Sei sulla pagina 1di 3

AXN1600 and AXN600 Product Release Notes

Software Version - Beta Release 1.1

Version 1.1 Release Notes

09/08/01

This document list the new S/W and H/W features supported in beta release 1.1 of the AXN Multiservice IP Concentrator. Please note that the status of this release is still beta not yet commercially available. For features that already supported please refer to release note 1.0

Hardware Features
This release doesnt contain any new hardware features.

Software Features
1. Access Privilege to the AXN CLI The AXN supports 4 levels of access privilege through the CLI. Each user accessing the AXN CLI is pre-classified to one out of 4 groups. Each group is assigned with certain permission. The permissions allow the members of this group to perform operations according to a list of commands defined particularly to this group. The following are the 4 groups of access levels: a. Administrator - the highest level. Authorized to perform any Read /Write operation of all parameters including setting security information such as IP address of authorized management stations. There is only one administrator per AXN node. b. Configuration members of this group are authorized to perform Read/Write operations of all parameters. They are not allowed to set any security parameters. Typically, they will configure the multiservice connections, the routing tables, etc. c. Technician members of this group are authorized to perform maintenance operations such as loop-back, counters reset but are not allowed to modify any configuration parameters. d. Read the lowest access privilege level. Readers are authorized to perform only read operations of all parameters. 2. Trusted client for Telnet The AXN maintains a list of trusted source IP addresses. This list contains explicit IP addresses in dot notation. The AXN check every incoming Telnet session for its source. If the source is "trusted", session can be established. If the source is not "trusted", the session is closed and the reason of violation is logged. 3. Disable responding to SNMP queries a new CLI command allows the AXN node to support enable/disable responding to SNMP commands. 4. History of Command the AXN CLI keep history of the last 20 CLI commands.

Version 1.1 Release Notes

09/08/01

5. SYSLOG support the AXN now supports interface to SYSLOG server. This version sends to the SYSLOG server pre-selected events only. Typical events supported with this release are alarms, login/logout, and card-in/card-out. 6. Timing holdover in the INI this feature ensures that in case of failure in the primary timing source in the INI, the affect on the clock frequency while switching to the secondary source will be minimize. 7. RADIUS client a RADIUS client was integrated into the AXN to perform users authentication and authorization.

Unresolved Issues
The following table summarizes release 1.1 unresolved issues. These issues are scheduled to be fix in the upcoming S/W release of the AXN. # 1 2 Description The following occurs when returns from holdover timing mode: it takes the clock between 1-2 sec till it stables again resulting in 2 ES. Randomly, the AXN set false alarm on the primary clock. This alarms remains for few seconds and then disappears. It doesnt interrupt traffic.

Resolved Issues
The following table summarizes release 1.1 resolved issues. # 1 2 Description Successive insertion and removal of the INI Interface Module (IM-INI) will result with the stuck of INI card. Solution identified and implemented. The following can occur when one the cards performs reset process: the pending keep alive signal can trigger additional card reset. Fixed.