Sei sulla pagina 1di 5

GE Lighting DATA SH EE T

Kolorlux
High pressure Mercury lamps Kolorlux Standard 50W, 80W, 125W, 250W and 400W Kolorlux Deluxe 50W, 80W, 125W, 250W and 400W Product information
Kolorlux Mercury vapor lamps are often used due to their relative efficiency. Phosphor coated bulbs offer a better color rendering index than either high or low pressure sodium lamps. Kolorlux lamps are available in both standard and deluxe versions with an elliptical coated bulb shape and wattages of 50-400.

Features
Kolorlux Mercury lamps offer white light with good color rendering (40-53 Ra). You can depend on these lamps for long term reliability and their modest to low operating costs. Mercury lamps provide intense lighting for a wide range of applications.

Application areas
Streetlighting Amenityareas Security Parkinglots&garages Areafloodlighting Warehousing Industrialunits

Compliance with IEC standards


AllKolorluxLampscomplywithIEC60188.

Basic data
Product Code Nominal Wattage [W] Rated Wattage [W] Volts [V] Cap Product Descripton Nominal Lumen [lm] 1800 3800 3800 6300 6300 13000 22500 1800 3800 6500 13800 24400 Rated Lumen [lm] 2010 3990 4070 6620 6620 13620 25000 1880 3930 6520 13990 25600 Rated Lamp Efficacy [lm/W] 39 48 49 51 51 54 62 36 48 51 56 64 Mercury Content [mg] 9.0 13.0 13.0 21.0 21.0 41.0 65.0 9.0 13.0 21.0 41.0 65.0 Rated Average Life [hr] 16000 20000 20000 20000 20000 20000 20000 16000 20000 20000 20000 20000 CCT [K] Color Ambient Rendering Temp. Index [Ra] [C] 40 45 45 45 45 45 40 52 53 53 45 47 25 25 25 25 25 25 25 25 25 25 25 25

Kolorlux Mercury Standard 74171 50 52 74172 74173 73736 77071 73737 74174 80 80 125 125 250 400 82 82 129 129 251 401

95 115 115 125 125 130 135 95 115 125 130 135

E27 E27 B22 E27 B22 E40 E40 E27 E27 E27 E40 E40

H50 E27 H80 E27 H80 B22 H125 E27 H125 B22 H250 E40 H400 E40 H50 DX E27 H80 DX E27 H125 NDX E27 H250 NDX E40 H400 DX E40

4000 4000 4000 4000 4000 4000 4000 3700 3600 3500 3400 3400

Kolorlux Mercury Deluxe 77055 50 52 77056 77057 77058 77061 80 125 250 400 83 127 250 401

Dimensions
B
Watts A Length [mm] B Diameter [mm] 55 70 75 90 120 55 70 75 90 120 Cap Bulb Weight [g] 53 63 83 160 230 53 63 83 160 230 Operating Postition Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Minimum Starting Temperature [C] -18C -18C -18C -18C -18C -18C -18C -18C -18C -18C

Kolorlux Mercury Standard 50 130 80 125 250 400 156 170 227 292

E27 E27 E27 E40 E40 E27 E27 E27 E40 E40

Soft Soft Soft Hard Hard Soft Soft Soft Hard Hard

Kolorlux Mercury Deluxe 50 130 80 125 250 400 156 170 227 292

Survival rate and lumen maintenance


The graph shows the survival of representative groups of lamps operated under controlled conditions at 10 hrs/start.Lamp life in service will be affected by a number of parameters, such as mains voltage deviations, switching cycle, luminaire design and control gear. The information given is intended to be a practical guide in determining lamp replacement schedules. Kolorlux 50W
100% 100%

Kolorlux 80-400W

75%

75%

% of initial

50%

% of initial

50%

25%

Lumen maintenance Lamp survival

25%

Lumen maintenance Lamp survival

0%

12

16

0%

12

16

20

Burning time (thousand hours)

Burning time (thousand hours)

Lamp survival (%)


Burning Time (thousand hours) Watts 0.1 2 99.3 99.5 99.5 99.5 99.5 99.3 99.5 99.5 99.5 99.5 4 96.4 97.8 97.8 97.8 97.8 96.4 97.8 97.8 97.8 97.8 6 91.4 94.8 94.8 94.8 94.8 91.4 94.8 94.8 94.8 94.8 8 84.8 90.0 90.0 90.0 90.0 84.8 90.0 90.0 90.0 90.0 12 68.1 78.0 78.0 78.0 78.0 68.1 78.0 78.0 78.0 78.0 16 49.9 63.0 63.0 63.0 63.0 49.9 63.0 63.0 63.0 63.0 20 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 Kolorlux Mercury Standard 50 100 80 100 125 100 250 100 400 100 Kolorlux Mercury Deluxe 50 100 80 100 125 100 250 100 400 100

Lumen output (000)


Burning Time (thousand hours) Watts 0.1 2 1.63 3.44 5.70 11.76 20.36 1.63 3.44 5.97 12.49 22.08 4 1.49 3.14 5.20 10.73 18.57 1.49 3.14 5.45 11.39 20.14 6 1.36 2.87 4.76 9.83 17.01 1.36 2.87 4.99 10.43 18.44 8 1.26 2.65 4.40 9.08 15.71 1.26 2.65 4.61 9.64 17.04 12 1.12 2.37 3.94 8.12 14.06 1.12 2.37 4.12 8.62 15.25 16 1.03 2.17 3.60 7.43 12.86 1.03 2.17 3.77 7.89 13.94 20 1.99 3.30 6.81 11.79 1.99 3.46 7.23 12.78 Kolorlux Mercury Standard 50 1.80 80 3.80 125 6.30 250 13.0 400 22.5 Kolorlux Mercury Deluxe 50 1.80 80 3.80 125 6.30 250 13.0 400 24.4

Spectral power distribution


Kolorlux Standard
100% 75% 100% 75%

Kolorlux Deluxe

Relative intensity

75% 50% 50% 25% 0% 380 430 480 530 580 630 680 730

Relative intensity

75% 50% 50% 25% 0% 380 430 480 530 580 630 680 730

Wavelength [nm]

Wavelength [nm]

Photometric data
Watts 100 Hours Lumens Colour Temperature [K] 4,000 4,000 4,000 4,000 4,000 3,700 3,600 3,500 3,400 3,400 CRI [Ra] DIN5035 Classification 3 3 3 3 3 3 3 3 3 3 Kolorlux Mercury Standard 50 1,800 80 3,800 125 6,300 250 13,000 400 22,500 Kolorlux Mercury Deluxe 50 1,800 80 3,800 125 6,500 250 13,800 400 24,400

45 45 45 45 40 53 53 53 50 47

Electrical data
Dataisbasedonanominallampoperatingonanominalchoke(reactor)ballastwithpowerfactorcorrection.Supplypoweris based on a typical commercially available ballast.
Watts 50 80 125 250 400
* +/- 10V

Volts 15 [V] 95* 115 125 130 135

Current [A] 0.61 0.8 1.15 2.13 3.25

Power [W] 50 80 125 250 400

Current Crest Factor 1.8 1.8 1.8 1.8 1.8

Run-up characteristics
% change from nominal

Typical run-up characteristics


180 160 140 120 100 80 Ulamp Ilamp Plamp Lumen 60 40 20 0

Time for the light output to reach 90% of the final value is determined by supply voltage and ballast design. Typical values are:
Watts Run-up [mins] 50 6 80 5 125 5 250 5 400 5

Hot re-strike time

100

200

300

400

500

600

Time from switch on (seconds)

Allratingsre-strikewithin4-7minutesfollowingashortinterruptioninthesupply.Actualre-striketimeisdeterminedby cooling rate of the lamp.

Supply voltage
Lamps are suitable for supplies in the range 220V to 250V50/60Hzforappropriatelyratedserieschoke(reactor) ballasts. Supplies outside this range require a transformer (conventional,highreactanceorCWA)toensurecorrectlamp operation. Lamps start and operate at 10% below the rated supply voltage when the correct control gear is used. However in order to maximise lamp survival, lumen maintenance and colour uniformity the supply voltage and ballast design voltage should be within 3%. Supply variations of 5% are permissible for short periods only. Effect of supply voltage variation
35 30 25

% change from nominal

20 15 10 5 0 -5 Lamp voltage Lamp current Lamp wattage Lamp lumens -10 -15 -20 -25 -30 -35 -10 -8 -6 -4 -2 0 2 4 6 8 10

% change in mains voltage

Guidance for luminaire manufacturers


Lamp operating temperature limits
Watts 50-125W 250-400W Watts 50-125W 250-400W Maximum Cap Temperature 210C 250C Maximum Bulb Temperature 300C 400C

Control gear
To achieve correct lamp starting, performance and life, it is important that lamp and control gear are compatible and suitably rated for the supply voltage at the luminaire.

Ballasts
LampsarefullycompatiblewithballastsmanufacturedforhighpressuremercurylampstoIEC60188.Ballastsshouldcomply withspecificationsIEC60262.

Ballast thermal protection


Use of ballasts incorporating thermal cut-out is not a specific requirement but is a good optional safety measure for the installation.

Ballast voltage adjustment


Serieschoke(reactor)ballastsincorporatingadditionaltappingsat10Voftheratedsupplyvoltagearerecommended. Alternatively a single additional tapping 10V above the rated supply voltage will ensure lamps are not overloaded due to excessive supply voltage.

PFC capacitors for choke (reactor) circuits


PowerFactorCorrectionisadvisableinordertominimisesupplycurrentandelectricitycosts.For220-250Vsupplies 250V10% rated capacitors are recommended as follows:
Watts PFCCapacitor[F] 50 6 80 8 125 8 250 13 400 20

www.gelighting.com/eu
andGeneralElectricarebothregisteredtrademarks oftheGeneralElectricCompany

GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. Kolorlux Data Sheet October 2011