Centrilift

The GCS Menu system


GCS Drive Setup
Menu group contains most of the parameters that need to be set and maintained for a basic VSC installation

GCS Modules
Screens used to enable, calibrate or scale built-in inputs, outputs & optional external I/O modules including Tracker

Datalog & History


Section provides screens to access the historical data and graphs that are recorded within the GCS controller

GCS Modules Analog Setup


Screens used to calibrate and display measured analog signals including Volts and Amps

GCS Drive Setup Status Custom User Screen

Datalog & History Faults & Undld Prog Logic Funct Faults & Underload
Menus used to enable or disable & adjust timing of most conditions that cause motor shutdowns

Analog Setup & Display SCADA & Security & System

SCADA, Security & System


Menus to enable security passwords, set real-time clock & adjust telemetry parameters

Custom User Screen


Provides access to customized user display screens

Programmable Logic Functions


Menus used to access standard control algorithms and create customized functions based on available inputs and outputs

Centrilift

Centrilift

GCS DRIVE SETUP


The Contrast Adjust screen is accessed by pressing the left and right arrows at the same time.

Centrilift

Centrilift

GCS DRIVE SETUP


The Utility menu screen is accessed by pressing the up and down arrows at the same time.

Utility Menu

Set Frequency Add parm to status Add to Custom User Screen Capture 00 Rename this Parameter

, 310 01 01

Replaces one of the two STATUS menu parameters with the parameter above

Centrilift

Centrilift

GCS DRIVE SETUP


This screen allows you to rename any parameter

Centrilift

Centrilift

GCS DRIVE SETUP


The GCS Setup menus provide access to most of the parameters that need adjustment during routine setup and maintenance
Centrilift
5

Centrilift

GCS DRIVE SETUP 1


GCS Setup 1
Most of the application specific setpoints are found within these menus Factory default values based on drive model number

Centrilift

Centrilift

GCS DRIVE SETUP 2


GCS Setup 2
Second setup screen is accessed by the left or right arrow keys from GCS setup 1

Centrilift

Centrilift

GCS DRIVE SETUP 2


GCS Setup 2
Scroll down when more parameters than can be shown at one time. User password setpoint located here

Centrilift

Centrilift

GCS DRIVE SETUP 2


GCS Setup 2
Frequency Avoidance Submenu Any frequencies entered are active

Centrilift

Centrilift

GCS DRIVE SETUP 3


GCS Setup 3
Torque Control Setup Parameters Only visible with PCM8.xx and higher Nameplate current & Magnetizing current must be set

Centrilift

10

Centrilift

GCS DRIVE SETUP 3

For ESP and ESPCP Motors 30 % of Nameplate Ft-Lbs= HP X 5252 3500

Centrilift

11

Centrilift

GCS DRIVE SETUP


STARTS Fourth screen of GCS Drive Setup menu group Automatic restart parameters and time delays
Centrilift
12

Centrilift

Datalog and History


Accesses the recorded history stored within the GCS controller Includes screens for SHUTDOWN , RUNNING, EVENT HISTORY AND GRAPHING

Centrilift

13

Centrilift

Datalog and History


Shutdown History Records the cause, date and time of last 99 shutdowns.

Centrilift

14

Centrilift

Datalog and History


Shutdown Detail Records a snapshot of the volt, amp and analog measurements at shutdown

Centrilift

15

Centrilift

Datalog and History


EVENT RECORDS
Records all events that occur Events include: Start Ups Setpoint Changes Shutdowns

Centrilift

16

Centrilift
BFC CFN CNL CNR EXC FDC IPL MNC MXC

Datalog and History

BIT FIELD CHANGE (ONE BIT OF A STATUS WORD) CHANGE FROM NORMAL (POTENTIAL FAULT) CITIBUS NODE LOSS (SERIAL COMMUNICATION FAILURE) CITIBUS NODE RECOVERY (SERIAL COMMUNICATION RESTARTED) EXPONENT CHANGE FACTOR DEFAULT CHANGE (CHANGE OF INITIAL FACTORY SETTING) INITIAL PROGRAM LOAD (POWER UP) MINIMUM CHANGE MAXIMUM CHANGE

Centrilift

17

Centrilift
RTC RTN SDE SPC SPR SUE UNC UNE

Datalog and History

REAL TIME CLOCK CHANGE RETURN TO NORMAL SHUT DOWN EVENT (STOP) SETPOINT CHANGE SETPOINT RELOAD (POWER UP) START UP EVENT UNITS CHANGE UNKNOWN ERROR

Centrilift

18

Centrilift

Datalog and History


Running History Accumulates and records runtime statistics

Centrilift

19

Centrilift

Datalog and History


Datalogging Setup
Enables / Disables logging data to PC Card Entry to data log configuration screens
Centrilift
20

Centrilift

Datalog and History


Graphing
GCS controller records motor current for seven day period Minimum, Maximum and average current recorded every 1 min. Stored every week on memory card

Centrilift

21

Centrilift

Datalog and History

Graphing
Graph time from 3hr to 1 week Choice of Graph End, Graph Beginning, or Crsr for reference

Centrilift

22

Centrilift

Datalog and History


Phase B amp chart
B Ampchart 24 hr
80

[...................................................

Strt 00/02/01

Crsr 00/02/01

Min: 40 Max: 45

Centrilift

23

Centrilift

Datalog and History


Graphing

(VORTEX GCS ONLY)


Vortex GCS records 3 current and voltages at 600 samples/sec. for two seconds after startup
Centrilift
24

Centrilift

Faults and Alarms


Access to system protection setpoints, thresholds and time delays Contents of menus vary depending on type of GCS controller

Centrilift

25

Centrilift

Faults and Alarms


Overload
Setpoint represents the maximum amount of current allowed Highest amps is the maximum current on any phase

Centrilift

26

Centrilift
4

Faults and Alarms

P.U. Time

Overload Trip Characteristics

1.5

2.5

3.5

P.U. Current

27 Centrilift

Centrilift

Faults and Alarms


Aux Restart Parms
Use Instead of Global Settings Number of Restarts Restart Delay

Centrilift

28

Centrilift

Faults and Alarms


Underload
Setpoint represents the least amount of current allowed

Centrilift

29

Centrilift

Faults and Alarms


Input Over Voltage
Monitors maximum input voltage Customer scaleable input voltages

Centrilift

30

Centrilift

Faults and Alarms


Input Under Voltage
Monitors minimum input voltage Customer scaleable input voltages

Centrilift

31

Centrilift

Faults and Alarms


Input Voltage Unbal.
Monitors input voltage for unbalance Setpoint 0-100%

Centrilift

32

Centrilift

Faults and Alarms


Low Speed Trip
Protects against operating the motor & pumping system below a safe running frequency
Centrilift
33

Centrilift

Faults and Alarms


Temperature Sensors
The GCS Electrospeed has seven sensor inputs Shutdown thresholds are all factory set, except auxiliary

Centrilift

34

Centrilift

Faults and Alarms


Temperature Sensors The auxiliary sensor input can be used to measure the temperature of a users selected location
35

Centrilift

Centrilift

Faults and Alarms


Telemetry Fail
When enabled, monitors loss of serial communication

Centrilift

36

Centrilift

Faults and Alarms


Alarm Setup
Provides a convenient way to determine which alarms are enabled Use individual alarm screens to edit other parameters

Centrilift

37

Centrilift

Programmable Logic Functions


This menu group provides access to any available programmable functions

Centrilift

38

Centrilift

Programmable Logic Functions


Programmable Function Setup
Two programmable functions are included in basic drive
Centrilift
39

Centrilift

Programmable Logic Functions


PID controller setup
ProportionalIntegral-Derivative closed loop control is a commonly used industrial algorithm

Centrilift

40

Centrilift

Custom User Screen


Customer enters up to eleven parameters of particular interest

Centrilift

41

Centrilift

Custom User Screen


Example of Custom User Screen

Centrilift

42

SCADA & SECURITY & Centrilift SYSTEM


Provides access to a variety of system maintenance, security, communications and time keeping functions

Centrilift

43

SCADA & SECURITY & Centrilift SYSTEM


System
Reset setpoints & prepares controller for re-deployment Some setpoints are not accessible in the field

Centrilift

44

SCADA & SECURITY & Centrilift SYSTEM


SCADA Setup This menu screen allows the user to adjust the parameters controlling serial communications
Centrilift
45

SCADA & SECURITY & Centrilift SYSTEM


Serial Com Diagnostic Screen Receive Buffer Transmit Buffer Com stats

Centrilift

46

SCADA & SECURITY & Centrilift SYSTEM


Provisions for three levels of password protection and security time out setting

Centrilift

47

SCADA & SECURITY & Centrilift SYSTEM


Security Level Access
Level 1: Level 2: Start Most Others Stop Set Frequency Data Logging En. Resetable Run Time Code Enable: Reset History Database RTClock Alarm Enable

Centrilift

48

SCADA & SECURITY & Centrilift SYSTEM


Current Time Menu displays the present value of the onboard, real time, battery backed clock
Centrilift
49

SCADA & SECURITY & Centrilift SYSTEM


Set Time This screen is used to edit and correct the setting of the real time clock

Centrilift

50

Centrilift

Analog Setup & Display


Access to the parameters related to the default analog measurements: Current Voltage Power Factor
Centrilift
51

Centrilift

Analog Setup & Display


Analog Setup
Electrospeed GCS is factory calibrated for finite model ranges Vortex GCS allows the flexibility to accommodate a wide variety of load sizes 52 Centrilift

Centrilift

GCS Modules
Access to calibration and setup of built-in general purpose analog & digital i/o Expansion modules are calibrated via these menus

Centrilift

53

Centrilift

GCS Modules
Onboard I/O is built-in general purpose analog and digital inputs Expansion I/O cards will provide a simple method to expand any system
54

Centrilift

Centrilift

GCS Modules

Status screen shows all detected slaves on CITIBus

Centrilift

55

Centrilift

GCS Modules

Trident status screen if present

Centrilift

56

Centrilift

GCS Modules
Onboard I/O Electrospeed and Vortex GCS both provide two general purpose analog input channels
Centrilift
57

Centrilift

GCS Modules
Hi Threshold Setup
Similar to Fault Setup Aux Restart Params available

Centrilift

58

Centrilift

GCS Modules
Lo Threshold Setup
Similar to Fault Setup Aux Restart Params available

Centrilift

59

Centrilift

GCS Modules
Onboard I/O Electrospeed GCS has three general purpose digital (status) inputs Vortex GCS has two status inputs 60
Centrilift