Sei sulla pagina 1di 4

Burners Flares Incinerators Aftermarket Products & Services

Customer name _ Customer ref # User name____________________________ Jobsite location Zeeco Inc. ref # Date: _________________Revision #: _____

FLARE SYSTEM DATA SHEET


FLARE TYPE: Elevated Flare Self-supported Enclosed Ground Flare Derrick Supported Gas assisted Pit Flare Multipoint Ground Flare Air-assisted Sonic MJ None None Tripod Supported Enclosure Fence Guy Wire Supported FLARE TIP: DRUM TYPE:

Non-assisted

Steam assisted

Vertical Knockout Gas Purge Seal

Liquid Seal

Horizontal Knockout

PURGE SEAL TYPE:

Velocity Purge Seal


3

UNITS FOR DATA SHEET: KG/HR LB/HR Flow: Temperature: Pressure: Radiation: PROCESS DATA:
PROCESS RELIEF CASE FLOWRATE
o

SCFD
o

NM /HR BTU/SCF KG/CM2 FT/SEC Velocity: KPAG

LBMOLES/HR BTU/LB MPH KJ/NM 3 M/SEC

Heating Value: KW/M 2

PSIG BTU/HR-FT2

BARG

TEMPERATURE

ALLOWABLE SYSTEM PRESSURE DROP

LOWER HEATING VALUE

RELIEF DURATION
SHORT/LONG/ CONTINUOUS

MOLECULAR WEIGHT

Maximum Smokeless Normal Minimum

UTILITY DATA: UTILITY Fuel Gas Natural Gas Purge Gas Instrument Air Plant Air Plant Water LP Steam MP Steam HP Steam NA NA 18 18 18 18 22151 E. 91st St. Broken Arrow, OK, USA PAGE 1 NA NA NA NA NA NA PRESSURE TEMPERATURE MOLECULAR WEIGHT LOWER HEATING VALUE

9/10/2009

Zeeco Inc.

74014

Burners Flares Incinerators Aftermarket Products & Services

Customer name _ Customer ref # User name____________________________ Jobsite location Zeeco Inc. ref # Date: _________________Revision #: _____ PHASE HERTZ AC or DC

POWER TYPE General Instruments General Lighting Aviation Lighting Ignition Control Panel Motors Under 100 HP Motors 101-500 HP Motors 501-1000 HP ENVIRONMENTAL DATA:

VOLTAGE

Average wind speed (process design) Maximum wind speed (mechanical design) Site elevation above sea level Site relative humidity Minimum ambient temperature Average ambient temperature Maximum ambient temperature Seismic zone for site Maximum allowable radiation: of: Solar radiation level at site Maximum noise level (dBa): of: Electrical area classification at / near flare CUSTOMER AND JOBSITE INFORMATION: Customer name Street address Post office box City/State/Country/Zip Contact name Phone number Facsimile number 9/10/2009 Zeeco Inc. End users name Street address Post office box City/State/Country/Zip Contact name Phone number Facsimile number 22151 E. 91st St. Broken Arrow, OK, USA PAGE 2 74014 at grade at distance smokeless smokeless max. flow max. flow at grade at distance with with without solar without solar

Burners Flares Incinerators Aftermarket Products & Services

Customer name _ Customer ref # User name____________________________ Jobsite location Zeeco Inc. ref # Date: _________________Revision #: _____

GENERAL DESIGN CRITERIA: Rank the following factors in order of importance (1-8)(1=high) relative to the flare equipment for this project: Equipment cost Installed cost Utility usage Smokeless capacity NEC AWS Experience Weight IEC ASME Noise Field service NEMA ANSI B31.3 AISC ASCE 7-93

Applicable specifications:

DETAILED SCOPE OF SUPPLY: Ladders/platforms: Ignition system: Per OSHA Caged Saf-T-Climb Galvanized Painted

Manual Automatic relight Sun/rain shield Free standing Direct high energy spark ignition Per ICAO L+P access Per FAA Strobe type

Pilot status monitors Regulators Self-inspirating type FFG type Optical pilot monitoring device Fixed Retractable Incandescent type Banded paint

Aviation marking:

Utility piping/wiring:

Pilot gas Ignition lines Steam lines Conduit Assist gas Thermocouple wire High energy ignitor wire Power wire SP-2 cleaning SP-6 sandblast SP-10 sandblast Other___________ Red oxide primer Inorganic zinc primer Epoxy primer Epoxy finish paint Silicone finish paint Other______________

Corrosion protection:

DETAILED MECHANICAL DESIGN CRITERIA: SYSTEM COMPONENT Liquid Seal drum Knockout drum Flare gas riser Gas Purge seal device Support structure Steam piping Pilot gas piping Ignition piping NA NA NA INTERNAL DESIGN PRESSURE MECHANICAL DESIGN TEMPERATURE MATERIAL OF CONSTRUCTION PROCESS SIDE CORROSION ALLOWANCE

NOTE: Attach sketch if this is for modification to an existing flare system or existing vent system.
9/10/2009 Zeeco Inc. 22151 E. 91st St. Broken Arrow, OK, USA PAGE 3 74014

Burners Flares Incinerators Aftermarket Products & Services

Customer name _ Customer ref # User name____________________________ Jobsite location Zeeco Inc. ref # Date: _________________Revision #: _____ Weight % NORMAL FLOW CASE MINIMUM FLOW CASE PILOT FUEL GAS

GAS COMPOSITION: COMPONENT Methane Ethane Propane Butane Pentane Hexane Heptane Octane C9+ Saturates Ethylene Propylene Butylene Butene Butadiene Acetylene Benzene Toluene Xylene Styrene C9+ Unsaturates Ammonia Hydrogen Hydrogen Sulfide Carbon Monoxide Carbon Dioxide Water Nitrogen Oxygen MAXIMUM FLOW CASE

Mole % SMOKELESS FLOW CASE

COMMENTS: ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ 9/10/2009 Zeeco Inc. 22151 E. 91st St. Broken Arrow, OK, USA PAGE 4 74014