Configuring IF Protection
Step 2 Click New and enter the information of the IF protection. Click OK or
Apply.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 11 Page 11
Web LCT Configuration Configuring IF Protection
Perform IF protection external switching. The priorities of external
switching commands are as follows: clear, lockout, force, and manual.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 12 Page 12
Web LCT Configuration Setting IF Attributes
You can set the following IF attributes by using the T2000 Web LCT:
working mode, link ID, IF port loopback, 2 Mbit/s wayside service, and
ATPC-related information.
In the NE Explorer, select an IF board and choose IF Interface from the
Function Tree.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 13 Page 13
Web LCT Configuration Setting IF Attributes
You can enable automatic transmit power control (ATPC), and adjust
the threshold and the ATPC adjustment.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 14 Page 14
Web LCT Configuration Setting RF Attributes
By using the T2000 Web LCT, you can query and configure the following
RF attributes: transmit frequency, T/R spacing, transmitted power, ODU
manufacturer information, RF loopback status, and ODU status.
Frequency attributes
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 15 Page 15
Web LCT Configuration Setting RF Attributes
Power attributes
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 16 Page 16
Web LCT Configuration Setting RF Attributes
ODU manufacturer information
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 17 Page 17
Web LCT Configuration Setting RF Attributes
In the Advanced Attributes tab, you set RF loopback and ODU status.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 18 Page 18
Web LCT Configuration Configuring a Service
This operation is applicable to VC4, VC3, and VC12 services.
Procedure
Step 1 In the NE Explorer, Configuration -> Cross-Connection
Configuration from the Function Tree.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 19 Page 19
Web LCT Configuration Configuring a Service
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 20 Page 20
Web LCT Configuration Configuring a Service
Step 2 Click New, enter the information of a service and click OK or Apply.


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 21 Page 21
Web LCT Configuration Configuring an SNCP Service
This operation is applicable to VC12, VC3, and VC4 SNCP services.
Procedure
Step 1 In the Cross-Connection Configuration window, click Create SNCP.
Enter the information of an SNCP service.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 22 Page 22
Web LCT Configuration Configuring an SNCP Service

Step 2 After you create an SNCP service, the window is divided into two
panes. The upper pane displays the working service and the lower pane
displays the protection service. You can perform external switching for the
working and protection services.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 23 Page 23
Web LCT Configuration Converting a Service
The T2000 Web LCT supports the conversion between a normal service
and an SNCP service.
To convert a normal service to an SNCP service, select a normal
service, right-click and choose Convert to SNCP from the shortcut
menu. Enter the source of the service in the protection channel and
click OK.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 24 Page 24
Web LCT Configuration Converting a Service
You can convert the working or protection channel of an SNCP service to a
normal service.
To convert a working channel, right-click the service in the working channel
and choose SNCP Working Service Change to Normal Service from the
shortcut menu.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 25 Page 25
Web LCT Configuration Converting a Service
To convert a protection channel, right-click the service in the protection channel
and choose SNCP Protection Service Change to Normal Service from the
shortcut menu.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 26 Page 26
Web LCT Configuration Alarm
By using the T2000 Web LCT, you can view the current and history
alarms, the reporting status of alarms for an NE and boards, and
abnormal events.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 27 Page 27
Web LCT Configuration Performance
The T2000 Web LCT supports 15-minute and 24-hour performance
monitoring intervals.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 28 Page 28
You can view the current and history performance data, UAT events,
threshold crossings, and performance monitoring status. You can set the
performance threshold and reset a board registry.
Web LCT Configuration Performance
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 29 Page 29
Web LCT Configuration Communications
The RTN 600 uses the OSP NE platform.
You can set multiple protocol stacks, including the OSI, IP, and
HWECC.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 30 Page 30
Web LCT Configuration Communications
For DCC management, an IF board supports the configuration of
different DCC rates in different working modes.
When the working mode is PDH, the configuration of one-byte DCC
(D1-D1) rate is supported.
When the working mode is SDH, the configuration of D1-D3, D4-D12,
D1-D12, and D1-D1 is supported.