Pressure Boosting System

PRESSURE BOOSTING SYSTEMS

1. Definition and Principle of a Booster unit


2. Hyamat Range
3. Hya-Solo Presentation
4. Hyamat K/V/VP modes of operation
5. Hyamat K/V/VP Presentation
6. Equipement
7. Selection of a Booster unit

V34, Productmanagement
Building Services Pumps Seite 1 von 54
10/2004
Pressure Boosting System

Definition

•A booster unit is a device that can increase water system pressure


and ensure consistent pressure during use.

•Water is generally supplied by a municipality.

•There are cases where the user is too far away from the main supply

•Or the user needs more pressure because of the particularity of his installation.

Supplier Municipality Too high! Too far!

V34, Productmanagement
Building Services Pumps Seite 2 von 54
10/2004
Pressure Boosting System

Application

Factories

Hotel & hospital Water supply of building

Reinforcement network of water


Irrigation
Water supply (replacement)

V34, Productmanagement
Building Services Pumps Seite 3 von 54
10/2004
Pressure Boosting System

Pressure Boosting System gives more comfort

V ^ \

No water supply No pressure! A device gives more


pressure

V34, Productmanagement
Building Services Pumps Seite 4 von 54
10/2004
Pressure Boosting System

Pressure Booster unit

V34, Productmanagement
Building Services Pumps Seite 5 von 54
10/2004
Pressure Boosting System

Basic device Pressure gauge


Valve
Pressure Tank

Non return valve

Pump

Control System

Valve

Protection

V34, Productmanagement
Building Services Pumps Seite 6 von 54
10/2004
Pressure Boosting System

Mode of operation of a unit: Basic function

The pump is started up and switched off by pressure gauge

H(m)
80
70
PA
60
50

40
PE
30

20
10

0
0 2 4 6 8 10 Q(m³/h) 12

PE = Start up pressure
PA = Schwitch off pressure

V34, Productmanagement
Building Services Pumps Seite 7 von 54
10/2004
Pressure Boosting System

PRESSURE BOOSTING SYSTEMS

1. Definition and Principle of a Booster unit


2. Hyamat Range
3. Hya-Solo Presentation
5. Hyamat K/V/VP modes of operation
6. Hyamat K/V/VP Presentation
7. Equipement
8. Selection of a Booster unit

V34, Productmanagement
Building Services Pumps Seite 8 von 54
10/2004
Pressure Boosting System

Product Pressure Boosting units

Superbloc: SBC Hya-Solo E Hya-Solo D/DV Hya-Eco


Surpress Eco

Hyamat K Hyamat V / VP
Surpress Feu: SF Surpresschrom SIC Surpresschrom SICV / SICVP

V34, Productmanagement
Building Services Pumps Seite 9 von 54
10/2004
Pressure Boosting System

Pressure Boosting system at a glance: Hyamat

160 160m

140

120

100
85 m Hya-Solo D/DV

80
65 m

60

40
Hyamat K/V/VP
Hya-Eco
20
VP: 200m³/h
Hya-Solo E 7m³/h 45 m³/h 65 m³/h K / V: 360 m³/h
0
1 10 100 Q ( m³/ h) 1000

V34, Productmanagement
Building Services Pumps Seite 10 von 54
10/2004
Pressure Boosting System

Pressure Boosting system: Surpresschrom

160m
160

140

120

100
85 m

80
65 m

60

40 Surpress Feu Surpresschrom SIC/SICV/SICVP

20 Surpress-Eco
VP: 200m³/h
Superbloc 7m³/h 45 m³/h SIC / V: 360 m³/h
0
1 10 100 Q ( m³ / h) 1000

V34, Productmanagement
Building Services Pumps Seite 11 von 54
10/2004
Pressure Boosting System

HYAMAT Range

180
160
140
120
100
Hm

80
60
40
Hyamat Building systems Hyamat Industry
20
0
0 100 160 340 350 500 640
Q m³/h

V34, Productmanagement
Building Services Pumps Seite 12 von 54
10/2004
Pressure Boosting System

Product positioning (multi-pump systems)

Price
Hyamat
VP
V

Hya-Eco

Technology
V34, Productmanagement
Building Services Pumps Seite 13 von 54
10/2004
Pressure Boosting System

PRESSURE BOOSTING SYSTEMS

1. Definition and Principle of a Booster unit


2. Hyamat Range
3. Hya-Solo Presentation
4. Hyamat K/V/VP modes of operation
5. Hyamat K/V/VP Presentation
6. Equipement
7. Selection of a Booster unit

V34, Productmanagement
Building Services Pumps Seite 14 von 54
10/2004
Pressure Boosting System

Hya-Solo

Application: •Fire-fighting systems for residential buildings,


department stores and industrial plants
•Water supply systems for residential and
office buildings
•Irrigation / sprinkling systems
•Rainwater utilisation systems
•Utility water supply systems for industrial plants

Pumped liquid: Drinking water, fire-fighting water, utility water,


cooling water, filtered rainwater containing no
aggressive, abrasive or solid substances.
V34, Productmanagement
Building Services Pumps Seite 15 von 54
10/2004
Pressure Boosting System

Designation Principle for Hya-Solo


Hya-Solo D V / 04 05 / 2 - 4

Type series
E = single-phase a.c. current
D = three-phase current
Speed control
(V = variable with frequency converter)

Pump size
Number of stages
Inlet pressure in bar (for V: from - to)

V34, Productmanagement
Building Services Pumps Seite 16 von 54
10/2004
Pressure Boosting System
HYA - SOLO E

With Movitec VE 2-6 and VE 4-5 Hya-Solo E / 0405

•Type series E
•Pump size 0405
Characteristic:
•Movitec VE
with integrated non return valve
•All wet parts of the pump in stainless steel

Operating data (standard variant):


Pd up to 10 bar
Pinlet up to 3,5 bar
Tliquid up to 70°C
up to 25°C acc. To DIN 1988 (DVGW)
Tambient up to 40°C

Supply voltage
1~230V 50Hz
V34, Productmanagement
Building Services Pumps Seite 17 von 54
10/2004
Pressure Boosting System
HYA - SOLO D/DV

With Movitec V 2m³/h - 65m³/h


Hya-Solo D / 1808 / 0,3

•Type series D, DV
•Pump size 2, 4, 10, 18, 32, 45, 65
•Number of stages
•Inlet pressure (bar)
Characteristic:
•Movitec V
•All wet parts of the pump in stainless steel
Operating data (standard variant):
Pd up to 16 bar
Pinlet up to 6 bar
Tliquid up to 70°C
up to 25°C acc. To DIN 1988 (DVGW)
Tambient up to 40°C
Supply voltage
3~400V 50Hz
V34, Productmanagement
Building Services Pumps Seite 18 von 54
10/2004
Pressure Boosting System

Hya-Solo Selection chart

Movitec
Head

02 04 10 18 45
32

V34, Productmanagement
Building Services Pumps Seite 19 von 54
10/2004
Pressure Boosting System

Hya-Solo

Permissible inlet pressure fluctuations


for Hya-Solo D +0,3/-0,2 bar
for Hya-Solo DV see characteristic curves

The sum of inlet pressure and shutoff head must not exceed 10 bar
for Hya-Solo E and 16 bar for Hya-Solo D/DV.

V34, Productmanagement
Building Services Pumps Seite 20 von 54
10/2004
Pressure Boosting System

Hya-Solo Hya-Solo D/DV 18/32/45/65

Hya-Solo E

Hya-Solo D/DV 4/10

V34, Productmanagement
Building Services Pumps Seite 21 von 54
10/2004
Pressure Boosting System

Design:
Hya-Solo E Fully automatic, package single-pump unit with 8 l
membrane-type accumulator. The unit is started up
depending on the pressure and switched off
depending on the flow.

Hya-Solo D Fully automatic, package single-pump unit. The


unit is started up and switched off depending on the
pressure.

Hya-Solo DV Fully automatic, package single-pump unit with


speed control. The unit is started up depending on
the pressure and switched off depending on the
flow rate.
V34, Productmanagement
Building Services Pumps Seite 22 von 54
10/2004
Pressure Boosting System

Hya-Solo E

The pump is started up depending on the pressure


and switched off depending on the flow
H(m)
60

50
Q1
40

30
PE
20

10

0
0 1 2 3 4 5 6 Q(m³/h) 7

PE = Start up pressure
Q = Schwitch off Flow rate

V34, Productmanagement
Building Services Pumps Seite 23 von 54
10/2004
Pressure Boosting System

Hya-Solo E Integrated swing Reserve volume for low


check valve water withdrawal
quantities, low switching
Low energy consumption frequency thanks to
due to high-efficiency DVGW-approved
hydraulic accumulator

Integrated dry-
running protection
Corrosion-resistant
hydraulic

Easy adaptation to the operating


Installation free from solid- conditions by setting the start-up
borne noise transmission pressure to values from 2 to 3.5
because of elastic elements bar
V34, Productmanagement
Building Services Pumps Seite 24 von 54
10/2004
Pressure Boosting System

Hya-Solo D

The pump is started up and switched off depending on the pressure

H(m)
80
70
PA
60
50

40
PE
30

20
10

0
0 2 4 6 8 10 Q(m³/h) 12

PE = Start up pressure
PA = Schwitch off pressure

V34, Productmanagement
Building Services Pumps Seite 25 von 54
10/2004
Pressure Boosting System

Hya-Solo D/DV
Lack-of-water protection by
Daily functional check run means of the pressure
controlled by timer (option) control device (option)

DVGW-approved
control tank with direct
flow to DIN 4807-5 Fully automatic
control unit

Permanently filled discharge Installation free from solid-


pipe thanks to check valve borne noise transmission
System pressure indicated because of elastic elements
by pressure gauge
V34, Productmanagement
Building Services Pumps Seite 26 von 54
10/2004
Pressure Boosting System

Hya-Solo DV

Speed control system with a single pump started up depending on the pressure
and switsched off on the flow.
H(m)
80

70

60

50

40
PE
30 100%
20
80%
10

0
75%
0 Q1 2 4 6 8 10 Q(m³/h) 12

PE = Start up pressure
Q1 = Schwitch off pressure

V34, Productmanagement
Building Services Pumps Seite 27 von 54
10/2004
Pressure Boosting System

Hya-Solo D/DV 15/30/45

Fully automatic control unit


Daily functional check run
controlled by timer (option)
Corrosion-resistant: hydraulic and
pump shroud made of stainless steel

Membrane-type Lack-of-water protection by


accumulator with means of the pressure control
direct flow to DIN 4807-5 device (option)

Pump can be
System pressure dismantled via flange
indicated by
pressure gauge Permanently filled discharge
pipe thanks to check valve
V34, Productmanagement
Building Services Pumps Seite 28 von 54
10/2004
Pressure Boosting System

PRESSURE BOOSTING SYSTEMS

1. Definition and Principle of a Booster unit


2. Hyamat Range
3. Hya-Solo Presentation
4. Hyamat K/V/VP modes of operation
5. Hyamat K/V/VP Presentation
6. Equipement
7. Selection of a Booster unit

V34, Productmanagement
Building Services Pumps Seite 29 von 54
10/2004
Pressure Boosting System

Standard Pressure Boosting Units (PBU)

1 Pump
2 Ball valve
3 Combined check/shut-off valve
4 Pressure gauge
5 Pressure transmitter
6 Control tank
7 Switch gear

V34, Productmanagement
Building Services Pumps Seite 30 von 54
10/2004
Pressure Boosting System

Hyamat K
Pressure-controlled cascade operation

Two to six pumps are


started up and switched
off by the control unit in
line with the actual
demand.

V34, Productmanagement
Building Services Pumps Seite 31 von 54
10/2004
Pressure Boosting System

Hyamat V
Continuous speed control of one pump

A base load pump is


continuously controlled,
with the peak load
pumps being started up
and switched off in line
with the demand.
set value

V34, Productmanagement
Building Services Pumps Seite 32 von 54
10/2004
Pressure Boosting System

Hyamat VP Continuous speed control of each pump

Continuously variable
speed adjustment of
each pump.
The peak load pumps
are started up and
switched off in line with
the demand.
All pumps run at the set value
same speed.

V34, Productmanagement
Building Services Pumps Seite 33 von 54
10/2004
Pressure Boosting System

Other combinations and control modes


Available on request (example: 1 or 2 jockey
pumps as low load pumps)

V34, Productmanagement
Building Services Pumps Seite 34 von 54
10/2004
Pressure Boosting System

PRESSURE BOOSTING SYSTEMS

1. Definition and Principle of a Booster unit


2. Hyamat Range
3. Hya-Solo Presentation
4. Hyamat K/V/VP modes of operation
5. Hyamat K/V/VP Presentation
6. Equipement
7. Selection of a Booster unit

V34, Productmanagement
Building Services Pumps Seite 35 von 54
10/2004
Pressure Boosting System

Hyamat K / V / VP

Applications: •Residential buildings •Department stores


•Hospitals •Industry
•Office Buildings •Other
•Hotels applications

Pumped liquid: Drinking water, service water,


fire-fighting water, cooling water,
provided that it is neither chemically
nor mechanically aggressive to the
system materials
V34, Productmanagement
Building Services Pumps Seite 36 von 54
10/2004
Pressure Boosting System
HYAMAT K, V und VP

Mit Movitec V von 2m³/h bis 45m³/h


Hyamat K 6 / 1808 / 0,3

•Type series K, V, VP
•Number of pumps
•Pump size 2, 4, 10, 18, 32, 45
•Number of stages
•Inlet pressure (bar)
Characteristic:
•Movitec V
•All wet parts of the pump in stainless steel
Type series
K (pressure-dependent cascade operation)
V (continuously variable speed
adjustment of one pump)
VP (continuously variable speed
adjustment of all pumps)
V34, Productmanagement
Building Services Pumps Seite 37 von 54
10/2004
Pressure Boosting System

HYAMAT K / V

Operating data (standard variant):

Q up to 360 m³/h, 100 l/s


with 6 Pumps max. 1)
H up to 160 m
T liquid up to 70 °C
up to 25° C acc. To DIN 1988 (DVGW)
Tambient up to 40°C
Pd up to 16 bar
Pinlet up to 10 bar

Supply voltage 3/PE, AC 400V, 50Hz

1) with stand-by pump as peak load pump

V34, Productmanagement
Building Services Pumps Seite 38 von 54
10/2004
Pressure Boosting System

HYAMAT VP

Operating data (standard variant):

Q up to 200 m³/h, 55 l/s


with 4 Pumps max. 1)
H up to 130 m
T liquid up to 70 °C
up to 25° C acc. To DIN 1988 (DVGW)
Tambient up to 40°C
Pd up to 16 bar
Pinlet up to 10 bar

Supply voltage 3/N/PE, AC 400V, 50Hz


5-wire mains < 2.2 kW

1) with stand-by pump as peak load pump

V34, Productmanagement
Building Services Pumps Seite 39 von 54
10/2004
Pressure Boosting System

Hyamat K / V / VP

Materials
Pumps Movitec V

suction/discharge casing stainless steel


hydraulic stainless steel
seal FPM 80
plain bearing aluminium oxide
mechanical seal to DIN 24960
spring-loaded ring hard carbon, resin-impregnated
seat ring aluminium oxide
V34, Productmanagement
Building Services Pumps Seite 40 von 54
10/2004
Pressure Boosting System

Hyamat K / V / VP

Materials
Hydraulic

distributor pipe stainless steel


valves copper-base alloys
brass, DVGW-approved
Tank connection made of stainless steel
Membrane approved for drinking water to DIN 4807-5

V34, Productmanagement
Building Services Pumps Seite 41 von 54
10/2004
Pressure Boosting System

Hyamat VP

Features / Benefit
System using a frequency inverter ð High operating reliability in case
for each pump of failure of a pump or frequency
inverter

Synchronous pump operation ð High pressure constancy at


dynamic consumer installations

Fully speed-controlled ð High efficiency due to the capability


pressure boosting unit of the system to use the variable
inlet pressure

Pump and frequency inverter ð Standard products instead of


are separated integrated solutions (control
cabinet muffles frequency
inverter noise)
V34, Productmanagement
Building Services Pumps Seite 42 von 54
10/2004
Pressure Boosting System

PRESSURE BOOSTING SYSTEMS

1. Definition and Principle of a Booster unit


2. Hyamat Range
3. Hya-Solo Presentation
4. Hyamat K/V/VP modes of operation
5. Hyamat K/V/VP Presentation
6. Equipement
7. Selection of a Booster unit

V34, Productmanagement
Building Services Pumps Seite 43 von 54
10/2004
Pressure Boosting System

Start-up and shutdown of up to


Hyamat K / V / VP six high pressure pumps, Even distribution of
as required pump operation
Full enclosure •automatic
(optional) pump changeover
•retrofitting, easy to service
•protects from dirt
•attractive design General fault message
•low-noise approx. 51-61 dB(A) •volt-free contact

Flow goes through


the control vessel
DIN 4807-5,
High reliability
DVGW-approved
•constant monitoring of
the function of the
connected sensors
No structure-borne sound
pumps are uncoupled from Corrosion protection thanks DVGW-approved
the base to stainless steel piping valves
V34, Productmanagement
Building Services Pumps Seite 44 von 54
10/2004
Pressure Boosting System

Flow passing through the accumulator

In drinking water application to


DIN 4807-5, flow must go through
the accumulator.

Piping

V34, Productmanagement
Building Services Pumps Seite 45 von 54
10/2004
Pressure Boosting System

Determination of the volume of an accumulator

V = 275 x Qm x (Pe+1) x (Pa+1)


F x ∆P x (Pg+1) x N H(m)
70

V = Tank volume (liter) 60


Pe = Pressure switch on (bar)
(Pa = 4,5 bar)
Pa = Pressure switch off (bar) 50
Pa
∆P = Pa - Pe (bar) 40
(∆P = 1 bar)

Qm = average flow of the pumpe Pe (Pe = 3,5 bar)


between Pa and Pe (m³/h) 30
F = Motor start allowed per hour
20
Pg = Air Pressure of the tank (bar)
(Pg = Pe-0,5) 10
N = Number of pumps
0
Exemple: for 2 Pumps with F=15 0 1 2 3 4 5 Q(m³/h) 6
V = 199 liter Qm
(Qm = 3,5 m³/h)

V34, Productmanagement
Building Services Pumps Seite 46 von 54
10/2004
Pressure Boosting System

Hyamat VP without or with cladding (optional)

(Surpresschrom SICVP)

V34, Productmanagement
Building Services Pumps Seite 47 von 54
10/2004
Pressure Boosting System

PRESSURE BOOSTING SYSTEMS

1. Definition and Principle of a Booster unit


2. Hyamat Range
3. Hya-Solo Presentation
4. Hyamat K/V/VP modes of operation
5. Hyamat K/V/VP Presentation
6. Equipement
7. Selection of a Booster unit

V34, Productmanagement
Building Services Pumps Seite 48 von 54
10/2004
Pressure Boosting System

Hyamat K / V / VP

V34, Productmanagement
Building Services Pumps Seite 49 von 54
10/2004
Pressure Boosting System

Selection

•A pressure booster units is defined by the flow Pu

rates and the pressure. ΣH


Hs = Static Head...........................................m
ΣH = Head loses (devices, pipes,etc...)........m
Pu = Pressure user.......................................bar
Pressure to produce = Hs+ΣH+(Pux10)
•The pressure after the Booster unit
= Hinlet + Hs + ΣH + (Pu x10) H

Hs
•The flow rates is defined according rules of
calculation given from the norms.
for example:
Hinlet
•DIN1988/5 Germany
•NFP 41101 and DTU 6011 France Pmax=3,3bar
pmin=2,2bar
Booster unit

V34, Productmanagement
Building Services Pumps Seite 50 von 54
10/2004
Pressure Boosting System

Data required for selection of a pressure boosting unit (PBU)

•PBU capacity (Q):


pmax
•Stand-by pump: yes/no
•Start-up pressure for PBU (pE): pmin pE ~
~
•min. inlet pressure upstream of PBU (pmin): PBU
•max inlet pressure upstream of PBU (pmax):
•PBU discharge head (H):
Inlet side H/Q discharge side

•Pressure boosting concepts: Cascade operation /


Speed control of one pump/of all pumps

CAUTION! Do not forget the dry-running protection equipment!

V34, Productmanagement
Building Services Pumps Seite 51 von 54
10/2004
Pressure Boosting System

Pressure Boosting system at a glance

Number of pumps 2 to 3 2 to 6 2 to 6 2 to 4

Capacity m3/h up to 7 up to 65 up to 45 up to 360 up to 360 up to 200

Head (max) m

System discharge
pressure bar

Pipes of stainless steel


no yes yes yes yes yes

Automatic dry-run standard accessory accessory accessory accessory standard


protection

D Cascade
1 pump all pumps
Control DV 1 pump
cascade speed-
cascade cascade speed- speed-
controlled controlled controlled

V34, Productmanagement
Building Services Pumps Seite 52 von 54