Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Technology - VLAN is a method used to logical segment a physical network (IEEE 802.1Q standard) Network separation is achieved by isolation on layer 2 connectivity Delivery of Ethernet packets is restricted to members that belong to the same VLAN A VLAN tag information (VID) is added to network frames either by the host or by the switch Advantages Provides more flexible network deployment over traditional network technology Simplifies network administration and configuration Can improve network performance by separating a network into different segments
VLAN Tagging
Layer 2
Application
data
data
A chunk of data
Layer 2
TCPIP (AIX)
Layer 2
Ethernet Adapter
data
An untagged Ethernet frame (max. 1516 bytes) An a tagged Ethernet frame (max. 1532 bytes)
data
Frame B
en 0
VLAN n
Frame A
Frame B
Frame A
Frame B
en 0
Frame B
AIX LPAR
enx
AIX LPAR
AIX LPAR
AIX LPAR
AIX LPAR
AIX LPAR
AIX LPAR
POWER Hypervisor
Physical Device PCI Eth or LHEA port
POWER Hypervisor
VLAN
VIOS LPAR
Enterprise Network
Enterprise Network
AIX LPAR
enx
AIX LPAR
AIX LPAR
AIX LPAR
TCPIP ROUT ING
AIX LPAR
enx
AIX LPAR
AIX LPAR
AIX LPAR
POWER Hypervisor
Enterprise Network
POWER Hypervisor
Enterprise Network
VIOS LPAR
VLANs
Physical Devices
AIX LPAR
AIX LPAR
AIX LPAR
AIX LPAR
AIX LPAR
entx
entx
entx
entx
entx
V switch B
VLAN X
V switch C
VLAN X
VIOS LPAR
Power6 Server
Physical Device
Enterprise Network
AIX LPAR
en0 (if)
AIX LPAR
en0 (if)
AIX LPAR
en0 (if)
POWER6 Server
POWER6 Server
ent0 (virt)
PVID 118
ent0 (virt)
PVID 218
ent0 (virt)
PVID 318
PHPY
VIOS
VIOS
ent1 (virt)
ent2 SEA
ent0 (phy)
ent2 SEA
ent0 (phy)
To other switch
To other switch
SEA backing device supports: - PCI Ethernet adapter. - Logical host Ethernet Adapter (LHEA)port with promiscuous mode. The only logical port configurable is number 1 on the physical port Corresponding IVE physical port is dedicated for SEA use All the IVE switch bandwidth is assigned to the SEA
AIX LPAR
en0 (if)
ent0 (virt)
POWER6 Server
PHYP
VIOS
ent1 (virt)
ent2 SEA
PCI adapter Or LHEA port with Promiscuous mode
Switch
Two IVE physical ports set to promiscuous mode are required to improve the network connectivity of the SEA.
VIOS
SEA
AIX
Virtual Ethernet Driver
AIX
Virtual Ethernet Driver
LINUX
Virtual Ethernet Driver
AIX
LHEA Driver
AIX
LHEA Driver
LINUX
LHEA Driver
Hypervisor
Network Adapter
LAN IVE communicates directly to logical partitions (LPARs). -- It is physical device, it must before partition mobility. -- Each IVE physical port is separated network Switch. -- It reduces the interaction with POWER Hypervisor. -- 10Gbps IVE feature has better performance than virtual Ethernet. -- IVE supports a maximum of 16 or 32 LPARs. IVE reduces the need for physical Ethernet adapters.
AIX Client
Virt Ent
VIOS 1
Shared Ethernet adapter Physical Ent
Switch
Link Aggregation at VIOS - one primary adapter with one backup adapter Two different switches without extra configuration - Several primary adaptors with one backup All primary adaptors must be connected to the same physical switch Extra configuration on switch is needed - Easy to setup and manage - No special configuration on client partition - single or multiple LANs at client partition Resilience - VIOS partition is a point of Failure Performance - Network bandwidth is increased
Phys Ent
Phys Ent
switch
switch
POWER Server
AIX Client
LINK Agent Primary
backup
ent
ent
ent
LHEA
LHEA
LHEA
LHEA port
LHEA port
LHEA port
IVE Adapter
Phys Port Phys Port Phys Port
Switch
Switch
AIX Client
NIB
Phys Ent Virt Ent
VIOS 1
Shared Ethernet adapter Phys Ent
Switch
Switch
AIX Client
Virt Ent
NIB: Two shared Ethernet adapters in different VLANs with NIB on the client partition Shared Ethernet adapter failover feature. Benefits: --Bridging solutions are easy to setup --No specialized configuration on switch component --Needs two physical Ethernet adapters (one per virtual I/O server
VIOS 1
Shared Ethernet adapter Phys Ent
VIOS 2
Shared Ethernet adapter Phys Ent
Switch
Switch
Needs additional CPU, RAM, and disk for second VIOS partition
VIOS 1
Shared Ethernet adapter Phys Ent
VIOS 1
Shared Ethernet adapter Phys Ent
Switch
Switch
Client LPAR 1
Client LPAR 2
Considerations - Is supported at VIOS 1.2 and above - Has no load balancing for single configuration - Supports VLAN tagging Benefits - Easy client partition configuration - Network configuration simplified compared to the NIB Remarks - The control channel is critical for VIO server synchronization. only one SEA must be active at a time - Two parameters for the support: Priority Control channel
Heart beat
Use DLPAR to add required virtual adapters - control channel, trunk - Minimize downtime NIB configuration removed at later time - Clients IP address is associated with the NIB - Downtime when moving IP address to another interface (short planned downtime on the Client)
Multiple LANs in the client partition: Availability solution Multiple LANs solution is driven by VLAN tagging rules: If only untagged frames are propagated to external network
infrastructure (VLAN unaware hosts) - No VLAN ID administration at AIX and supervisor level - Need to segment traffic in Hypervisor (thru PVID configuration) - Multiple gateway s or SEAs and multiple LANs in virtual switch - Easy network administration, complex virtual architecture. If tagged frames are supported by external switch - AIX and Hypervisor VIDs must be defined according enterprise network architecture - No additional gateway or SEA for multiple VLANs configuration
Thank you