This chapter identifies specific parts of the LM6000 PC engine that are cyclic life-limited as a result of normal operation. Instructions for tracking the operating hours and operating cycles for such parts that have been identified as being limited in terms of operating service, are also provided. Critical life-limited parts are those parts that, should they suddenly fail, could threaten the structural integrity of the engine or its package. Stress cycles on gas turbine parts result from transients of speed and temperature that occur during starts, accelerations, and decelerations. Therefore, life limits are expressed in terms of engine cycles and can be related to normal operational data. Cycles are defined in paragraph 13-2, Definitions. Life limits of critical parts are established through analysis and testing. Accumulated cycles are to be calculated, tracked, and compared to published life limits to determine when a part should be permanently retired from service. No component shall be allowed to remain in service beyond its published life limit. Paragraph 13-5 defines how cycles are to be calculated.
13-2 Definitions
The following terms are used in this chapter: a. Full Cycle: A full cycle is defined as a cycle from zero gas generator speed with acceleration to high power setting, followed by shutdown of the gas turbine. High power setting is considered to be any power setting above synchronous idle where the generator breaker is closed.
Change 9 GE PROPRIETARY INFORMATION - Subject to the restrictions on the cover or first page.
13-1
b.
Partial Cycle: A partial cycle is defined as any decrease in power (mW) greater than X percent from a current steady state power (any power setting above idle) to any controlled lower power setting, followed by a subsequent increase in power (>10 percent). Steady state power is considered to be any power setting above synchronous idle where the generator breaker is closed. If X = 0-50, then Kp = 0 If X >50, and 75, then Kp = 0.1 If X >75, and 100, then Kp = 0.75
g.
Partial Cycle Factor: Coefficient used as a numeric expression of the amount of damage caused by a partial cycle (Kp). Trip Cycle Factor: Coefficient used as a numeric expression of the amount of damage caused by a trip cycle (Kt).
h.
c.
Trip Cycle: A trip cycle is defined as a cycle from zero gas generator speed with acceleration to high power setting (any power setting above synchronous idle), followed by rapid (uncontrolled) shutdown. An example would be a fuel metering valve being immediately closed. A decel-tominimum load or step-to-idle are not considered trip cycles for the purpose of Critical Parts Life Management. Declared Life: Declared life is the cyclic life limit of a critical lifelimited part. Accumulated Cycles: Accumulated cycles represent the calculated life consumed by a part, considering both full, partial, and trip cycles experienced by the part during operation. Full Cycle Factor: Coefficient used as a numeric expression of the amount of damage caused by a full cycle (Kf).
d.
e.
f.
13-2
Change 9 GE PROPRIETARY INFORMATION - Subject to the restrictions on the cover or first page.
a.
Accumulated Cycles = (Kf x Full Cycles) + (Kp x Partial Cycles) + (Kt x Trip Cycles) The coefficients Kf, Kp, and Kt are listed for each component in table 13-1.
b.
The owner/user is responsible for the maintenance of accurate records of all engine hours and cycles. The operator should monitor status of the parts to ensure that none listed in table 13-1 exceed the declared life limits published in this chapter.
Change 9 GE PROPRIETARY INFORMATION - Subject to the restrictions on the cover or first page.
13-3
LM6000 PC GE Industrial AeroDerivative Gas Turbines Table 13-1 Declared Life Limits for LM6000 PC Engine
Module LPCR
Component
Part Number
Kf
Kp
Kt
Stg 0 Disk Stg 1 Disk Stg 2-4 Spool LPC Fwd Shaft LPC Fwd Shaft FMS Fwd Shaft Mid Shaft HPCR Stg 1 Disk Stg 2 Disk Stg 2 Disk Stg 3-9 Spool Stg 3-9 Spool Stg 10-14 Spool CDP Seal CDP Seal HPTR Stg 1 Disk Stg 1 Disk Stg 2 Disk Stg 2 Disk
L24546P05 L24547P03 1781M30G04 L24548P06 L44648G01, G02 9080M27P09 L47747P01, P02, P03 9380M26P06 9380M27P08 9380M27P10 1333M66G10 1333M66G09, G13, G14, and L44659P01 1703M49G01, G02, G03, G04 L47299P02 L47299P03, 1782M82P02, P03, and L43372P04 1531M84G10, G12 1531M84G11 9362M43P05 9362M43P10
20,000 20,000 20,000 20,000 TBD 8,500 TBD 11,200 17,200 TBD 11,900 TBD TBD 11,300 TBD
See Note 1
1 1 1 1 TBD 1 TBD 1.97 1.96 TBD 1.76 TBD TBD 3.94 TBD
1 TBD 1 TBD
13-4
Change 9 GE PROPRIETARY INFORMATION - Subject to the restrictions on the cover or first page.
LM6000 PC GE Industrial AeroDerivative Gas Turbines Table 13-1 Declared Life Limits for LM6000 PC Engine (Continued) Module LPTR Stg 1 Disk Stg 1 Disk Stg 2 Disk Stg 2 Disk Stg 3 Disk Stg 4 Disk Stg 5 Disk Shaft Balance Piston L47741P01 L47741P02 L47742P01 L47742P02 L47743P02 L47744P02, P03 L47745P02 L47746P01 L45001P07 and L47958P01, P02 20,000 TBD 16,400 TBD TBD TBD TBD TBD TBD 1 TBD 1 TBD TBD TBD TBD TBD TBD Component Part Number Industrial Life Limit (Cycles) Kf Kp
Kt
See Note 1
TBD TBD TBD TBD TBD TBD TBD TBD TBD
Note 1: For appropriate partial cycle factor (Kp), refer to Partial Cycle definition in paragraph 13-2.b.
Change 9 GE PROPRIETARY INFORMATION - Subject to the restrictions on the cover or first page.
13-5
13-6
Change 9 GE PROPRIETARY INFORMATION - Subject to the restrictions on the cover or first page.
This appendix contains specifications for the following: A1 A2 A3 A4 A5 A6 Natural Gas Fuel Liquid Fuel Water Purity - NOx Suppression Water Purity - Compressor Cleaning Liquid Detergent - Compressor Cleaning Lubricating Oil
Change 6
A-1(A-2 Blank)