MX100 Introduction

March 2003

MX100 Regional Training

Product LOGO

March 2003

MX100 Regional Training

MX100 Hardware Components


Base Plate
Different size for 1 to 6 modules.

I/O Modules

Main Module

March 2003

MX100 Regional Training

MX100 Main Module


Data acquisition engine controlling up to 6 I/o modules in one system.

Operating Mode indicator Dip SW Compact flash memory card slot for data backup
Change operating mode

Ethernet 100-Base-TX,10Base-T Auto-switch


March 2003 MX100 Regional Training

I/O Module
4ch High-speed universal input module 10ch Medium-speed universal input module

10ch High-speed digital input module

10ch digital output module

Fastest measurement interval : 10ms In of case TC/RTD, fastest measurement interval is 50 ms Input : DCV/TC/RTD/DI
March 2003

Fastest measurement interval : 100ms Input : DCV/TC/RTD/DI

Fastest measurement Interval : 10ms

Output interval :100ms Output : SPST relay (make contact)

Input DI

MX100 Regional Training

MX100 Features
PC Font-end System allowing Flexible Construction High Speed & Multi-channel Measurement
4ch module with 10msec measurement interval 10ch module with 100msec measurement interval Scalable from 4 channels to hundreds channels 3 individual sampling speed can run in one system

High Withstand Voltage (Reinforced Insulation)


3700Vrms(1minute), 600Vrms/Vdc(working voltage)
between input terminal and case

Data Protection

Open Architecture, Others

Compact flash card for back-up the data while communication down Modular construction 100Base-TX Ethernet standard Disconnect-able terminal, external screw terminal

March 2003

MX100 Regional Training

PC Front-end
To Network

Up to 20 units with MXLOGGER - 24ch/10msec - 300ch/100msec - 1200ch/1sec


100Base-TX

Base plate

Input/output module

Main module with Ethernet, Compact flash card slot

March 2003

MX100 Regional Training

Scalable
From 1 module model to 6 module model can be Configured according to measurement channels

March 2003

MX100 Regional Training

Multi Measurement Interval


3 individual sampling speed in one system

Setting example

10msec

100msec

10sec

Measurement intervals are set separately for each module.

March 2003

MX100 Regional Training

Common Mode Voltage Performance


(Double Insulation)

Vmax=600Vrms/Vdc from ground in case of 1 system.

Module(n/10)
CH(n) CH(n-1) n=600/V1

CH(n-9)

Vmax=600Vrms/Vdc between modules

CH10

n * V1

2 * V1 V1

CH2 CH1

Module1

- In case of 10ch module, 150VACrms(50/60Hz) is a maximum noise voltage between channels in one module. And, the voltage between channels in one module is also restricted by IEC1010 6.3. - In case of 4ch module, 250Vrms/Vdc is a maximum voltage between channels in one module
March 2003 MX100 Regional Training

Common Mode Voltage Performance


(Double Insulation)

A Module A

Comparison table between Darwin and MX100


V1, V3 V2
250Vrms/Vdc 2300Vrms, 50/60Hz 120Vrms/Vdc (SELV 250VACrms noise voltage, 50/60Hz) 1000Vrms, 50/60Hz 120Vrms/Vdc (SELV 150VACrms noise voltage, 50/60Hz) 1000Vrms, 50/60Hz

V3
V3

V2 V2

B Module B

10ms AI (4ch)

Allowable Common mode Voltage Test Voltage (1min)

600Vrms/Vdc 3700Vrms, 50/60Hz 600Vrms/Vdc

V1 V1

100ms AI (10ch)

Allowable Common mode Voltage

Test Voltage (1min)

3700Vrms, 50/60Hz 160Vrms/Vdc (SELV 250VACrms noise voltage, 50/60Hz) 1500Vrms, 50/60Hz

Darwin

Allowable Common mode Voltage

Test Voltage (1min)

March 2003

MX100 Regional Training

Technical Resource
High reliable serial bus with high speed simultaneous data transmission

ASIC

ASIC

3700V withstanding transformer

ASIC

ROM

RAM

Power Iso. Iso. Iso. Iso. SCC CPU SCC SCC SCC SCC CF

Ether net

4ch/10msec AI 4ch/10ms AI
Measurement of true parallel multi-channel CH Synchronizing

10ch/100ms AI 10ch/100msecAI
High breakdown voltage solid state relay

Control unit

3 individual sampling interval in one system


100 Base-TX standard Compact flash standard

March 2003

MX100 Regional Training

Data Back-up with CF Card


Support up to 2G bytes card Start data storage at communication error

Cable error PC power fail, hung-up Others


Re-start data transfer to PC automatically after the communication recovers

Communication File storage

True Fail
PC HD File A MX CF File B

True

PC HD File C

March 2003

MX100 Regional Training

Data Back-up with CF Card


Data Storage length
number of channels measurement interval 10ms 100ms 500ms 2s 10ms 24ch 100ms 500ms 2s 10ms 60ch 100ms 500ms 2s 32M approx. 2 hours approx. 21 hours approx. 4.5 days approx. 18 days approx. 54 minutes approx. 9 hours approx. 45 hours approx. 7.5 days approx. 18 minutes approx. 3.5 hours approx. 18 hours approx. 3 days 128M approx. 9 hours approx. 3.5 days approx. 18.5 days approx. 75.5 days approx. 3.5 hours approx. 37 hours approx. 7.5 days approx. 31.5 days approx. 75 minutes approx. 15 hours approx. 3 days approx. 12.5 days 512M approx. 36 hours approx. 15 days approx. 75.5 days approx. 303 days approx. 15 hours approx. 6 days approx. 31.5 days approx. 126 days approx. 5 hours approx. 2.5 days approx. 12.5 days approx. 50 days

10ch

March 2003

MX100 Regional Training

Disconnect-able Terminal

Disconnect-able!!
Reduce re-wiring time when changing test- target and/or calibration.
March 2003 MX100 Regional Training

External Connectivity

- Screw terminal - Better RJC uniformity


Screw terminal can be used only for 10ch AI module and 10ch DI module.

March 2003

MX100 Regional Training

Others
- Connector cover
- DIN rail mounting

March 2003

MX100 Regional Training

Basic specifications
Main Module
Number of modules, units: Up to 6 modules / 1 main module (10ms 24 ch, 100ms 60 ch/unit) Up to 20 units connectable through MX100 enhanced software Filter: Time constant=Measurement period x N, N=5,10,20,25,40,50,100 Selectable N number depends on measurement period. Interface: Compact flash slot: Alarm (main module): Calculation (main module): 100 Base-TX Type II x 1, Specially designed for memory card 2 levels/ch Difference, scaling

March 2003

MX100 Regional Training

Basic specifications
Analog input module
Number of channels Fastest measuring period Measurement period Input ranges 4 ch high-speed module 10 ch scanner module 4 ch 10 ch 10 ms (50 ms for TC/RTD) 100 ms Up to three types of intervals per system (on a module basis) 10, 50, 100, 200, 500ms, 1, 2, 5, 10, 20, 30, 60s DCV/TC/RTD/DI DCV/TC/RTD/DI DCV : 20mV, 60mV, 200mV, 2V, 6V, 20V, 100V TC : R,S,B,K,E,J,T,L,U,N,W,KpvsAu7Fe RTD : Pt100, Pt50, NI100, NI120, Cu10 etc. DI : Non-voltage contact / Level(5V logic) 1.67ms, 16.7ms, 20ms, 36.67ms, 100ms, 200ms Determined by the measurement period Integration time 16.7ms or longer 0.05% of rdg. + 5digits @2V range 3700VAC(50/60Hz) for 1 min. 2300VAC(50/60Hz) for 1 min. (RTD also isolated) 3700VAC(50/60Hz) for 1 min. 1000VAC(50/60Hz) for 1 min. (b terminal common)

Integration time: Measurement accuracy Withstanding voltage Between input terminal and case Between channels in one module

Digital input/output module


Number of channels Input and output types Measurement/output period March 2003 10 ch DI 10 ch Non-voltage contact/TTL O.C/ Level(5V logic) minimum 10 ms MX100 Regional Training 10 ch DO 10 ch SPST relay minimum100 ms

Differences between MX100 and DA100 (2)


MX100
Shared by the main unit and PC software Main unit: 2 levels/channel Upper/lower limits, upper/lower limits of difference PC software: Implements by combining computation and command DO Rate-of-change alarm implementable Shared by the main unit and PC software Main unit: Difference computation, scaling, software filter PC software: Computation function provided as a standard function Provided as a standard function. Darwin-/M1-level computation possible by the PC software.

DA100
Completely done on the main unit 4 levels/channel Upper/lower limits, upper/lower limits of difference Rate-of-change alarm Completely done on the main unit Difference, scaling, moving average Completely done on the main unit

Aims

Alarm

<>

Flexible alarm system implementable Using the resources of the computation channels

Computation function

>

Optional computation function Report function

<>

Operation expressions easier to understand Constant description Total number of characters (40 250) C-language-like operator

None. Use of the Excel macro, etc. Ethernet only. Initial setup simplified such as automatic detection, automatic setup of IP address, etc. Binary-only format Update through the CF card slot, backing up function when communications disconnected, etc.

<

Provided as an option of /M3 Ethernet, GP-IB, RS232, RS485 ASCII command, binary/ASCII data Simple setup High-speed setup Development of self-made program supported by API Reduced number of communications types Easy serviceability

Communications function

<>

Maintenance

>

None

March 2003

MX100 Regional Training

Differences between MX100 and DA100 (1)


MX100 - PC -Base plate -Control unit -I/O Module DA100 - PC -Basic/enhanced main unit -Subunit -I/O module -Communications module 10ch20ch30ch UniversalmV/TC Single-phase/three-phase power monitor 120ohm /350ohm NDIS distortion DI-input-dedicated, mA input Pulse input Current/voltage analog output Communications Maximum speed of 500 ms Synchronized with the cycle of the slowest module
1500 V

Aims Simple configuration covering a wide range of channels

System configuration

>

Module types

10msAI,100msAI,DI,DO

<

Reducing the module types. Considering the real effects of each module. High-speed measurement Coexistence of high speed and high stability Cell, electrolytic cell Multi-channel measurement

Measurement cycle

Maximum speed of 10 ms Multi-interval of 3 types

>>

Withstand voltage Number of input points


March 2003

3700 V

>>

60 channels/unit 1200 channels/system

<>

60 channels/subunit 300 channels at the maximum More channels connectable with the DAQLOGGER

MX100 Regional Training

MX100 Software Concept


MX Standard Software
- Ready to run control software
-MX100 broadcast search (UDP) and Automatic module/controller detection -Always monitoring, once connection is made, even in background -All hardware options configurable via MXStandard

-Advanced Data logging


-Independently log up to three scan groups -Record/log interval to log every N scans -Manual and Automatic start and stop conditions

-Advanced viewer
-One to Four independent Viewer areas -Mark comment on live data, stored into logfile -Parallel cursors on

-Data Export
-Excel, ASCII, Lotus

March 2003

MX100 Regional Training

MX100 Software Concept


MX Additional Software
-Standalone Viewer
-View and Analyze recorded data -Cursor on all scan groups in parallel -Statistics or export data on selected regions

-MX Calibrator with wizards


-Independently log up to three scan groups -Record/log interval to log every N scans -Manual and Automatic start and stop conditions

-Programming - API
-Programmatically automate any MX measurement -Use C/C++, Visual Basic, or LabVIEW -DLL, VI, OPC support

March 2003

MX100 Regional Training

Software Options
Basic Specifications
Dedicated Software Standard
- One-to-one

Features
- Ready for multi-interval - Computation - Relay Output

connection with the MX (Up to 60 channels per unit) - Setup, monitoring Logging, redisplay
Connected with two or more number of MX units - Setup, monitoring Logging, redisplay Monitor server
-

Enhanced

- Ready for multi-interval - Computation (between the units) - Relay output - Synchronized data processing among two or more number of MX units Saving the man-hours of the users to develop selfmade software

API LabView

Functions for setup and data sampling

March 2003

MX100 Regional Training

Useful features : Distributed data acquisition

MX100 standard software

Dedicated LAN

M.N

T.F

Multi MX connected under same segment network is detected automatically.

Network configuration menu

March 2003

MX100 Regional Training

MX100 standard software


Useful features : Manual DO during monitoring/recording

March 2003

MX100 Regional Training

Combination with DARWIN/DAQSTATION


DAQLOGGER

MXLOGGER Monitor Server

MXLOGGER

March 2003

MX100 Regional Training

Logo of DAQWORX

March 2003

MX100 Regional Training

DAQWORX R1
DAQWORX
VDS InTouch ADDObserver ADDMulti ADDTRigger

OPC

GateOPC

DAQWORX Data Highway

DAQOPC

DAQEXPLORER

DAQLOGGER
I/F

DAQ32+

MX-Log

GateDXP GateWT GateEye GateMODBUS


Network

March 2003

MX100 Regional Training

DAQWORX Roadmap
Mid 2004 DAQWORX R3
Universal Launcher

Feb 2004

DAQWORX R2
Improved installer More value-add AddReport +

Jun 2003 DAQWORX R1


Suite (1 CD)

AddDataManager AddEvent AddWeb GateFA-M3

Today PC Software

MX100 logger AddTrigger GateWT GateEye GateDX-P GateOPC GateMODBUS