Installation Guide For HBA Models SG-XPCIE1FCQF8-Z, SG-PCIE1FC-QF8-Z, SG-XPCIE1FCQF8-N, SG-PCIE1FC-QF8-N and SG-XPCIE2-QF8-Z, SG-PCIE2FC-QF8-Z, SGXPCIE2-QF8-N, SG-PCIE2FC-QF8-N
Copyright 2008, 2009, 2011, Oracle and/or its afliates. All rights reserved. This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited. The information contained herein is subject to change without notice and is not warranted to be error-free. If you nd any errors, please report them to us in writing. If this is software or related software documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, the following notice is applicable: U.S. GOVERNMENT RIGHTS. Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers are "commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and agency-specic supplemental regulations. As such, the use, duplication, disclosure, modication, and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR 52.227-19, Commercial Computer Software License (December 2007). Oracle America, Inc., 500 Oracle Parkway, Redwood City, CA 94065. This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for use in any inherently dangerous applications, including applications which may create a risk of personal injury. If you use this software or hardware in dangerous applications, then you shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure its safe use. Oracle Corporation and its afliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications. Oracle and Java are registered trademarks of Oracle and/or its afliates. Other names may be trademarks of their respective owners. AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. UNIX is a registered trademark licensed through X/Open Company, Ltd. This software or hardware and documentation may provide access to or information on content, products, and services from third parties. Oracle Corporation and its afliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and services. Oracle Corporation and its afliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content, products, or services. Copyright 2008, 2009, 2011, Oracle et/ou ses aflis. Tous droits rservs. Ce logiciel et la documentation qui laccompagne sont protgs par les lois sur la proprit intellectuelle. Ils sont concds sous licence et soumis des restrictions dutilisation et de divulgation. Sauf disposition de votre contrat de licence ou de la loi, vous ne pouvez pas copier, reproduire, traduire, diffuser, modier, breveter, transmettre, distribuer, exposer, excuter, publier ou afcher le logiciel, mme partiellement, sous quelque forme et par quelque procd que ce soit. Par ailleurs, il est interdit de procder toute ingnierie inverse du logiciel, de le dsassembler ou de le dcompiler, except des ns dinteroprabilit avec des logiciels tiers ou tel que prescrit par la loi. Les informations fournies dans ce document sont susceptibles de modication sans pravis. Par ailleurs, Oracle Corporation ne garantit pas quelles soient exemptes derreurs et vous invite, le cas chant, lui en faire part par crit. Si ce logiciel, ou la documentation qui laccompagne, est concd sous licence au Gouvernement des Etats-Unis, ou toute entit qui dlivre la licence de ce logiciel ou lutilise pour le compte du Gouvernement des Etats-Unis, la notice suivante sapplique : U.S. GOVERNMENT RIGHTS. Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers are "commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and agency-specic supplemental regulations. As such, the use, duplication, disclosure, modication, and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR 52.227-19, Commercial Computer Software License (December 2007). Oracle America, Inc., 500 Oracle Parkway, Redwood City, CA 94065. Ce logiciel ou matriel a t dvelopp pour un usage gnral dans le cadre dapplications de gestion des informations. Ce logiciel ou matriel nest pas conu ni nest destin tre utilis dans des applications risque, notamment dans des applications pouvant causer des dommages corporels. Si vous utilisez ce logiciel ou matriel dans le cadre dapplications dangereuses, il est de votre responsabilit de prendre toutes les mesures de secours, de sauvegarde, de redondance et autres mesures ncessaires son utilisation dans des conditions optimales de scurit. Oracle Corporation et ses aflis dclinent toute responsabilit quant aux dommages causs par lutilisation de ce logiciel ou matriel pour ce type dapplications. Oracle et Java sont des marques dposes dOracle Corporation et/ou de ses aflis.Tout autre nom mentionn peut correspondre des marques appartenant dautres propritaires quOracle. AMD, Opteron, le logo AMD et le logo AMD Opteron sont des marques ou des marques dposes dAdvanced Micro Devices. Intel et Intel Xeon sont des marques ou des marques dposes dIntel Corporation. Toutes les marques SPARC sont utilises sous licence et sont des marques ou des marques dposes de SPARC International, Inc. UNIX est une marque dpose concde sous licence par X/Open Company, Ltd. Ce logiciel ou matriel et la documentation qui laccompagne peuvent fournir des informations ou des liens donnant accs des contenus, des produits et des services manant de tiers. Oracle Corporation et ses aflis dclinent toute responsabilit ou garantie expresse quant aux contenus, produits ou services manant de tiers. En aucun cas, Oracle Corporation et ses aflis ne sauraient tre tenus pour responsables des pertes subies, des cots occasionns ou des dommages causs par laccs des contenus, produits ou services tiers, ou leur utilisation.
Contents
vii
2 4
Environmental Requirements 2.
11 11
iii
12 13
To Verify Proper Installation (Oracle SPARC Systems) To Verify Attached Storage (Oracle SPARC Systems)
16 19 20
24 24
3.
Software Installation
Installing Software for the Oracle Solaris OS Installing the Fibre Channel Driver
25
25 26
Installing Software for the Red Hat/SUSE Linux OS Downloading the Red Hat/SUSE Linux Drivers
29
31
Installing Software for the VMware Technology Installing Software for the Windows OS
31 32
To Download the Fibre Channel Driver To Install the Fibre Channel Driver 32 33
iv
33
Installing a CLI for Updating the BIOS and FCode 4. Known Issues 35 35
37
Contents
vi
UNIX Commands on page vii Documentation, Support, and Training on page viii
UNIX Commands
This document might not contain information about basic UNIX commands and procedures such as shutting down the system, booting the system, and configuring devices. Refer to the following for this information:
Software documentation that you received with your system Oracle Solaris Operating System documentation, which is at: http://www.oracle.com/technetwork/documentation/solaris-10192992.html
vii
viii
CHAPTER
HBA Overview
This chapter provides a basic overview of Oracles single and dual port StorageTek 8 Gb FC PCI-Express host bus adapter (HBA), which uses QLogic technology. This chapter also describes the various operating systems, host platforms, storage, and infrastructure configurations that support the HBA and lists the HBA environmental requirements. This chapter contains the following topics:
Kit Contents on page 1 HBA Features and Specifications on page 2 Operating System and Technology Requirements on page 4 System Interoperability on page 5 Environmental Requirements on page 9
Kit Contents
Adherance to the PCI Express Card Electromechanical Specification Solaris Dynamic Reconfiguration support Fibre Channel boot for all supported operating systems SunVTS diagnostics support
FC-SW switched fabric (N_Port) FC-AL arbitrated loop (NL_Port) Point-to-point (N_Port)
Removable SFP shortwave optics for attachment to multi-mode fiber with LCstyle connectors Compatibility with:
Fibre Channel Physical and Signaling (FC-PH, FC-PH-2, FC-PH-3) Fibre Channel Framing and Signaling (FC-FS) Fibre Channel Physical Interface (FC-PI) Fibre Channel Generic Services (FC-GS-3) Fibre Channel Tape and Medium Changers (FC-Tape) Fibre Channel Protocol for SCSI (FC-FCP)
PCIe connector PCIe signaling environment PCIe transfer rates (maximum) Number of FC ports FC bus type (external) FC transfer rate FC topologies Nonvolatile memory
x8 PCI-Express x8 (8 active lanes) PCI-Express Gen 1 x8 at 2.5 Gbps PCI-Express Gen 2 x4 at 5 Gbps One (single port) or two (dual port) Fiber-optic media, short-wave, multimode fiber (400-M5- SN-S) 800 MBps per port maximum, half-duplex 1600 MBps per port maximum, full-duplex FC-SW switched fabric (N-Port), FC-AL arbitrated loop (NL-Port), and point-to-point (N-Port) Type: Flash (SPI) Size (total for all ports): 2 MB Purpose: Firmware, Universal Boot Code, POST Store persistent data, such as driver trace info Store HBA parameters Store VPD data Non-volatile error log to reduce number of no defect found returned adapters. Error log can wrap around. Software should be able to read this error-log (IBM request Section 1.6.2) Two small form-factor pluggable (SFP) multimode optics with LC-style connectors Limited: 2Gb 4Gb 8Gb Linear: 2Gb 4Gb 8Gb 2Gb 4Gb 8Gb OM1 150m OM1 70m OM1 21m OM1 n/a OM1 n/a OM1 40m 10KM 10KM 10KM OM2 300m OM2 150m OM2 50m OM2 n/a OM2 n/a OM2 100m OM3 500m OM3 380m OM3 150m OM3 n/a OM3 n/a OM3 300m
Chapter 1
HBA Overview
Three LEDs per FC channel (yellow, green, amber) on front panel as status indicators SG-XPCIE1FC-QF8-Z (single port): 7.3 watts SG-XPCIE2FC-QF8-Z(dual port): 9.7 watts Low profile MD2, PCI-Express HBA
Operating System/Technology
Oracle Solaris 10 OS for the x86 (32-bit and 64-bit) platforms Oracle Solaris 10 OS for the SPARC (32-bit and 64bit) platforms Linux OS
Oracle Solaris 10 8/07 (s10u4) with patch 125165 Oracle Solaris 10 5/08 (s10u5) Oracle Solaris 10 8/07 (s10u4) with patch 125166 Oracle Solaris 10 5/08 (s10u5) Red Hat Enterprise Linux 4 (32-bit and 64-bit), U6 Red Hat Enterprise Linux 5 (32-bit and 64-bit), U1 SUSE Linux Enterprise Server 9 (32-bit and 64-bit), SP4 SUSE Linux Enterprise Server 10 (32-bit and 64-bit), SP1 Windows Windows Windows Windows Windows Server Server Server Server Server 2003 2003 2003 2003 2008 SP1 (32-bit and 64-bit), x64 SP2 (32-bit and 64-bit), x64 SP1/R2 (32-bit and 64-bit), x64 SP2/R2 (32-bit and 64-bit), x64 (32-bit and 64-bit)
VMware technology
System Interoperability
This section provides information about selected platforms, storage systems, switches, and software that are compatible with the heterogeneous FC network design of the HBA. This section contains the following topics:
Host Platform Support on page 5 Storage Support on page 6 Switch and Director Support on page 7 Software Support on page 8
Oracle SPARC Servers Sun SPARC Enterprise T2000 Sun SPARC Enterprise T5120 Sun SPARC Enterprise T5140 Sun SPARC Enterprise T5220 Sun SPARC Enterprise T5240 Sun SPARC Enterprise T5440 Sun Fire V245 Sun Fire V445 Sun SPARC Enterprise M4000 Sun SPARC Enterprise M5000 Sun SPARC Enterprise M8000 Sun SPARC Enterprise M9000-32 Sun SPARC Enterprise M9000-64 Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris
Chapter 1
HBA Overview
Oracle x64/x86 (AMD) Systems Sun Fire X2100 M2 Sun Fire X2200 M2 Sun Fire X4100 M2 Sun Fire X4140 Sun Fire X4200 M2 Sun Fire X4240 Sun Fire X4440 Sun Fire X4600 Sun Fire X4600 M2 Oracle x64/x86 (Intel) Systems Sun Fire X4150 Sun Fire X4250 Sun Fire X4450 Sun Fire X4540 Oracle Solaris, Linux, Windows Oracle Solaris, Linux, Windows Oracle Solaris, Linux, Windows Oracle Solaris, Linux, Windows Oracle Solaris, Linux, Windows, VMware Oracle Solaris, Linux, Windows, VMware Oracle Solaris, Linux, Windows, VMware Oracle Solaris, Linux, Windows, VMware Oracle Solaris, Linux, Windows, VMware Oracle Solaris, Linux, Windows, VMware Oracle Solaris, Linux, Windows, VMware Oracle Solaris, Linux, Windows, VMware Oracle Solaris, Linux, Windows, VMware
Storage Support
This section lists the arrays, storage systems, chassis, and tape storage devices supported by the HBA. This section provides the following topics:
Sun StorageTek 2540 array Sun StorageTek 6140 array Sun StorageTek 6540 array Sun StorageTek 9970 system Sun StorageTek 9980/9985 system
Sun StorageTek SL24 tape autoloader Sun StorageTek SL48 tape library Sun StorageTek SL500 modular library Sun StorageTek L1400 tape library Sun StorageTek SL3000 tape library Sun StorageTek SL8500 modular library Sun StorageTek Virtual Tape Library (VTL): VTL Value and VTL Plus Sun StorageTek T10000A and T10000B tape drives Sun StorageTek T9840C tape drive Sun StorageTek T9840D tape drive Sun StorageTek T9940B tape drive
IBM and HP LTO3 tape drives IBM and HP LTO4 tape drives Quantum DLT-S4 tape drive
Brocade DCX backbone switch Brocade 200E switch Brocade 300 switch Brocade 4100 switch Brocade 4900 switch Brocade 5000 switch Brocade 5100 switch Brocade 5300 switch Brocade 7500 switch Brocade Mi10K director Brocade M6140 director
Chapter 1 HBA Overview 7
Cisco MDS 9124 24-port multilayer fabric switch Cisco MDS 9134 multilayer fabric switch Cisco MDS 9222i multiservice modular switch Cisco MDS 9509 multilayer director Cisco MDS 9513 multilayer director QLogic SANbox 5600 switch QLogic SANbox 5602 switch QLogic SANbox 5802v switch QLogic SANbox 9000 stackable chassis FC switch series Oracle Storage Fibre Channel Switch 5802
Software Support
The HBA supports the software applications listed in TABLE 1-4.
TABLE 1-4
Sun Cluster 3.x Sun StorEdge Enterprise Backup Software 7.2/7.3/7.4 Sun StorageTek Availability Suite 3.0/4.0 Sun StorageTek Performance Suite 3.0/4.0 Sun StorageTek Utilization Suite 3.0/4.0 Veritas NetBackup 5.1, 6.x Veritas Storage Foundation 4.1/5.0 Support for native multi-pathing
Oracle Solaris Oracle Solaris, Linux, and Windows Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris Oracle Solaris
Environmental Requirements
TABLE 1-5 lists the HBA minimum environmental requirements.
TABLE 1-5 Specification
0 to 40C, noncondensing
10% to 90% RH, noncondensing, 27C max wet 93% RH, noncondensing, 38C max wet bulb bulb 3000m 0.20G in all axes, 5500 Hz sine Operating: 5G, 11 ms half-sine 12,000m 1.0G in all axes, 5500 Hz sine 30G 11 ms half-sine
Chapter 1
HBA Overview
10
CHAPTER
Observing ESD and Handling Precautions on page 11 Installing the Hardware on page 12 Testing the Installation on page 16 Replacing the SFP+ Unit on the HBA on page 23 Removing the Hardware on page 24
Leave the HBA in its antistatic bag until you are ready to install it in the system.
Always use a properly fitted and grounded wrist strap or other suitable ESD protection when handling the HBA and observe proper ESD grounding
techniques.
Hold the HBA by the edge of the PCB, not the connectors.
11
Place the HBA on a properly grounded antistatic work surface pad when it is out of its protective antistatic bag.
To Install the HBA on page 12 To Connect the Optical Cable on page 14 To Apply Power on page 15
Note The HBA comes with a low-profile PCI bracket installed. This bracket is
approximately 3.11 in. (7.9 cm) long. A standard mounting bracket, which is approximately 4.75 in. (12.6 cm), is provided with each X-option order. a. Remove the SFP(s), if installed. b. Remove the mounting bracket screws from the HBA (see FIGURE 2-1).
12
FIGURE 2-1
c. Remove the bracket and store it for future use. d. Align the new mounting bracket tabs with the holes in the HBA.
Note Be careful not to push the bracket past the grounding tabs of the transceiver
housing. Ensure that the LEDs are properly aligned with the holes in the bracket. e. Replace the screws that attach the HBA to the bracket. f. Reinstall the SFP(s), if removed in Step a. 7. Insert the HBA into the empty PCI-Express 8-lane slot. 8. Press firmly until the HBA is seated. 9. Secure the mounting bracket of the HBA to the case with the panel screw or clip. 10. Replace the system case and tighten the case screws. The HBA is now installed and you can connect the optical cables.
Chapter 2
13
14
FIGURE 2-3
2. Connect the other end of the cable to the FC device. After the optical cable is connected to the HBA, you can power on the system, if required. See your system installationg and service manual for more information.
To Apply Power
1. Verify that the HBA is securely installed in the system. 2. Verify that the correct fiber-optic cable is attached. 3. Refer to your system installation or service manual to determine how to power on the system.
Chapter 2
15
4. Observe the light-emitting diode (LED) status for the power-on self test (POST) results as shown in TABLE 2-1. The yellow, green, and amber LEDs can be seen through openings in the mounting bracket of the HBA. TABLE 2-1 summarizes the LED status conditions.
TABLE 2-1 Yellow LED
LED Status
Green LED Amber LED State
Off On Flash Flash in sequence* Off Off On (for link up) or Flash (if I/O activity) Flash
Off On Flash Flash in sequence* Off On (for link up) or Flash (if I/O activity) Off Off
Off On Flash Flash in sequence* On (for link up) or Flash (if I/O activity) Off Off Flash
Power off Power on (before firmware initialization) Power on (after firmware initialization) Firmware fault 2 Gbps link UP/ACT 4 Gbps link UP/ACT 8 Gbps link UP/ACT Beacon
* Flash sequence is yellow LED > green LED > amber LED, then back to yellow LED.
To Verify Proper Installation (Oracle SPARC) on page 16 To Verify Attached Storage (Oracle SPARC) on page 19
16
{0} ok show-devs /ebus@c0 /pci-performance-counters@0 /pci@0 /niu@80 /cpu@e /cpu@d /cpu@c /cpu@b /cpu@a /cpu@9 /cpu@8 /cpu@7 /cpu@6 /cpu@5 /cpu@4 /cpu@3 /cpu@2 /cpu@1 /cpu@0 /virtual-devices@100 /virtual-memory /memory@m0,8000000 /aliases /options /openprom /chosen /packages /ebus@c0/serial@0,ca0000 /pci@0/pci@0 /pci@0/pci@0/pci@9 /pci@0/pci@0/pci@8 /pci@0/pci@0/pci@2 /pci@0/pci@0/pci@1 /pci@0/pci@0/pci@8/pci@0 /pci@0/pci@0/pci@8/pci@0/pci@a /pci@0/pci@0/pci@8/pci@0/pci@9 /pci@0/pci@0/pci@8/pci@0/pci@8 /pci@0/pci@0/pci@8/pci@0/pci@2 /pci@0/pci@0/pci@8/pci@0/pci@1 /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0,1 /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0 /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0,1/fp@0,0 /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0,1/fp@0,0/disk /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0/fp@0,0 /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0/fp@0,0/disk /pci@0/pci@0/pci@2/scsi@0
Chapter 2
17
/pci@0/pci@0/pci@2/scsi@0/disk /pci@0/pci@0/pci@2/scsi@0/tape /pci@0/pci@0/pci@1/pci@0 /pci@0/pci@0/pci@1/pci@0/pci@3 /pci@0/pci@0/pci@1/pci@0/pci@2 /pci@0/pci@0/pci@1/pci@0/pci@1 /pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1 /pci@0/pci@0/pci@1/pci@0/pci@3/network@0 /pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1 /pci@0/pci@0/pci@1/pci@0/pci@2/network@0 /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0 /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2 /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,1 /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0 /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/hub@4 /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2 /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2/disk /virtual-devices@100/rtc@5 /virtual-devices@100/console@1 /virtual-devices@100/random-number-generator@e /virtual-devices@100/ncp@6 /virtual-devices@100/n2cp@7 /virtual-devices@100/channel-devices@200 /virtual-devices@100/flashprom@0 /virtual-devices@100/channel-devices@200/virtual-channel-client@1 /virtual-devices@100/channel-devices@200/virtual-channel@0 /virtual-devices@100/channel-devices@200/virtual-channel-client@2 /virtual-devices@100/channel-devices@200/virtual-channel@3 /openprom/client-services /packages/obp-tftp /packages/kbd-translator /packages/SUNW,asr /packages/dropins /packages/terminal-emulator /packages/disk-label /packages/deblocker /packages/SUNW,builtin-drivers
2. To identify the port as a StorageTek 8 Gb FC port, use the cd command to change to the SUNW,qlc@n directories, and use the .properties command, as shown in the following example:
cd /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0
In the next example, the .properties command output displays the properties of one port in a dual port HBA.
18
{1} ok select /pci@1e,600000/pci@0/pci@2/SUNW,qlc@0 QLogic QLE2562 Host Adapter FCode(SPARC): 2.03b1 06/06/08 Firmware version 4.03.02 {1} ok .properties assigned-addresses 81060010 00000000 00002000 00000000 00000100 82060014 00000000 04000000 00000000 00004000 82060030 00000000 04040000 00000000 00040000 manufacturer QLGC version QLE2562 Host Adapter FCode(SPARC): 2.03 06/30/08 model QLE2562 node-wwn 20 00 00 1b 32 14 40 66 port-wwn 21 00 00 1b 32 14 40 66 reg 00060000 00000000 00000000 00000000 00000000 01060010 00000000 00000000 00000000 00000100 03060014 00000000 00000000 00000000 00001000 compatible pciex1077,2532.1077.171.2 pciex1077,2532.1077.171 pciex1077,171 pciex1077,2532.2 pciex1077,2532 pciclass,c0400 short-version 2.03 06/30/08 devsel-speed 00000000 max-latency 00000000 min-grant 00000000 #size-cells 00000000 #address-cells 00000002 device_type scsi-fcp name SUNW,qlc fcode-rom-offset 0000b200 interrupts 00000001 class-code 000c0400 subsystem-id 00000171 subsystem-vendor-id 00001077 revision-id 00000002 device-id 00002532 vendor-id 00001077 {1}
If online storage is connected to the HBA, use the apply show-children command to list the attached storage.
Chapter 2
19
Note You might need to run the reset-all command before using the apply
show-children command. In the example that follows, a storage JBOD has one target and two LUNs attached to one port of a dual port HBA.
{0} ok show-disks a) /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0,1/fp@0,0/disk b) /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0/fp@0,0/disk c) /pci@0/pci@0/pci@2/scsi@0/disk d) /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2/disk q) NO SELECTION Enter Selection, q to quit: b {0} ok select /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0 QLogic QLE2562 Host Adapter FCode(SPARC): 2.03 06/30/08 Firmware version 4.03.02 {0} ok show-children Adapter portID - 11000 ************** Fabric Attached Devices ************** Dev# 0(0) PortID 100e8 Port WWN 21000011c68115b3 LUN 0(0) DISK SEAGATE ST336854FC 0005 Dev# 1(1) PortID 10100 LUN a(10) DISK STK LUN b(11) DISK STK {0} ok Port WWN 201500a0b84718a4 FLEXLINE 380 0619 FLEXLINE 380 0619
QLogic Corporation QLE2562 PCI Fibre Channel ROM BIOS version 2.02 Copyright (c) QLogic Corporation 1992-2008. All rights reserved. www.qlogic.com Press <Ctrl-Q> or <Alt-Q> for Fast!UTIL BIOS for Adapter 0 is disabled BIOS for Adapter 1 is disabled ROM BIOS NOT INSTALLED
20
QLogic Corporation QLE2562 PCI Fibre Channel ROM BIOS version 2.02 Copyright (c) QLogic Corporation 1993-2008. All rights reserved. www.qlogic.com Press <Ctrl-Q> or <Alt-Q> for Fast!UTIL BIOS for Adapter 0 is disabled BIOS for Adapter 1 is disabled ROM BIOS NOT INSTALLED <CTRL-Q> Detected, Initialization in progress, Please wait...
QLogic Fast!UTIL Select Host Adapter ---------------------------------------------------------Adapter Type I/O Address Slot Bus Device Function QLE2562 QLE2562 9400 9800 01 01 02 02 01 01 1 0
3. Use the Arrow key to highlight the HBA port that has connected devices and press Enter. The following QLogic Fast!UTIL menu is displayed.
Chapter 2
21
QLogic Fast!UTIL Selected Adapter ---------------------------------------------------------Adapter Type I/O Address Slot Bus Device Function QLE2562 9400 01 02 01 1
---------------------------------------------------------Fast!UTIL Options Configuration Settings Scan Fibre Devices Fibre Disk Utility Loopback Data Test Select Host Adapter Exit Fast!UTIL
4. Use the Arrow key to highlight Scan Fibre Devices and press Enter. In the example that follows, a storage JBOD has six targets attached to one port of a dual port HBA. The following QLogic Fast!UTIL menu is displayed.
QLogic Fast!UTIL Scan Fibre Channel Loop ID 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Vendor Product Rev 0205 0205 0205 0205 0205 0205 D1046 Port Name 21000004CF64C8E0 21000004CF6493D0 21000004CF6428C4 21000004CF64C5B2 21000004CF6096F0 21000004CF648010 215000C0FF00225B Port ID 0000CC 0000CB 0000CA 0000C9 0000C7 0000C6 0000CD
SEAGATE ST336752FSUN36G SEAGATE ST336752FSUN36G SEAGATE ST336752FSUN36G SEAGATE ST336752FSUN36G SEAGATE ST336752FSUN36G SEAGATE ST336752FSUN36G SUN StorEdge 3510F No device present No device present No device present No device present No device present No device present No device present No device present No device present
22
5. To exit the QLogic Fast!UTIL, press the Escape key, highlight Exit Fast!UTIL, and press Enter. The following QLogic Fast!UTIL menu is displayed.
QLogic Fast!UTIL Selected Adapter ---------------------------------------------------------Adapter Type I/O Address Slot Bus Device Function QLE2562 9400 01 02 01 1
---------------------------------------------------------Fast!UTIL Options Configuration Settings Scan Fibre Devices Fibre Disk Utility Loopback Data Test Select Host Adapter Exit Fast!UTIL
Chapter 2
23
24
CHAPTER
Software Installation
After you have completed the hardware installation and powered on the computer, follow the instructions in this chapter for your operating system to install the HBA driver and any other utilities required by the HBA. This chapter contains the following topics:
Installing Software for the Oracle Solaris OS on page 25 Installing Software for the Red Hat/SUSE Linux OS on page 27 Installing Software for the VMware Technology on page 31 Installing Software for the Windows OS on page 31 Installing a CLI for Updating the BIOS and FCode on page 33
Installing the Fibre Channel Driver on page 25 Diagnostic Support for the Oracle Solaris OS on page 26
25
Note Earlier versions of the Validation Test Suite software are referred to as
SunVTS software. Starting with the 7.0ps10 release, the software is referred to as OracleVTS software. The qlctest utility, which is provided as part of the SunVTS software, supports the following functions:
Connectivity verification Firmware version and checksum testing Self-testing Loopback tests
26
Downloading the Red Hat/SUSE Linux Drivers on page 27 Installing the Red Hat/SUSE Linux Drivers on page 28 Diagnostic Support for the Red Hat/SUSE OS on page 30
Note Because the driver distribution file is now larger than 1.44 Mb, it cannot fit
on a 1.44 Mb floppy disk; therefore, you must use a USB driver or local hard disk to download the file.
Chapter 3
Software Installation
27
2. Build and install the driver modules from the source code by executing the build.sh script.
# ./extras/build.sh install
Builds the driver .ko files. Copies the .ko files to the appropriate directory: /lib/modules/2.6.../kernel/drivers/scsi/qla2xxx Adds the appropriate directive in the modprobe.conf.local to remove the qla2xxx_conf module when unloading the qla2xxx module. Updates the newly built qla2xxx_conf.ko module with any previously saved data in /etc/qla2xxx.conf.
28
3. Choose how you want to load the driver, as described in To Load the Newly Built Fibre Channel Driver on page 29.
To Manually Load the Fibre Channel Driver on page 29 To Automatically Load the Fibre Channel Driver on page 29
3. If you want to manually unload the driver, use the modprobe -r command.
# modprobe -r qla2xxx # modprobe -r qla2xxx_conf (SANsurfer use only)
Chapter 3
Software Installation
29
3. For Red Hat Linux users, edit the /etc/modprobe.conf file and add the following entries, if they are not present:
alias scsi_hostadapter1 qla2xxx_conf (for use only with SANsurfer) alias scsi_hostadapter2 qla2xxx
4. For SUSE Linux users, edit the /etc/sysconfig/kernel file and modify the INITRD_MODULES directive as shown in the following example. In this example, note that you must add the first module, qla2xxx_conf (for SANsurfer), followed by the qla2xxx module. The qla2xxx_conf module is for use only with SANsurfer while the qla2xxx module is a common module.
... INITRD_MODULES=".... qla2xxx_conf qla2xxx" ...
8. Reboot the system to load the RAMDISK image with the driver.
Connectivity verification BIOS, FCode, EFI, and firmware version information Link status, including topology, data rate, and statistics Vital product data (VPD) information Attached devices list Option ROM, NVRAM update utilities Loopback test Read/Write Buffer test
30
The first line indicates that the fibre channel driver loaded successfully.
To Download the Fibre Channel Driver on page 32 To Install the Fibre Channel Driver on page 32
Chapter 3 Software Installation 31
Note This procedure requires a system configured with the latest Service Pack and
Windows Update. 1. On the first screen of the Found New Hardware wizard, click Search for a suitable driver for my device (recommended), and then click Next. 2. Browse to the location on the where you downloaded the Fibre Channel driver, then click Next. Windows displays a message, letting you know it found a driver for this device. 3. On the Completing the Found New Hardware Wizard window, click Finish. 4. If the system displays the following message, click Yes to restart the computer:
System Settings Change. Windows has finished installing a new device. The software that supports your device requires that you restart your computer. You must restart your computer before the new settings will take effect. Do you want to restart your computer now?
32
Connectivity verification BIOS, FCode, EFI, and firmware version information Link status, including topology, data rate, and statistics Vital Product Data (VPD) information Attached devices list Option ROM, NVRAM update utilities Loopback test Read/Write Buffer test
Chapter 3
Software Installation
33
Follow the installation instructions in the README.TXT file. Installation instructions are also available in the QLogic document, SANsurfer FC HBA CLI Users Guide (SN0054614-00), which can be found on the QLogic web site, http://www.qlogic.com. For instructions on how to update the BIOS and FCode, see the SANsurfer FC HBA CLI Users Guide at the QLogic web site.
34
CHAPTER
Known Issues
This chapter provides supplementary and workaround information about the HBA. The chapter contains the following topics:
35
36
APPENDIX
Declaration of Conformity on page 39 Safety Agency Compliance Statements on page 41 Regulatory Compliance Statements on page 57
37
38
Declaration of Conformity
To receive a copy of the latest Declaration of Conformity (DoC) for the product, either contact your local Oracle sales representative or send an email to: Compliance_Request_WW@oracle.com
39
40
Depending on the type of power switch your device has, one of the following symbols may be used: On Applies AC power to the system.
Safety Precautions
For your protection, observe the following safety precautions when setting up your equipment:
Follow all cautions and instructions marked on the equipment. Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the equipments electrical rating label. Never push objects of any kind through openings in the equipment. Dangerous voltages may be present. Conductive foreign objects could produce a short circuit that could cause fire, electric shock, or damage to your equipment. This product is intended for restricted access whereby access is controlled through the use of a means of security (for example, key, lock, tool, badge access) and personnel authorized for access have been instructed on the reasons for the restrictions and any precautions that need to be taken.
Modifications to Equipment
Do not make mechanical or electrical modifications to the equipment. Oracle is not responsible for regulatory compliance of a modified Oracle product.
Symbols
The following symbols may appear in this book: Caution There is a risk of personal injury and equipment damage. Follow the instructions.
SELV Compliance
Safety status of I/O connections comply to SELV requirements.
Caution Hot surface. Avoid contact. Surfaces are hot and may cause personal injury if touched.
Caution Hazardous voltages are present. To reduce the risk of electric shock and danger to personal health, follow the instructions.
41
Caution Not all power cords have the same current ratings. Do not use the power cord provided with your equipment for any other products or use. Household extension cords do not have overload protection and are not meant for use with computer systems. Do not use household extension cords with your Oracle product.
The following caution applies only to devices with a Standby power switch: Caution The power switch of this product functions as a standby type device only. The power cord serves as the primary disconnect device for the system. Be sure to plug the power cord into a grounded power outlet that is nearby the system and is readily accessible. Do not connect the power cord when the power supply has been removed from the system chassis. The following caution applies only to devices with multiple power cords: Caution For products with multiple power cords, all power cords must be disconnected to completely remove power from the system.
Battery Warning
Caution There is danger of explosion if batteries are mishandled or incorrectly replaced. On systems with replaceable batteries, replace only with the same manufacturer and type or equivalent type recommended by the manufacturer per the instructions provided in the product service manual. Do not disassemble batteries or attempt to recharge them outside the system. Do not dispose of batteries in fire. Dispose of batteries properly in accordance with the manufacturers instructions and local regulations. Note that on Oracle CPU boards, there is a lithium battery molded into the realtime clock. These batteries are not customer replaceable parts.
42
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Earthing Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (for example, use of power strips).
Elevated Operating Ambient If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply
Caution To prevent the rack from tipping during equipment installation, the anti-tilt bar on the rack must be deployed.
Caution To prevent extreme operating temperature within the rack insure that the maximum temperature does not exceed the products ambient rated temperatures.
43
Caution To prevent extreme operating temperatures due to reduced airflow consideration should be made to the amount of air flow that is required for a safe operation of the equipment.
Mesures de scurit
Caution Take adequate precautions when moving a rack or library that contains rackinstalled equipment. The weight of some rack equipment may have altered the rack or library center of gravity and could cause an overbalance/tip condition during a move. Pour votre scurit, nous vous recommandons de suivre scrupuleusement les mesures de scurit ci-dessous lorsque vous installez votre matriel:
Suivez tous les avertissements et toutes les instructions inscrites sur le matriel. Assurez-vous que la tension et la frquence de votre source d'alimentation correspondent la tension et la frquence indiques sur l'tiquette de la tension lectrique nominale du matriel N'introduisez jamais d'objets quels qu'ils soient dans les ouvertures de l'quipement. Vous pourriez vous trouver en prsence de hautes tensions dangereuses. Tout objet tranger conducteur risque de produire un court-circuit pouvant prsenter un risque d'incendie ou de dcharge lectrique, ou susceptible d'endommager le matriel. Ce produit est destin tre utilis dans des zones accs limit, dans lesquelles les accs sont contrls au moyen de systmes de scurit (par exemple, cl, verrou, dispositif ou badge). Le personnel autoris accder ces zones doit avoir t pralablement inform des raisons justifiant la limitation des accs et de toutes les prcautions prendre.
Caution For tape libraries, ensure that the equipment to be installed in the rack has UL Listing, CSA or C-UL Certification, and is CE marked.
Symboles
Vous trouverez ci-dessous la signification des diffrents symboles utiliss: Attention Vous risquez d'endommager le matriel ou de vous blesser. Veuillez suivre les instructions.
Attention Surfaces brlantes. Evitez tout contact. Les surfaces sont brlantes. Vous risquez de vous blesser si vous les touchez.
44
Attention Tensions dangereuses. Pour rduire les risques de dcharge lectrique et de danger physique, observez les consignes indiques. Selon le type d'interrupteur marche/arrt dont votre appareil est quip, l'un des symboles suivants sera utilis: Marche Met le systme sous tension alternative.
produits aliments en CC). Pour rduire les risques de dcharge lectrique, ne branchez jamais les produits Oracle sur une source d'alimentation d'un autre type. Contactez le grant de votre btiment ou un lectricien agr si vous avez le moindre doute quant au type d'alimentation fourni dans votre btiment.
Attention Tous les cordons d'alimentation ne prsentent pas les mmes caractristiques lectriques. Les cordons d'alimentation usage domestique ne sont pas protgs contre les surtensions et ne sont pas conus pour tre utiliss avec des ordinateurs. N'utilisez jamais de cordon d'alimentation usage domestique avec les produits Oracle. L'avertissement suivant s'applique uniquement aux systmes quips d'un interrupteur Veille: Attention L'interrupteur d'alimentation de ce produit fonctionne uniquement comme un dispositif de mise en veille. Le cordon d'alimentation constitue le moyen principal de dconnexion de l'alimentation pour le systme. Assurez-vous de le brancher dans une prise d'alimentation mise la terre prs du systme et facile d'accs. Ne le branchez pas lorsque l'alimentation lectrique ne se trouve pas dans le chssis du systme. L'avertissement suivant s'applique uniquement aux systmes quips de plusieurs cordons d'alimentation: Attention Pour mettre un systme quip de plusieurs cordons d'alimentation hors tension, il est ncessaire de dbrancher tous les cordons d'alimentation.
Modification du matriel
N'apportez aucune modification mcanique ou lectrique au matriel. Oracle dcline toute responsabilit quant la non-conformit ventuelle d'un produit Oracle modifi.
Conformit SELV
Le niveau de scurit des connexions E/S est conforme aux normes SELV.
Attention Ne mettez jamais des produits Oracle sous tension si leur couvercle suprieur n'est pas mis en place. Si vous ne prenez pas ces prcautions, vous risquez de vous blesser ou d'endommager le systme.
cas d'installation dans un chssis ferm ou contenant plusieurs appareils, la temprature ambiante de fonctionnement au niveau du rack peut tre suprieure la temprature ambiante de la pice. En consquence, il convient de veiller installer le matriel dans un environnement compatible avec la temprature ambiante maximale (Tma), spcifie par le fabricant.
rack doit tre effectue de faon ne pas compromettre le dbit d'air ncessaire pour un fonctionnement sr de ce matriel.
rack doit tre ralis de manire viter toute situation dangereuse rsultant d'une charge dsquilibre.
Surcharge de circuit : il convient de prendre les prcautions ncessaires pour la connexion du matriel au circuit d'alimentation et de rflchir aux consquences d'une ventuelle surcharge des circuits sur la protection de surintensit et sur le cblage d'alimentation. En l'occurrence, les valeurs nominales de la plaque signaltique du matriel doivent tre prises en compte. Mise la terre fiable : une mise la terre fiable du matriel mont en rack doit tre assure. Une attention toute particulire est requise pour les raccordements d'alimentation autres que ceux effectus directement sur le circuit principal (par exemple, en cas d'utilisation de blocs multiprises).
Couvercle de l'unit
Pour ajouter des cartes, de la mmoire ou des priphriques de stockage internes, vous devez retirer le couvercle de votre systme Oracle. Remettez le couvercle suprieur en place avant de mettre votre systme sous tension.
Attention Lquipement mont sur glissire/rail ne doit servir ni dtagre ni despace de travail.
46
modifier le centre de gravit du rack ou de la bibliothque pourrait provoquer un effet de contrepoids ou de dsquilibre durant le dplacement.
Attention Pour les bibliothques de bandes, vrifiez que le matriel installer dans le rack est homologu UL, CSA ou C-UL, et porte la mention CE.
Attention Afin d'viter que le rack ne penche pendant l'installation du matriel, tirez la barre anti-basculement du rack.
Attention Pour viter des tempratures de fonctionnement extrmes dans le rack, assurez-vous que la temprature maximale ne dpasse pas la fourchette de tempratures ambiantes du produit dtermine par le fabricant.
Priphriques CD et DVD
L'avertissement suivant s'applique aux priphriques CD, DVD et autres priphriques optiques: Attention L'utilisation de contrles et de rglages ou l'application de procdures autres que ceux spcifis dans le prsent document peuvent entraner une exposition des radiations dangereuses.
Attention Afin d'empcher des tempratures de fonctionnement extrmes provoques par une aration insuffisante, assurez-vous de fournir une aration approprie pour un fonctionnement du matriel en toute scurit.
Attention Prenez les prcautions adquates pour dplacer un rack ou une bibliothque qui contient du matriel install en rack. Le poids de certains quipements en rack ayant pu
47
Sicherheitsvorkehrungen
Treffen Sie zu Ihrem eigenen Schutz bei der Installation des Gerts die folgenden Sicherheitsvorkehrungen:
Beachten Sie alle auf den Gerten angebrachten Warnhinweise und Anweisungen. Stellen Sie sicher, dass Spannung und Frequenz der Stromversorgung den Nennleistungen auf dem am Gert angebrachten Etikett entsprechen. Fhren Sie niemals Fremdobjekte in die ffnungen am Gert ein. Es knnen gefhrliche Spannungen anliegen. Leitfhige Fremdobjekte knnen einen Kurzschluss verursachen, der einen Brand, Stromschlag oder Gerteschaden herbeifhren kann. Dieses Produkt unterliegt Zugangsbeschrnkungen. Der Zugang wird mithilfe eines Sicherheitsmechanismus kontrolliert (z. B. einem Schlssel, einer Sperre, einem Tool oder eines Werksausweises) und das autorisierte Zugangspersonal wurde ber die Grnde fr die Beschrnkungen und die zu treffenden Sicherheitsmanahmen unterrichtet.
Symbole
Die Symbole in diesem Handbuch haben folgende Bedeutung: Achtung Gefahr von Verletzung und Gerteschaden. Befolgen Sie die Anweisungen.
SELV-Konformitt
Der Sicherheitsstatus der E/A-Verbindungen entspricht den SELV-Anforderungen.
Achtung Gefhrliche Spannungen. Befolgen Sie die Anweisungen, um Stromschlge und Verletzungen zu vermeiden. Je nach Netzschaltertyp an Ihrem Gert kann eines der folgenden Symbole verwendet werden: Ein Versorgt das System mit Wechselstrom.
Achtung Nicht alle Netzkabel verfgen ber die gleichen Nennwerte. Herkmmliche, im Haushalt verwendete Verlngerungskabel besitzen keinen berlastschutz und sind
48
daher fr Computersysteme nicht geeignet. Verwenden Sie bei Ihrem Oracle-Produkt keine Haushalts-Verlngerungskabel. Die folgende Warnung gilt nur fr Gerte mit StandbyNetzschalter: Achtung Beim Netzschalter dieses Gerts handelt es sich nur um einen Ein/StandbySchalter. Zum vlligen Abtrennen des Systems von der Stromversorgung dient hauptschlich das Netzkabel. Stellen Sie sicher, dass das Netzkabel an eine frei zugngliche geerdete Steckdose in der Nhe des Systems angeschlossen ist. Schlieen Sie das Stromkabel nicht an, wenn die Stromversorgung vom Systemchassis entfernt wurde. Die folgende Warnung gilt nur fr Gerte mit mehreren Netzkabeln: Achtung Bei Produkten mit mehreren Netzkabeln mssen alle Netzkabel abgetrennt werden, um das System vllig von der Stromversorgung zu trennen.
Werfen Sie die Batterien nicht ins Feuer. Entsorgen Sie die Batterien entsprechend den Anweisungen des Herstellers und den vor Ort geltenden Vorschriften. CPU-Karten von Oracle verfgen ber eine Echtzeituhr mit integrier-ter Lithiumbatterie. Diese Batterie darf nur von einem qualifizierten Servicetechniker aus-gewechselt werden.
Gehuseabdeckung
Sie mssen die Abdeckung Ihres Oracle-Computersystems entfernen, um Karten, Speicher oder interne Speichergerte hinzuzufgen. Bringen Sie vor dem Einschalten des Systems die Gehuseabdeckung wieder an.
Achtung Nehmen Sie Oracle-Gerte nicht ohne Abdeckung in Betrieb. Die Nichtbeachtung dieses Warnhinweises kann Verletzungen oder Gerteschaden zur Folge haben.
49
Rack in einer geschlossenen Rack-Baugruppe oder in einer Multi-unit-Rack-Baugruppe installiert ist, kann die Betriebsumgebungstemperatur der RackUmgebung hher sein als die Umgebungstemperatur des Raumes. Deshalb sollte bercksichtigt werden, das Gert in einer Umgebung zu installieren, die kompatibel zu der vom Hersteller angegebenen maximalen Umgebungstemperatur (Tma) ist.
einem Rack sollte so erfolgen, dass die Luftstrommenge, die fr den sicheren Betrieb des Gerts erforderlich ist, nicht beeintrchtigt wird.
Mechanische Belastung - Die Montage des Gerts im Rack sollte so erfolgen, dass bei einer ungleichmigen mechanischen Belastung keine gefhrliche Betriebsbedingung entstehen kann. Stromkreisberlastung - Der Anschluss des Gerts an
den Speisestromkreis und die Wirkung, die ein berlasten der Stromkreise auf das berstromschutzGert und die Speisestromkreisverkabelung haben kann, sollten sorgfltig geprft und bercksichtigt werden. Beim Behandeln dieses Aspekts sollten besonders die Lastangaben auf dem Leistungsschild des Gerts sorgfltig geprft werden.
Achtung Verwenden Sie beim Einbau den Kippschutz am Rack, um ein Umkippen zu vermeiden.
Zuverlssige Erdung - Ausrstung, die in Racks montiert ist, muss zuverlssig geerdet sein. Besonders mssen hierbei die Stromanschlussleitungen und weniger die direkten Verbindungen zum Abzweigstromkreis beachtet werden (z. B. durch die Verwendung von Adapterleisten).
Achtung Um extreme Betriebstemperaturen im Rack zu vermeiden, stellen Sie sicher, dass die Maximaltemperatur die Nennleistung der Umgebungstemperatur fr das Produkt nicht berschreitet
Achtung Verwenden Sie Gerte in Steckpltzen bzw. auf Schienen nicht als Regal oder Arbeitsbereich.
Achtung Um extreme Betriebstemperaturen durch verringerte Luftzirkulation zu vermeiden, sollte die fr den sicheren Betrieb des Gerts erforderliche Luftzirkulation eingesetzt werden.
Achtung Treffen Sie ausreichende Vorkehrungen, wenn Sie ein Rack oder eine Bibliothek bewegen, die rackmontierte Gerte enthlt. Durch das Gewicht mancher Ausrstungsteile im Rack wurde mglicherweise der Schwerpunkt des Racks bzw. der Bibliothek verndert, was zu einem Ungleichgewicht bzw. Umkippen eines Ausrstungsteils whrend einer Bewegung fhren kann.
50
Achtung Stellen Sie bei Bandbibliotheken sicher, dass auf den im Rack zu installierenden Gerten das UL-Prfzeichen, die CSA- bzw CUL-Zertifizierung, und die CE-Kennzeichnung angebracht sind.
Asegrese de que el voltaje y frecuencia de la fuente de alimentacin coincidan con el voltaje y frecuencia indicados en la etiqueta de clasificacin elctrica del equipo. No introduzca objetos de ningn tipo por las rejillas del equipo, ya que puede quedar expuesto a voltajes peligrosos. Los objetos conductores extraos pueden producir cortocircuitos y, en consecuencia, incendios, descargas elctricas o daos en el equipo. Este producto se ha concebido para un acceso restringido y, por tanto, ste se controla mediante mecanismos de seguridad (p. ej., acceso con clave, bloqueo, herramienta y tarjeta de identificacin). Las personas con acceso autorizado estn al corriente de los motivos de esta restriccin y de las precauciones que se deben tomar.
Smbolos
En este documento aparecen los siguientes smbolos: Precaucin Existe el riesgo de que se produzcan lesiones personales y daos en el equipo. Siga las instrucciones.
Precaucin Superficie caliente. Evite todo contacto. Las superficies estn calientes y pueden causar lesiones personales si se tocan.
Precaucin Voltaje peligroso. Para reducir el riesgo de descargas elctricas y lesiones personales, siga las instrucciones. En funcin del tipo de interruptor de alimentacin del que disponga el dispositivo, se utilizar uno de los smbolos siguientes: Encendido Suministra alimentacin de CA al sistema.
Normativas de seguridad
Lea esta seccin antes de realizar cualquier operacin. En ella se explican las medidas de seguridad que debe tomar al instalar un producto de Oracle.
Medidas de seguridad
Para su proteccin, tome las medidas de seguridad siguientes durante la instalacin del equipo:
51
cuentan con proteccin frente a sobrecargas y no estn diseados para su utilizacin con sistemas informticos. No utilice alargadores de uso domstico con el producto Oracle. La siguiente medida solamente se aplica a aquellos dispositivos que dispongan de un interruptor de alimentacin de espera: Precaucin El interruptor de alimentacin de este producto funciona solamente como un dispositivo de espera. El cable de alimentacin hace las veces de dispositivo de desconexin principal del sistema. Asegrese de que conecta el cable de alimentacin a una toma de tierra situada cerca del sistema y de fcil acceso. No conecte el cable de alimentacin si la unidad de alimentacin no se encuentra en el bastidor del sistema. La siguiente medida solamente se aplica a aquellos dispositivos que dispongan de varios cables de alimentacin: Precaucin En los productos que cuentan con varios cables de alimentacin, debe desconectar todos los cables de alimentacin para cortar por completo la alimentacin elctrica del sistema.
Modificaciones en el equipo
No realice modificaciones de tipo mecnico ni elctrico en el equipo. Oracle no se hace responsable del cumplimiento de normativas en caso de que un producto Oracle se haya modificado.
Precaucin No todos los cables de alimentacin tienen la misma clasificacin elctrica. Los alargadores de uso domstico no
52
descritas en el manual de servicio del producto. No desmonte las bateras ni intente recargarlas fuera del sistema. No intente deshacerse de las bateras echndolas al fuego. Deshgase de las bateras correctamente de acuerdo con las instrucciones del fabricante y las normas locales. Tenga en cuenta que en las placas CPU de Oracle, hay una batera de litio incorporada en el reloj en tiempo real. Los usuarios no deben reemplazar este tipo de bateras.
en un armario cerrado o con ms unidades, la temperatura ambiente de funcionamiento del entorno del armario puede ser superior a la de la habitacin. Por tanto, el equipo debera instalarse en un entorno compatible con la temperatura ambiente mxima (Tma) especificada por el fabricante.
armario hay que asegurarse de que se mantendr el flujo de aire necesario para el correcto funcionamiento del equipo.
Carga mecnica - el montaje del equipo en el armario debera realizarse de modo que no se d una situacin de peligro debido a una carga mecnica irregular. Sobrecarga del circuito - debe prestarse atencin a la conexin del equipo al circuito de alimentacin y a las consecuencias que puede tener la sobrecarga de los circuitos en la proteccin de sobrecorriente y el cableado de alimentacin. En caso de sobrecarga, es recomendable tener en cuenta la potencia del equipo que aparece en la placa de identificacin. Puesta a tierra fiable - debera mantenerse una puesta a tierra fiable del equipo montado en un armario. Debera prestarse especial atencin a las conexiones de suministro que no sean las directas al circuito derivado (p. ej., las regletas de distribucin).
Precaucin Los equipos instalados por deslizamiento o sobre rales no deben utilizarse como estantera o espacio de trabajo.
53
Precaucin Por seguridad, siempre deben montarse los equipos de abajo arriba. A saber, primero debe instalarse el equipo que se situar en el bastidor inferior; a continuacin, el que se situar en el siguiente nivel, etc.
la utilizacin de lser
Los productos Oracle que utilizan tecnologa lser cumplen los requisitos establecidos para los productos lser de clase 1.
Precaucin Para evitar que el bastidor se vuelque durante la instalacin del equipo, debe extenderse la barra antivolcado del bastidor.
Precaucin Para evitar que se alcance una temperatura de funcionamiento extrema en el bastidor, asegrese de que la temperatura mxima no sea superior a la temperatura ambiente establecida como adecuada para el producto.
Dispositivos de CD y DVD
La siguiente medida se aplica a los dispositivos de CD y DVD, as como a otros dispositivos pticos: Precaucin La utilizacin de controles, ajustes o procedimientos distintos a los aqu especificados puede dar lugar a niveles de radiacin peligrosos.
Precaucin Para evitar que se alcance una temperatura de funcionamiento extrema debido a una circulacin de aire reducida, debe considerarse la magnitud de la circulacin de aire requerida para que el equipo funcione de forma segura.
Norge
Advarsel Litiumbatteri Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Brukt batteri returneres apparatleverandren.
Sverige
Precaucin Para libreras de cintas, compruebe que el equipo que vaya a instalarse en el bastidor tenga la certificacin UL Listing, CSA o C-UL, y la marca CE. Varning Explosionsfara vid felaktigt batteribyte. Anvnd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera anvnt batteri enligt fabrikantens instruktion.
54
Danmark
Advarsel! Litiumbatteri Eksplosionsfare ved fejlagtig hndtering. Udskiftning m kun ske med batteri af samme fabrikat og type. Levr det brugte batteri tilbage til leverandren.
Norge
Advarsel Apparatet m tilkoples jordet stikkontakt.
Sverige
Varning Apparaten skall anslutas till jordat uttag.
Suomi
Varoitus Paristo voi rjht, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hvit kytetty paristo valmistajan ohjeiden mukaisesti.
Suomi
Varoitus Laite on liitettv suojamaadoituskoskettimilla varustettuun pistorasiaan.
Danmark
Advarsel! Dette produkt er ogs beregnet til et IT-strmfordelingssystem med en fase-tilfase spnding p 230 V.
55
56
57
58
QLC-D17
59
60