Total head : m
200
100
up to 326 kgf/cm2 up to 320 m up to 6,840 m3/h up to 420 deg.C 2 to 16 in 2900,1450,3500, 1750 rpm up to 2,500 kW up to 11 kV
50
326
HLAV K type
255 224
20 10
HLV H type
100
1000 3 Q:m h
7000
HLAV C type
133 102
Capacity
Tuticorin 2x500MW : 370 deg.C x 214 kg/cm2
Design Temperature : C
High voltage application (up to 10kV) Contributes to power saving for the whole plant
MOTOR WINDING
BEARING BRACKET THRUST BEARING PLATE THRUST BEARING SEGMENT (LOWER)
FILTER
Simple Structure
Nozzle
Nozzle orientation
Suction nozzle is arranged axially (end suction) and the discharge nozzle radially.
The nozzle can be provided with welding stub ends.
Direct connection of the pump and pipeline
Nozzle
This vertical pump is suspended in the pipe line without any external supports.
No anchorage point in the piping system. Casing
The motor unit, together with the heat barrier and the impeller, can be removed from the casing after unscrewing the tiebolts.
Motor
Bearings
Casing
The motor casing is flange-jointed to the pump casing. Glandless design Pump and motor pressure depends on the system pressure.
Casing
Bearings
Bearings
Bearings
The axial thrust is balanced by a self-lubricated thrust bearing.
Thrust Bearing
Axial Bearing
Phenolic Resin SUS420J2 HCr Plated
Bearings
The axial thrust is balanced by a self-lubricated thrust bearing.
Standard type
Forged casing
Cast casing
Spherical casing
Volute casing
Annular casing
Heat barrier
Heat barrier
A heat barrier is provided between the pump and the motor. The heat barrier prevents heat transfer from the hot pump to the cold motor. The heat barrier protects the motor winding insulation. Heat barrier cooling water also prevents heat transfer especially stand-by mode
Insulation class : Y Motor design temp. : Max 90degC
Motor
The HP cooling water inside the motor is circulated by a thrust bearing plate.
The motor heat is transmitted to the LP cooling water in the motor cooler.
Stator Rotor
Motor winding
(Stator coil) Insulation class : Y Design temp. : 90 deg.C Insulation material : Polyethylene
Filter
Filter
2. Operating Data
2.1 Pump set - Pump name - Number of sets per unit - Product number - Designation - Design pressure - Design temperature - Pump - Motor - Hydrostatic test pressure
Boiler Water Circulating Pump 3 set/unit Tuticorin 2x500MW AP930016/ AP930024 Glandless Circulating Pump 214 kgf/cm2 370 deg.C 90 deg.C 321 kgf/cm2
2. Operating Data
2.2 Pump - Type - Fluid pumped - Operating temperature - Capacity - Total head - NPSH req. - Nominal size - Suction nozzle - Discharge nozzle
Vertical Glandless Centrifugal Pump Boiler water 355.5 deg.C 2987 m3/h 31.04 m 15 m OD457.2 mm OD371.5 mm
2. Operating Data
2.3 Motor - Type Wet motor - Nominal rating 350 kW - Nominal speed 1,470 rpm - Frequency 50 Hz - Voltage 3,300 V - Nominal current 89.7 A - Starting current 539 A - Insulation of motor winding PE2/PA (cross link polyethylene/polyamide) - Motor normal temp. 50 deg.C (at upper motor cavity) - Motor alarm temp. 63 deg.C (at upper motor cavity) - Motor trip temp. 66 deg.C (at upper motor cavity)
2. Operating Data
2.4 LP Cooling Water - Heat Barrier - Cooling water quantity required 30 L/min - Inlet temperature 39 deg.C - Cooling water pressure required Approx. 1 kgf/cm2
- Motor Cooler (Over 400kW Torishima supply) - Quantity of heat to be eliminated 41kW - Cooling water quantity required 150 L/min - Inlet temperature 39 deg.C - Cooling water pressure required Approx. 1 kgf/cm2