Placement of nozzles in process equipment

By Pramod Dixit

Type of process equipment


Columns Heat exchangers Air fin coolers Tanks Vessels Separators Bullets and spheres

Understanding tray geometry


(most of the time controversy arises in columns being complex)

Nozzle Types
Process nozzles Instrumentation nozzles Utility connections Safety connections ( safety valves, rupture disc) Man-holes and hand holes

Process Nozzles
Feed Intermediate Liquid or Vapor or Mixed feed Reboiler liquid outlet Reboiler vapor inlet Reflux inlet Product outlet Sampling connection

Maintenance & Utility Nozzles


Manhole Hand hole Drain Steam Nitrogen

Instrument Nozzles
Level Gauge Level controller Temperature Gauge / transmitter Pressure Gauge/ transmitter Differential pressure recorders/ transmitter Level switch Safety valve

PG / TG connections
Pressure gauge Thermowell to be in liquid . Pressure measuring nozzle in vapor phase always

Thermowell

Thermowell

Placement of PG & Thermowell


Pressure gauge, 6 to 8 below the tray

Thermowell preferred, in down comer 4 above the tray

Alternate thermowell 2 above tray plate

Feed inlet devices #1

Mix feed or vapor feed

Feed inlet devices (shoepetentor)

Schoepentoeter
(used for low Pressure drop & even distribution mostly in vacuum columns)

Structured packing

Feed inlet

Partial liquid withdrawal

Seal Pan

Draw off pan

Partial liquid withdrawal nozzle to be flush with pan plate

Intermediate Liquid feed for high delta T case


Insulating plate for avoiding temperature shocks

Bottom levels

Vapor in

LT

LG

Partial withdrawal from a chimney tray

Partial draw off nozzle

Manhole to see that man can enter in the column

Reboiler return to column (preferably to be parallel to seal pan)


Both are Wrong way
Right way

Vapor stream should not directly hit the seal pan

Reboiler return to column

Prefer Vapor inlet parallel to seal pan

Manhole & hand hole


Manhole ( a suggested spacing 900mm min for man to enter)

Hand holes One at top of packed bed for filling the packing Other at lower level for packing removal

Placement of demister

Manhole Size min18

Multi layer distributor


Such distributors need larger head room for a man to work in side based on the design

Nozzle close to Demister

Small vertical vessels

Level instruments to clear the legs

Air fin cooler bundle

Process Inlet

Process outlet

Air fin coolers

Stacked heat exchanger

Floating Head Exchanger


Multi purpose connection Channel inlet Cover vent

Cover drain

Fixed tube sheet with bellows


Bellow vents

Nozzle jacket

Pv-Rv on Fixed roof tank


PVRV valve

Manhole 600 above bottom plate

JET MIXER in Tank

Jet nozzles

CFD of Jet mixing

Swirl type jet mixer

LPG Mounded bullet


.

Mounded bullet outlet

LPG outlet nozzle

Fire proofing & water spray on bullet dome


Nozzles on Bullet Dome

Fireproofing on Bullet Dome

3 Phase separator

Cut section of 3 phase separator

Skid mounted 3 phase separator

Setting of level instruments in 3 phase separator


Vessel shell Range for ILG & ILT Weir
HH water H igh water NLL water Low water Low low water LLL oil HHL Oil NLL oil LL oil

Set points of level switches Range for LG & LT

Separator ready for dispatch

Thank you