Sei sulla pagina 1di 60

ENERCOV SYSTEMS

Humidity Control Concept

By

YF Yap
Enercov Co.

1.

Humidity Control Concept

ENERCOV (SUZHOU) Co Ltd Block B, B6-7, Suhong Ind Square, #81 Suhong West Road, Suzhou Industrial Park, JiangSu, China 215021 ENERCOV (THAILAND) Co Ltd 52/1 Moo 13 Krungthep-Kreeta Road, Sapansung, Bangkok 10250 Thailand ENERCOV (SINGAPORE) Co Ltd 80 Genting Lane #06-02, Genting Block, Ruby Industrial Complex, Singapore 349565

2.

3.

We are
Humidity Control Concept

TEMPERATURE , HUMIDITY & CONTROLS

SPECIALISTS

Presentation Details 1. 2. 3. 4. 5. 6. 7. 8. 9. Company Policies Desiccant Application Enercov Application Enercovs Control System Enercovs Components Proposals to NTU Job References Conclusion Questions & Answers

Humidity Control Concept

Company Policy
Humidity Control Concept

1. Assist our customers to reach the best solution for your needs. 2. Design your unit. 3. Use Good Quality Components. 4. Assemble and Start Up. 5. Provide Good After Sales Service. 6. Customer Satisfaction.

Humidity Control Concept

Desiccant Application

Desiccant Wheel
Humidity Control Concept

Humidified Exhaust Air

Outside Air

-------------------------------------------------Humidified Room Air Dehumidified Air into CleanRoom

Desiccant
Advantages 1. It can be used for very low Room Dew Point Temp < 4 deg C 2. It can be used to achieve RH < 10% Disadvantages 1. High Power Consumption due to Heating Element. 2. Steps control and not analog. 3. High Maintenance Cost. Need to change filter and Desiccant. 4. Loose Desiccant can contaminate the supply air . 5. Need big floor space.

Humidity Control Concept

Humidity Control Concept

ANNUAL SAVINGS

Humidity Control Concept

ENERCOV
means

ENERGY RECOVERY

Humidity Control Concept

DX Coil

Evaporator Coil

ENERCOV SYSTEM
Chilled Water Coil
Humidity Control Concept

Evaporator Coil

Condenser Coil

Semi Hermetic Compressor

Refrigeration Cycle Diagram


Humidity Control Concept

Psychometric Explaination

Humidity Control Concept

Outdoor Condition

Heating

Room Condition

DX Coils
Humidity Control Concept

Advantages 1. Uses Energy Recovery. Very little energy wasted. 2. VSD control. Analog Control. 3. Most cost effective to control RH above 30%. 4. Low Maintenance Cost. Wash the coil with water. 5. No contamination to supply air due to no direct contact media. 6. DX coils is build into the AHU. Need less space. Disadvantages 1. Limitations to control RH below 30% RH due to minimum suction gas temp of 3 deg C.

ITS SOUND SIMPLE


Humidity Control Concept

BUT ALL THIS THINGS

IS NOT COMPLETE WITHOUT

TOTAL CONTROL

Conventional Air Conditioner & Desiccant Control


1. Room RH Sensor Activate when RH above 55%. 2. Signal send to DDC. 3. Activate to ON the Desiccant Unit. 3 stages heater in Desiccant Unit fully ON. 4. RH of Room Drops to 50%. Then , 1 stage heater OFF. 5. Once RH drops below 45% , 3 stages heater OFF. 6. Once RH above 55% , 3 stages heater ON again. 7. This system uses STEP CONTROL and NOT ANALOG CONTROL. 8. MOST IMPORTANTLY Control DEHUMIDIFICATION & COOLING SEPARATELY.
Humidity Control Concept

Biosafety Laboratory Concept Humidity Control Concept

Conventional Air Conditioner

Humidity Control Concept Humidity Control Concept

RESULTS WITH ENERCOV SYSTEM

RESULTS WITH ENERCOV SYSTEM


Humidity Control Concept

Before we can start to CONTROL


Humidity Control Concept

We must know

What

are the

CONTROL MODE

Process of the Air


Humidity Control Concept

Humidification

Cooling

Heating

Dehumidification

ENERCOV SYSTEM
Humidity Control Concept

CONTROL Dehumidification, Cooling, Heating & Humidification to keep Temperature and Relative Humidity of the ROOM as CONSTANT as POSSIBLE.

ENERCOV Humidity Total Control Concept

Humidity Control Concept

DX COILS Hot Gas Reheat, Hot Gas Bypass, VSD & DDC Controls System

High Quality Components Used


Humidity Control Concept

1. 2. 3. 4. 5. 6.

Air Handling Unit Carrier, Robatherm, etc Humidity Control Unit Carlyle Compressor CAREL Controller, Panel & Sensors CAREL Steam Humidifier Others

Humidity Control Concept

CARRIER AHU

Humidity Control Concept

HUMIDITY CONTROL UNIT

CAREL CONTROLLER, PANEL & SENSORS


Humidity Control Concept
DDC PROGRAMMABLE 4 x 20 LCD Display

Temperature & Humidity Sensor Pco1 Controller

Humidity Control Concept

CAREL STEAM HUMIDIFIER

Humidity Control Concept

We would like to Proposed to the

TOP MANAGEMENT of NANYANG TECHNOLOGICAL UNIVERSITY ( NTU )

PROPOSE ENERCOV SYSTEM


Enercov Unit AHU

AND

ENERCOVS CONTROL
CONTROLLER, PANEL & SENSORS
Humidity Control Concept
DDC PROGRAMMABLE 4 x 20 LCD Display

Temperature & Humidity Sensor Pco1 Controller

Humidity Control Concept

SCHEMATIC DIAGRAM

ENERCOV CONTROL ITEMS


1. Two sets of Sensors Temperature & Humidity One at Supply Air and One in the Room. 2. Solenoid Valve to Control The Reheat Coil. 3. Control Valve to Control Chilled Water Coil. 4. Solenoid Valve to Control the HotGassBypass. 5. Temp Sensor for Air Off Chilled Water Coil. 6. Temp Sensor for Air Off DX Cooling Coil. 7. Others
Humidity Control Concept

Humidity Control Concept

Control Points Schedule

Psychometric Process

Humidity Control Concept

ENERCOV
DX Heating Coil

ENERCOV FLEXIBILITY
Humidity Control Concept

DX Cooling Coil
Total Cooling Sensible Heat Rat Sensible Heat Latent Heat 31.58 kW 0.51 16.1 kW 15.5 kW

Chilled Water Coil


48.4 kW 0.94 45.5kW 2.9kW

Range for Sensible Heat Range for Latent Heat

9.1 kW to 61.6 kW 0.58 kW to 18.4 kW

ENERCOV SYSTEM
Humidity Control Concept

CONTROL Dehumidification, Cooling, & Heating to keep Temperature and Relative Humidity of the ROOM as CONSTANT as POSSIBLE.

Humidity Control Concept Humidity Control Concept

RESULTS WITH ENERCOV SYSTEM

TOTAL CONTROL
Humidity Control Concept

TEMPERATURE 22 +/-1 deg Celcius


and

RELATIVE HUMIDITY 40%-50% RH

Humidity Control Concept

JOB REFERENCES

JOB REFERENCES
Humidity Control Concept

1. Takeda Lace Co Ltd Bangkok. 2. Biological Safety Lab Level 3 in Ministry of Health Thailand. 3. NSM Factory Co Ltd. 4. UL & CE Standard Testing Room Bangkok. 5. Ministry of Medicine Thailand Vaccine Production Class 10000.

1. Takeda Lace Co Ltd


Humidity Control Concept

Temperature 24 deg C +/- 1 deg C Relative Humidity 65% +/- 2% RH DDC micro processor based control system Steam Humidifier capacity control Cooling / Heating / Dehumidification / Hum are controlled in proportional linearity.

Humidity Control Concept

Takeda Lace Co Ltd

2. Biological Lab Safety 3 Ministry of Health Thailand


Humidity Control Concept

Temperature 23 deg C +/- 1 deg C Relative Humidity 50% +/- 5% RH Room Pressure Clean Room - 20 Pa Room Pressure Clean Room + 20 Pa 100% Outdoor Air Intake DDC micro processor based control system Hot gas bypass system

Biological Lab Safety 3 Ministry of Health Thailand


Humidity Control Concept

Biological Lab Safety 3 Ministry of Health Thailand


Humidity Control Concept

CONTROL POINT DIAGRAM FOR BSL-3 LABORATORY FACILITY DATE : 15-SEP-2003

?2 ?C ?10 %rh

3. NSM Factory Co Ltd


Humidity Control Concept

Temperature 27 deg C +/- 1 deg C Relative Humidity < 40% RH Double series evaporator coils system Hot gas by pass system DDC micro processor based control system

Humidity Control Concept

4. UL & CE Standard Testing Room ( Air Conditioner Performance Testing Room 12000 - 72000 Btu/Hr )
Room Temperature Error +/- 1 deg C Room Humidity Error +/- 5% RH Steam Humidifier capacity control Cooling / Heating / Dehumidification / Hum are controlled in proportional linearity.

UL & CE Standard Testing Room

Humidity Control Concept

UL & CE Standard Testing Room


Humidity Control Concept

Humidity Control Concept

5. Vaccine Production Clean Room Class 10000


Room Temperature < 22 deg C Room Humidity 50% +/- 10% RH Room Pressure 10 20 Pa GMP Clean Room Class 10000 Air Change per Hour 30 Cooling / Heating / Dehumidification / Hum are controlled in proportional linearity.

Vaccine Production Clean Room Class 10000


Humidity Control Concept

Humidity Control Concept

CONCLUSION

TOTAL CONTROL ON THE TEMPERATURE & RELATIVE HUMIDITY


Humidity Control Concept Humidity Control Concept

SUMMARY OF ENERCOV SYSTEM


1. CONTROL TEMPERATURE & RH by CONTROLLING COOLING, HEATING, DEHUMIDIFICATION SILMULTANEOSLY. 2. USES MICROPROCESSOR CONTROL. 3. HAVE MORE THAN 20 POINTS SENSOR & CAN BE ADJUSTED TO MEET DESIRED TEMPEARATURE & RH OF THE ROOM. 4. USER FRIENDLY. 5. ASSURANCE THAT TEMPERATURE 22 C +/- 1 deg C. 6. ASSURANCE RELATIVE HUMIDITY 40% - 50% RH.

Humidity Control Concept

ENERCOV is providing a BRAIN


for the Air Conditioning System to
Humidity Control Concept

CONTROL the Temperature 22 -/+ 1 deg C and Relative Humidity 40 - 50% RH & Save at least 70% Energy Compare To Desiccant Unit

ITS our JOB to PROTECT

THE EARTH
for the FUTURE of OUR CHILDREN

SAVE ENERGY

Thank you