Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Kolorlux
High pressure Mercury lamps Kolorlux Standard 50W, 80W, 125W, 250W and 400W Kolorlux Deluxe 50W, 80W, 125W, 250W and 400W Product information
Kolorlux Mercury vapor lamps are often used due to their relative efficiency. Phosphor coated bulbs offer a better color rendering index than either high or low pressure sodium lamps. Kolorlux lamps are available in both standard and deluxe versions with an elliptical coated bulb shape and wattages of 50-400.
Features
Kolorlux Mercury lamps offer white light with good color rendering (40-53 Ra). You can depend on these lamps for long term reliability and their modest to low operating costs. Mercury lamps provide intense lighting for a wide range of applications.
Application areas
Streetlighting Amenityareas Security Parkinglots&garages Areafloodlighting Warehousing Industrialunits
Basic data
Product Code Nominal Wattage [W] Rated Wattage [W] Volts [V] Cap Product Descripton Nominal Lumen [lm] 1800 3800 3800 6300 6300 13000 22500 1800 3800 6500 13800 24400 Rated Lumen [lm] 2010 3990 4070 6620 6620 13620 25000 1880 3930 6520 13990 25600 Rated Lamp Efficacy [lm/W] 39 48 49 51 51 54 62 36 48 51 56 64 Mercury Content [mg] 9.0 13.0 13.0 21.0 21.0 41.0 65.0 9.0 13.0 21.0 41.0 65.0 Rated Average Life [hr] 16000 20000 20000 20000 20000 20000 20000 16000 20000 20000 20000 20000 CCT [K] Color Ambient Rendering Temp. Index [Ra] [C] 40 45 45 45 45 45 40 52 53 53 45 47 25 25 25 25 25 25 25 25 25 25 25 25
Kolorlux Mercury Standard 74171 50 52 74172 74173 73736 77071 73737 74174 80 80 125 125 250 400 82 82 129 129 251 401
95 115 115 125 125 130 135 95 115 125 130 135
E27 E27 B22 E27 B22 E40 E40 E27 E27 E27 E40 E40
H50 E27 H80 E27 H80 B22 H125 E27 H125 B22 H250 E40 H400 E40 H50 DX E27 H80 DX E27 H125 NDX E27 H250 NDX E40 H400 DX E40
4000 4000 4000 4000 4000 4000 4000 3700 3600 3500 3400 3400
Kolorlux Mercury Deluxe 77055 50 52 77056 77057 77058 77061 80 125 250 400 83 127 250 401
Dimensions
B
Watts A Length [mm] B Diameter [mm] 55 70 75 90 120 55 70 75 90 120 Cap Bulb Weight [g] 53 63 83 160 230 53 63 83 160 230 Operating Postition Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Minimum Starting Temperature [C] -18C -18C -18C -18C -18C -18C -18C -18C -18C -18C
Kolorlux Mercury Standard 50 130 80 125 250 400 156 170 227 292
E27 E27 E27 E40 E40 E27 E27 E27 E40 E40
Soft Soft Soft Hard Hard Soft Soft Soft Hard Hard
Kolorlux Mercury Deluxe 50 130 80 125 250 400 156 170 227 292
Kolorlux 80-400W
75%
75%
% of initial
50%
% of initial
50%
25%
25%
0%
12
16
0%
12
16
20
Kolorlux Deluxe
Relative intensity
75% 50% 50% 25% 0% 380 430 480 530 580 630 680 730
Relative intensity
75% 50% 50% 25% 0% 380 430 480 530 580 630 680 730
Wavelength [nm]
Wavelength [nm]
Photometric data
Watts 100 Hours Lumens Colour Temperature [K] 4,000 4,000 4,000 4,000 4,000 3,700 3,600 3,500 3,400 3,400 CRI [Ra] DIN5035 Classification 3 3 3 3 3 3 3 3 3 3 Kolorlux Mercury Standard 50 1,800 80 3,800 125 6,300 250 13,000 400 22,500 Kolorlux Mercury Deluxe 50 1,800 80 3,800 125 6,500 250 13,800 400 24,400
45 45 45 45 40 53 53 53 50 47
Electrical data
Dataisbasedonanominallampoperatingonanominalchoke(reactor)ballastwithpowerfactorcorrection.Supplypoweris based on a typical commercially available ballast.
Watts 50 80 125 250 400
* +/- 10V
Run-up characteristics
% change from nominal
Time for the light output to reach 90% of the final value is determined by supply voltage and ballast design. Typical values are:
Watts Run-up [mins] 50 6 80 5 125 5 250 5 400 5
100
200
300
400
500
600
Supply voltage
Lamps are suitable for supplies in the range 220V to 250V50/60Hzforappropriatelyratedserieschoke(reactor) ballasts. Supplies outside this range require a transformer (conventional,highreactanceorCWA)toensurecorrectlamp operation. Lamps start and operate at 10% below the rated supply voltage when the correct control gear is used. However in order to maximise lamp survival, lumen maintenance and colour uniformity the supply voltage and ballast design voltage should be within 3%. Supply variations of 5% are permissible for short periods only. Effect of supply voltage variation
35 30 25
20 15 10 5 0 -5 Lamp voltage Lamp current Lamp wattage Lamp lumens -10 -15 -20 -25 -30 -35 -10 -8 -6 -4 -2 0 2 4 6 8 10
Control gear
To achieve correct lamp starting, performance and life, it is important that lamp and control gear are compatible and suitably rated for the supply voltage at the luminaire.
Ballasts
LampsarefullycompatiblewithballastsmanufacturedforhighpressuremercurylampstoIEC60188.Ballastsshouldcomply withspecificationsIEC60262.
www.gelighting.com/eu
andGeneralElectricarebothregisteredtrademarks oftheGeneralElectricCompany
GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. Kolorlux Data Sheet October 2011