Sei sulla pagina 1di 2

High Performance 8028 Architectural Fabric

8028 Architectural
Base Fabric Type Base Fabric Weight (nominal) Finished Coated Weight ASTM D751 Tongue Tear ASTM D751 Trapezoid Tear ASTM D4533 Grab Tensile ASTM D751 Strip Tensile ASTM D751 Procedure B Adhesion ASTM D751 Dielectric Weld Hydrostatic Resistance ASTM D751 Procedure A Dead Load MIL-T-52983E (modified) Para.4.5.2.19 Low Temperature
ASTM D2136 1/8" mandrel, 4 hr

Standard
Polyester 7.5 oz/yd2 28 oz/yd2 +2/-1 oz/yd2
8"x10" sample @ 12 in/min.

Metric
Polyester 254 g/m2 949 g/m2 +70/-35 g/m2
20.3 cm x 25.4 cm sample @ 30.5 cm/min.

275/275 lbf 85/85 lbf 700/700 lbf 515/515 lbf/in 10 lbf/in 500 psi 2 in seam, 4 hr, 1 in strip 266 lbf @ room temp. 133 lbf @ 160 F Pass -40 F Pass -67 F

1223/1223 N 378/378 N 3115/3115 N 458/458 daN/5 cm 9 daN/5 cm 3.45 MPa 5 cm seam, 4 hr, 2.5 cm strip 1183 N @ room temp. 591 N @ 71C Pass -40 C Pass -55 C

LTC LTA

Flame Resistance

Meets California fire marshal requirements, UL214, NFPA 701, and FTMS 191 method 5903 - 2 second flameout ASTM E84 - flame spread index <25, smoke development rating <450

A RC H I T E C T U R A L FA B R I C S P E C I F I C AT I O N S
1000 VENTURE BLVD. WOOSTER, OHIO 44691 USA, U.S. Toll-Free: Phone 800-927-8578, Fax 800-649-2737 Phone 330-262-1111, Fax 330-263-6950 www.architecturalfabrics.com Email: afinfo@seamancorp.com 2001 Seaman Corporation

High Performance 8028 Architectural Fabric

Biaxial Stretch Test


8.00 7.00 6.00 % Stretch 5.00 4.00 3.00 2.00 1.00 0.00 0
1.09 1.74 2.24

WARP AND FILL LOADED AT 1:1 RATIO


6.22

FILL
3.62

5.08 4.23 2.78

0.48
15

0.93
30
Load, lbf/in

1.28
45

2.17
60

WARP

75

90

8.00 7.00 6.00 % Stretch 5.00 4.00 3.00 2.00 1.00 0.00 0

WARP AND FILL LOADED AT 1:2 RATIO

6.94

FILL
3.99

1.48

0.26
15

0.78
30
Load, lbf/in

45

1.04

WARP

60

75

90

8.00 7.00 6.00 % Stretch 5.00 4.00 3.00

WARP AND FILL LOADED AT 2:1 RATIO

FILL

5.56

2.43

2.00 1.00 0.00 0 15


1.22

2.69
WARP

1.65

1.56
Load, lbf/in

30

45

60

75

90

Revised August 2001

We believe this information is the best currently available on the subject. We offer it as a suggestion in any appropriate experimentation you may care to undertake. It is subject to revision as additional knowledge and experience are gained. We make no guarantee of the results and assume no obligation or liability whatsoever in connection with this information. In case of conflict between standard and metric specifications, standard shall apply.