Sei sulla pagina 1di 2

Dual-Band Combiner

806 960 MHz


CDMA 800 / GSM 900

1710 2170 MHz


GSM 1800 / UMTS

Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit DC by-pass between all ports DC stop available as an accessory

Port 3
Port 1

793 532 Single Unit

Port 2

793 533 Double Unit

Typical Attenuation Curves


Single Unit 793 532 Double Unit 793 533 (only 1 unit shown) Diagram I Port 1 Port 3
Attenuation/dB
0 10 2000 2170 20 806 960 30 40 1710 2000

Port 2 Port 3

Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2

793 532
Single Unit

Double Unit

793 533

50 60

806 960 MHz 1710 2170 MHz Typically 0.15 dB (806 960 MHz) Typically 0.25 dB (1710 2000 MHz) Typically 0.35 dB (2000 2170 MHz) > 45 dB (806 824 MHz) > 50 dB (824 960 MHz) > 50 dB (1710 2170 MHz) < 1.2 (806 960 / 1710 2170 MHz) 50 < 250 W < 200 W < 160 dBc (2nd/3rd order; with 2 x 20 W) 55 ... +60 C 7-16 female Indoor or outdoor (IP 66) DC by-pass between all ports (max. 2500 mA) Wall mounting: With 4 screws (max. 8 mm diameter) Mast mounting: With additional clamp set 1.6 kg 3.0 kg 350 x 165 x 138 mm 350 x 165 x 190 mm 125 x 197.7 x 61.2 mm 125 x 197.7 x 111.6 mm (without connectors, without mounting brackets)

70 80 90 100 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500

Frequency/MHz

Diagram II
Port 1 Port 3 Port 2 Port 3

936.2137/f

VSWR Impedance Input power Band 1 Band 2 Intermodulation products Temperature range Connectors Application Special features Mounting Weight Packing size Dimensions (w x h x d)

Attenuation/dB

0 0.1 0.2 0.3 0.4 0.5 0.6 2000 2170 0.7 806 960 0.8 0.9 1.0 500 1710 2000

Subject to alteration.

700

900

1100 1300 1500 1700 1900 2100 2300 2500

Frequency/MHz

Internet: http://www.kathrein.de

793 532, 793 533

Page 1 of 2

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494

Dual-Band Combiner
806 960 MHz
CDMA 800 / GSM 900

1710 2170 MHz


GSM 1800 / UMTS

Accessories (order separately)


Type No. 734 360 734 361 734 362 734 363 734 364 734 365 Type No. 793 301 784 10367 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm
* 61.2* 40.5*

234

coupler 7-16 (3x) Side view 793 532 Single Unit

Clamp Set

M6

31.5

281.8

coupler 7-16 (6x)

DC stop
* *

Description DC stop 50- load 1.5 W indoor or outdoor

Side view 793 533 Double Unit * Valid if labelled Dual-Band Combiner labelled Dual-Band Combiner V1 (not valid for previous version

50- load

Earthing Instruction
Top view 793 532 Single Unit, 793 533 Double Unit

Toothed washer Earthing cable (not included in the scope of delivery) Washer Earthing screw

Torque 6-7 Nm

Bottom view 793 532 Single Unit, 4 screws M5 x 10 4 spring washers 5.5 DIN 6095 793 533 Double Unit

As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of a mast mounted device or even cause it to fall to the ground. These facts must be considered during the site planning process. The Dual-band Combiners are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4. The installation team must be properly qualified and also be familiar with the relevant national safety regulations. The details given in our data sheets have to be followed carefully when installing the antennas, filters, combiners, amplifiers and accessories. The limits for the coupling torque of RF connectors, recommended by the connector manufacturers must be obeyed. Terminate unused inputs with a suitable 50 Ohm load, e.g. 784 10367. Any previous datasheet issues have now become invalid.

Page 2 of 2

793 532, 793 533

Internet: http://www.kathrein.de

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494

936.2137/f

Subject to alteration.

Please note:

The mounting plates of products labelled Dual-Band Combiner V1 can be removed by loosening the screws to (M5 x 10) and replaced with other means of mounting, always provided that the max. drilled depth of 8.5 mm is respected with the choice of replacement screws. If the label deos not contain the suffix V1 then IP66 protection will be lost and all corresponding guarantees will become null and void, if mounting brackets are removed or tampered with.

Potrebbero piacerti anche