ISSUE
Case Analysis
ZTE Proprietary & Confidential
2006, ZTE Corporation. All rights reserved. 2
Reason: 1. The antenna feeder cable of PA channel 0 is not well connected. (feeder cable broken, water soaking in) 2. Frequency range of RRU DL signal is out of RFE frequency range. Measurement: 1. Make sure RRU central frequency is correctly configured according to the requested frequency range written on RRU equipment label. 2 Change feeder cable or redo the feeder cable waterproof disposal. 3 Reset RRU and the alarm would be disappeared, if not disappeared, changed RRU
Reason: 1. R6 link off 2. Abnormal VSWR will cause WDPA channel to be closed. 3. GPS antenna link broken. 4 WDPA Board has been manually shut off by setting it Disable 5 WDPA hardware problem
Measurement: 1. make sure the link from MPXM to AGW. MPXM IP configuration right? Transmission ok? 2. check the VSWR value by siteMaster. 3 GPS work normal 4 WDPA board setting enable by manually on OMC Alarm. 5 change RRU
RRU Tx0/Tx1 auto calibration failure
RRU can not detected from omc ,but can find one alarm The board type is not consistent with that configured on OMC
R9100(2x4)
R911048
WPTR
TRWC_B
RRU antenna mode configured at OMC is beyond the actial antennasupporting ability of the type of RRU in the system
R91104 8 TRWC_B 24 or 48
Case Analysis
Case1: How to check the RRU working normal if no any alarm on OMC?
Case1: How to check the RRU working normal if no any alarm on OMC?
Case1: How to check the RRU working normal if no any alarm on OMC?
Case1: How to check the RRU working normal if no any alarm on OMC?
Case1: How to check the RRU working normal if no any alarm on OMC?