Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Addendum No.: Date: Manuals Affected: C1577M-A August 4, 2004 CM9760 Series Manuals C538M, C539M-A, C540M-B, C541M-C, C542M-B, C543M-A, C544M, C549M-A, C572M, C573M-D, C578M, C579M, C1501M, C1503M, C1510M-QS, C1510M-A, C1520M-B, C1528M-C, C1940M, C1941M, C1942M, and C1943M The CM9760-CC1 has been replaced with the CM9700-CC1 and the CM9760-MGR management software has been replaced with the CM9700-MGR management software. Keep the following in mind when referring to the instructions contained in these manuals: The CM9700-CC1 contains the latest CC1 software (version 9.01 or higher), and is programmed with the new CM9700-MGR management software. Despite the difference in model numbers, the CM9700-CC1 functions the same as the CM9760-CC1 and most of the information in these manuals applies to version 9.01 (or higher) CPU. You can add the CM9700-CC1 to an existing CM9760 system if you upgrade the existing CM9760-CC1 units with the current software (version level 9.01 or higher). Software version 9.01 requires a minimum of 16 MB of RAM in the CPU. If required, you can upgrade the RAM in older CM9760-CC1 units using the software upgrade kit appropriate for your CPU. Do not use the CM9760-MGR instructions contained in these manuals. Refer to the CM9700-MGR Getting Started Software Guide, on-screen help, or Online Help for instructions.
Manual Update:
Pelco World Headquarters 3500 Pelco Way, Clovis, California 93612-5699 USA www.pelco.com USA & Canada: Tel: 800/289-9100 Fax: 800/289-9150 International: Tel: 1-559/292-1981 Fax: 1-559/348-1120
C1940M (7/98)
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
CONTENTS
Section Page
1.0 GENERAL .................................................................................................. 3 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 3 1.2 REGULATORY NOTICES .................................................................. 4 2.0 DESCRIPTION .......................................................................................... 5 2.1 MODELS ............................................................................................ 5 2.2 FEATURES ........................................................................................ 5 2.3 CERTIFICATIONS ............................................................................. 5 3.0 PRE-INSTALLATION INFORMATION ........................................................ 6 3.1 FRONT VIEW ..................................................................................... 6 3.2 REAR VIEW ....................................................................................... 6 4.0 INSTALLATION .......................................................................................... 8 5.0 OPERATION ............................................................................................. 10 6.0 SPECIFICATIONS .................................................................................... 11 7.0 WARRANTY AND RETURN INFORMATION ........................................... 12
LIST OF ILLUSTRATIONS
Figure 1 2 3 4 5 Page CM9760-CDU-T, Front View ............................................................... 6 CM9760-CDU-T, Rear View ............................................................... 6 CM9760-CDU-T, Rear View Connector Details ................................. 7 CM9760-CDU-T, Daisy-Chain Configuration ..................................... 8 CM9760-CDU, System Hook-Up-Block Diagram ............................... 9
REVISION HISTORY
Manual # C1940M Date 7/98 Comments Original version.
1.0 GENERAL
1.1 IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed. 1. 2. Installation and servicing should only be done by qualified service personnel and conform to all local codes. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for Indoor use only and it must not be installed where exposed to rain and moisture. Only use replacement parts recommended by Pelco. After replacement/repair of this units electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
3. 4.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USERSERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
2.0 DESCRIPTION
The CM9760-CDU-T code distribution unit is a 16-channel RS-422 transmit only (2-wire and ground) distributor. It was designed as an accessory of the System 9760, but can be used with any system that uses RS-422 serial communications. The CDU will primarily be used to install pan/tilt and dome receivers in a star configuration.
2.1 MODELS
CM9760-CDU-T 16-channel RS-422 transmit only distributor
2.2 FEATURES
The CM9760-CDU has the following features: Two 8-position, RJ-45 connectors in parallel, providing an input from a controller and an output for an additional daisy-chained CDU box Sixteen 3-position screw terminal connectors used to output 16 RS-422 transmit only code lines Two-pin terminal connector (refer to figure 3) for an external 10 to 24 VAC/VDC power source Standard 100-240 VAC 50/60Hz line input (auto-ranging)
2.3 CERTIFICATIONS
The product identified below has been tested and certified for agency compliance as noted. Agency Compliance Certification Model CM9700-CDU-T CE X FCC X UL CSA/cUL
Applicable CE, FCC, UL, and CSA/cUL directives/standards: 93/68/EECCE Mark Directive 89/336/EEC, 92/31/EECElectromagnetic Compatibility (EMC) Directives EN 55022: 1984 Class BRadio-frequency emissions limits EN 50082-2: 1992Immunity standard IEC 801-2: 1984ESD immunity IEC 801-3: 1984Radiated field immunity IEC 801-4: 1988Electrical transients FCC47 CFR, Part 15, Subpart B, Class B
O E
Figure 3 further details the mating plugs, pin-outs, and so on pictured in Figure 2. Note that for externally supplied power sources, the DC supply hook-up can handle forward or reverse hook-up of the input source. The internal bridge can handle either polarity. There are, naturally, no polarity concerns with an externally supplied AC power source.
4.0 INSTALLATION
Installation of the unit is straightforward. The unit is rack/wall mountable and is only 6" deep (15.24 cm). In addition to the 16 lines available for output with one unit, eight CDUs may be daisy-chained together. This will allow 128 receivers (that support 128 address settings) to be connected on a single Sercom port. Figure 4 illustrates two units daisy-chained providing 32 independent drive lines.
Pictured in Figure 5 is a very simplified block diagram of the system hook-up of a CM9760-CDU from the viewpoint of its transmit capabilities only. The illustration details pin-outs and other hook-up details.
5.0 OPERATION
The CM9760-CDU-T unit works as a distribution repeater for expanding one RS422 communication port into 16 isolated and buffered RS-422 ports. The primary use for the CDU-T is to provide quick, easy, and proper data-line distribution for serial type pan/tilt and dome receivers. In the case of these isolated RS-422 drive lines, the remote devices may be located as far as 4,000 feet (1,219 m) away from the controller, depending on the physical parameters of the connection. The unit is ideal for use on larger switching systems where it becomes desirable to home-run the RS-422 data lines for controlling pan/tilt or dome receivers.
10
6.0 SPECIFICATIONS
NOTE: If external AC transformer is used, it must be capable of supplying at least 8 watts. DC source can be hooked up without regard to polarity.
ELECTRICAL Input Voltage: 100-240 VAC, 50/60 Hz, auto-ranging, or Independent external source, 10-24 VAC/VDC
Power Consumption: Data Ports Input: Output: Drive Lines: Fusing: Indicators:
30 vA
One RS-422, RJ-45 female connector One RS-422, RJ-45 female connector Sixteen 3-position screw-terminals with mating plugs 500 mA, 250 V 1 power LED, green 1 data LED, red
MECHANICAL Dimensions: Operating Temperature: Weight: GENERAL Mechanical Connectors Power: 19" W x 1.75" H x 6" D (48.26 cm x 4.45 cm x 15.24 cm)
AC power cord input, 3-wire, #18 AWG 2-pin screw terminal with mating plug for external power source Two RJ-45, female
Sixteen 3-pin headers with mating plug; connectors can accept 1428 AWG
11
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge. Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below. If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to: Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699 If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following: If the goods are to be sent by a COURIER SERVICE, send the goods to: Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA If the goods are to be sent by a FREIGHT FORWARDER, send the goods to: Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. Copyright 1998, Pelco. All rights reserved.
12