INTRODUCTION
Average output voltage can be varied by controlling the triggering input to the SCR gates in suitable manner. The three gate pulses are displayed by 120 relative to each other, giving same delay angle to each SCR. Each SCR conducts for 120 after triggering and remain off for 240.
Firing angle is measured from the intersection of corresponding phase voltages and not the zero crossings of the voltage waves.
When is varied, the segments of phase voltage that fabricate the load voltage change, providing a control over the average value. Negative output of load voltage are possible, depending upon the nature of load.
For resistive load 0<=<=30, output voltage is continuous. 30<=<=120, output voltage is discontinuous and has some intervals in which output voltage is zero. >150, output is zero.
Trigger angle, = 0
Period 30 - 150 150 - 270 270 - 390 ON Switch SCR1 SCR2 SCR3 OFF Switch SCR2 & SCR3 SCR1 & SCR3 SCR1 & SCR2 Vo VAN VBN VCN Switch Voltages VSCR1 VSCR2 VSCR3 0 VBA VCA VAB VAC 0 VBC VCB 0
ON Switch
SCR1 SCR2 SCR3
OFF Switch
SCR2 & SCR3 SCR1 & SCR3 SCR1 & SCR2
Vo
VAN VBN VCN
Trigger angle, = 60
Period 90 - 180 210 - 300 ON Switch SCR1 SCR2 OFF Switch SCR2 & SCR3 SCR1 & SCR3 Vo VAN VBN Switch Voltages VSCR1 VSCR2 VSCR3 0 VBA VCA VAB 0 VCB
8
330 - 420
SCR3
VCN
VAC
VBC
30
60
90
120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570 600
11
OFF Switch
13
0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570 600
THREE PHASE HALF-WAVE CONTROLLED RECTIFIER WITH INDUCTIVE LOAD AND FREE-WHEELING DIODE
14
30
60
90
120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570 600