Important: Read First Release Notes for ROMeo 6.0.

1
Welcome to the release of ROMeo 6.0.1. Starting with version 6.0, ROMeo, ARPM, MBM, ROMeo Process Opt and ROMeo Utilities Opt are included and accessed as part of the ROMeo Product suite. All documents related to these products are now part of ROMeo documentation. RELEASE 6.0.1 Installation Release 6.0.1 Documentation Where to Find ROMeo Documentation Summary of New Features in 6.0.1 Migration to ROMeo 6.0.1 Summary of Defects Fixed in 6.0.1 Summary of Open Defects and Known Issues in ROMeo 6.0.1 License and Copyright Information 2 2 3 3 5 6 7 10 12

Release Notes for ROMeo 6.0.1

Release 6.0.1
Installation
Installation of ROMeo 6.0.1 patch requires previous installation of ROMeo 6.0 full release. Install full release ROMeo 6.0 before installing 6.0.1 patch. The patch installation will detect if ROMeo 6.0 is installed prior to proceeding with the update to 6.0.1. No license security is required for installing 6.0.1 patch. License security is required for running ROMeo once the patch is installed. Machines that only have the 64-bit solver installed, i.e. there is no v6.0 server installed or 32-bit only solver installed on the system, should not use the standard 6.0.1 install patch executable. A separate install patch executable is provided for 64-bit solver-only install. Patch install kits will only be found on the Electronic Software Distribution (ESD) site on the Invensys Simsci-Esscor Support Webpage under the Software Updates & Knowledge Base. The 6.0.1 install patch and 6.0.1 64-bit solver-only patch are available for download. No additional authorization code is needed to download ROMeo patches. 6.0.1 patch installation files update many previously installed 6.0 files and add some new files. The patch install also updates many initialization and ROMeo system files that may require the user to copy over original customized files. Patch installations do not update license security settings.

Release Notes for ROMeo 6.0.1

Release 6.0.1 Documentation Where to Find ROMeo Documentation


Printed documentation
Release Notes (this document) ROMeo Getting Started Guide and Tutorial ROMeo Users Guide

The ROMeo Getting Started Guide and Tutorial document replaces the ROMeo Installation Guide previously included with full installation kit.

Online documentation
The following online documentation listed below can be found on the distribution CD under the MANUALS directory.
Applibs (Application Libraries) Application Briefs MILANO Users Guide Modular Thermo Reference Manual Process Models Guide ROMeo Installation Guide (same as ROMeo Getting Started Guide and Tutorial) ROMeo Real Time System User Guide ROMeo Users Guide SLV Guide (Solver Guide) Thermo Data Manager Use Guide INSQLEMI Adapter User Guide OPCUA Server User Guide

Application Briefs include the following documents:


Model Application Briefs Solver Application Briefs

Application Libraries include the following ROMeo/ARPM model databases:


P2_AromaticSeparation R3_CrudeOilDistillation G5_ExpanderPlant R5R_FCCMainFractionator P5R_NaphthaleneRecovery

Release Notes for ROMeo 6.0.1

The following documentation that updates the ROMeo Users Guide and ROMeo Real-Time System Users Guide can be found on the ROMeo6.01 patch install kit in the ESD site under the SUPPLEMENTAL USERS GUIDE directory.
ROMeo 6.01 Release Note (this document) ROMeo Advanced Settings User Guide ROMeo Model Building User Guide ROMeo Real-Time System Supplemental User Guide ROMeo Accumulated Release Notes

All user guides previously included as separate documents for supplemental updates to the ROMeo Users Guide have been combined into the ROMeo Advanced Settings User Guide, ROMeo Model Building User Guide and ROMeo Real-Time System Supplemental User Guide. In addition to previously released user guides, the ROMeo Advanced Settings User Guide, ROMeo Model Building User Guide and ROMeo Real-Time System Supplemental User Guide contain additional sections for the following new features and enhancements.
Blend Unit enhancements KBC HCRSIM User Guide for Integrated KBC HCRSIM reactor CH Multi Instance Section in Captive Historian Section of Real-Time System Supplemental User Guide

Contact the Simsci-Esscor Website (www.Simsci-Esscor.com), your local SimsciEsscor representative, or a Simsci-Esscor Technical Support Center for instructions on obtaining documentation about creating custom process models in ROMeo. Ask for the document Process Models in ROMeo: A Guide to Creating Custom Process Models in MILANO. A listing of Technical Support Centers can be found in the ROMeo Users Guide or the ROMeo Installation Guide. Note: The manuals present an overview of the features and functionality available in ROMeo and Modular Thermo. In some cases, the online Help accessible from within ROMeo or the ROMeo Real Time System will contain more detailed information on process unit data entry and technical questions regarding specific process models and subsystems.

Release Notes for ROMeo 6.0.1

Summary of New Features in 6.0.1


New features added since 6.0.

KBC SimSuite 3.3 HCRSIM Reactor


See additional information in HCRSim Reactor UserGuide.pdf

Captive Historian Multiple Instances


See additional information in ROMeo_Real_Time_System_Supplemental_User_Guide.pdf

Enhance Blend Unit to support User control of blending of NBP, MWT, and SPGR (LFRM#15811)
Provide ability to avoid component property MW, SpGr and NBP in the blend unit from updating thermo.

Support Sensitivity Analysis for large models (LFRM#15673)


Improve memory use for enabling ROMeo users to perform sensitivity analysis on larger models.

Solver Presenter Trend Excel 2010 report (LFRM#15728)


Support Solver Presenter Trend report with Excel 2010 Template.

Release Notes for ROMeo 6.0.1

Migration to ROMeo 6.0.1


Thermo enhancements in upgraded versions of ROMeo may cause flowsheet to produce open residuals after schema evolution migration. New thermo enhancements may also produce better thermo calculations. Solving and updating initial values for portions of migrated flowsheet may be required to improve flowsheet initialization prior to full flowsheet solve.

Moving Custom Reports to ROMeo 6.0.1


To open Custom Reports created in previous versions in v6.0.1, user should copy the folder User\Mra\ModelReportViews from the previous build to the new build folder User\Mra\ModelReportViews.

Migrating Captive Historian Tags to ROMeo 6.0.1


Users are required to export the Captive Historian configuration to a file before uninstalling the previous version. The user can then Import the configuration file into the ROMeo 6.0.1 Captive Historian Admin Tool.

Migrating databases to ROMeo 6.0.1


ROMeo\ARPM\MBM model application databases in v5.0x, v5.1x, v5.2x, v5.3 and v6.0 will automatically migrate (through schema evolution) upon opening in ROMeo 6.0.1. Real-Time System sequence database in v5.0x, v5.1x, v5.2x, v5.3 and v6.0 will automatically migrate (through schema evolution) upon registering in ROMeo Real-Time System 6.0.1. Please contact your SIMSCI representative for a migration path of ROMeo\ARPM systems prior to 5.0. Note: Starting with ROMeo 5.0, migrating model application databases requires the user to perform Save As after migration to update the database with imbedded thermo content that is required for future upgrade migration. Failing to perform Save As after schema migration will generate errors in subsequent upgrade of the database.

Release Notes for ROMeo 6.0.1

Summary of Defects Fixed in 6.0.1


Defects fixed since 6.0 release

General Flowsheet
Controller CV disconnected (LFRM#15751) If the controller CV is not connected and the user tries to solve the flowsheet, the ensuing exception is handled with a descriptive error message FeedCompositionEstimator error (LFRM#15839) A freshly configured FCE on a source will not give a DOF error in a fresh Flowsheet Fix Free Status of Splitter inside a SUBFS (LFRM#15893) The fix/free status of a splitter streams is not reverted once the subflowsheet containing splitter is turned off and back on if the splitter product streams are across the subflowsheet boundary. Measurement Standard Deviation wrongly calculated (LFRM#15847) The measurement unit does not recalculate/update the standard deviation when the measurement accuracy (eabs1, eabs2, erel, ref value, full scale value, etc) is changed in the reconciliation data tab Error Messages on Trayed column (LFRM#15878) Error messages appear in the diagnostics window when a new mapped section is added to the top of a column trayed section. Copy/Paste of Unit copies macros as well (LFRM#15869) Copy/Paste a unit from one subflowsheet to another will not carry the macros as well (overwrite). Custom reports (views) cascade issue (LFRM#15736) Custom reports made of just views cascade down into sub-flowsheets. Custom reports that also contain information on named blocks do not cascade down

Release Notes for ROMeo 6.0.1

RTS/EDI
RTS Scheduling (LFRM#15729) When a real time sequence that is scheduled to run once per month is taken offline and placed back online, it will not run immediately. RTS OPP Task (LFRM#15816) OPP does not overwrite MVC2 bounds in the Implementation submodel if they are blank in the main Target model EDI OPC DS Array tag failure (LFRM#15774) Import on OPC port groups/blocks will not fails with array tags of names longer than 21 characters and there are more than 8 tags. PI-OPC DS invalid tag data import (LFRM#15845) Improved handling for PI-OPC Datasource when the portgroups with some invalid tags. SQL OLEDB EDI login option changes during migration (LFRM#15852) Schema evolved OLEDB datasources will have the Default SQL authentication selected instead of Windows. This corrects the wrong schema evolve code in 5.3.1 and 6.0 (where the authentication was set to Windows). OPC H.D.A Import on Windows 7 (LFRM#15884) ROMeo crash is fixed when the user performs HDA import on OPC port groups/blocks on Windows7 OS machine. ODBC Block Import with missing data caused Crash (LFRM#15912) ODBC EDI-Block Import Data containing some ports with missing data does not cause a ROMeo crash with CORBA exception. PI OPC H.D.A. Import % confidence issue (LFRM#15925) User given % confidence (non-zero) is used in deciding if the imported aggregate value is Good or Bad.

Solve/Sensitivity Analysis
Solver Presenter (LFRM#15728) Solver presenter works for parameterization mode. It used to fail with an error message about missing files.

OPS Addin
Accessing single variable collection in OPS Addin (LFRM#15888)

Release Notes for ROMeo 6.0.1

OPS Addin can see variables in a ROMeo collection containing one item

TCL Macros / Macro Documentation


Get/SetEDIParameter macro error (LFRM#15920) Get/SetEDIParameter macro will display an error message when a parameter is not recognized GetGainVariableName macro syntax (LFRM#15890) Macro call GetGainVariableName was incorrect and documentation has been updated.

Release Notes for ROMeo 6.0.1

Summary of Open Defects and Known Issues in ROMeo 6.0.1


The following are open defects reported since 5.2.2, 5.3.1, 6.0 Please check the Simsci-Esscor website at known defects in Version 6.0.1.
WWW.SIMSCI-ESSCOR.COM

for a summary of

Install/Migration
5.2 TDM COEX (LFRM#14809) Installing ROMeo 5.2 or ARPM 5.2 on top of ROMeo 6.0.1 will result in the Help about build date on TDM to changed from Jan-02-2010 to Aug-06-2009 (one from 5.2) The TDM version files are still the later version and will work with for ROMeo/ARPM 5.2 and ROMeo 6.0.1 5.3 Client Install (LFRM#14854) Client only install will generate pop-up "Client Product has been Swapped, Please Select Server Product Accordingly" at end of install Click OK and the installation will continue

General Flowsheet
Resized Column size reset (LFRM#15902) Resized Column is reset to default size on exiting subflowsheet or incremental regenerate Work around: Resize the column at the very beginning of the design phase at the column subflowsheet level. (Note that the column cannot then be sized with respect to other units on the flowsheet as they do not appear on the column subflowsheet). Splitter Flow Specification (LFRM#15915) Splitter Flow Specification reverts to Molar if a fraction is specified Splitter Stream On/OFF color change (LFRM#15958) Changing the On Off status of a splitter product stream using the toggle button on a splitter GUI will not change the color of the stream that has been turned on/off.

Material Balance Module


Excel MBM Report Issue (LFRM#15901) An Excel MBM Report (Sim mode in this case) cannot be opened if it contains tags that are named xxDxxx (where x represents a numeric value). Work around: Change the capital xxDxxx to small case xxdxxx

Release Notes for ROMeo 6.0.1

10

Solver/Sensitivity Analysis
5.2.1 Post Solution Analysis Trace File problem (LFRM#15414) The Post Solution Analysis trace file is showing wrong do/dx for tier streams. The derivatives are correct for sensitivity analysis runs and reports but wrong for the solver trace file. 5.3 Multiple Sensitivity Analysis (LFRM#14678) Multiple Sensitivity Analysis execution may cause memory increase for processes MA_Server.exe and Solver.exe Sensitivity Analysis Collection Solve (LFRM#15790) Sensitivity Analysis gives different solutions between an FS solve and a collection solve

RTS
RTS DRR Data Reconciliation Objective Scaling (LFRM#15914) In the Data Rec Review in RTS, it checks against the scaled DR objective, rather than looking at the unscaled value

Portal / OPS ADDin


Portal2.1.1 File open (LFRM#15909) Portal 2.1.1 will not open files with Belgial Local Settings Work around: Changing the regional settings to English (United States) works fine Some ROMeo variables drag drop issue in Portal (LFRM#15830) Some variables in ROMeo throw an error when being dragged into Portal. (ROMeo UA term available in ROMeo 2-sided HXs and HW linker throws an error when being dragged into Portal) UOM Set return value in OPSADDin (LFRM#15928) Choosing UOM set "Current" returns value in internal units instead of the current UOM set for OPSAddin

Release Notes for ROMeo 6.0.1

11

License and Copyright Information


ROMeo 6.0.1 Release Notes
The software described in this guide is furnished under a written agreement and may be used only in accordance with the terms and conditions of the license agreement under which you obtained it. Invensys Systems, Inc. reserves the right to make changes without prior notice.

Copyright Notice
2010 Invensys Systems, Inc. All Rights Reserved. No part of this publication may be copied and/or distributed without the express written permission of Invensys Systems, Inc., Lake Forest, CA.

Trademarks
ROMeo and ARPM are trademarks of Invensys Inc. SimSci-Esscor are a registered mark of Invensys. Windows 2008 Server, Windows 7, Windows XP, Windows 2003, Windows NT, and MS-DOS are registered marks and/or trademarks of Microsoft Corporation. Pentium is a registered trademark of Intel Corporation. FLEXlm is a trademark of Flexera Corporation. ObjectStore is a trademark of Progress Software, Inc. All other products are trademarks or registered trademarks of their respective companies. Printed in the United States of America, March 2012.

Release Notes for ROMeo 6.0.1

12

Potrebbero piacerti anche