Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 6 Air-Cooled Water Chillers
The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval.
Trane 1151 Keller Road Orlando, FL 32810-5924 Phone: (407)660-1111 Fax: (407)660-0303
Table Of Contents Product Summary.............................................................................. Error! Bookmark not defined. Air-Cooled Water Chillers (Large Tonnage) (Items A1 - A3)
Tag Data ...................................................................................................Error! Bookmark not defined. Product Data .............................................................................................Error! Bookmark not defined. Performance Data .....................................................................................Error! Bookmark not defined. Mechanical Specifications .........................................................................Error! Bookmark not defined. Unit Dimensions ........................................................................................Error! Bookmark not defined. Weight, Clearance & Rigging Diagram......................................................Error! Bookmark not defined. Field Wiring ...............................................................................................Error! Bookmark not defined.
Tag Data - Air-Cooled Water Chillers (Qty: 6) Item Tag(s) Qty Description A1 CGAF-C25 1 25 Ton Packaged Air-Cooled Chiller A2 CGAF-C50 2 50 Ton Packaged Air-Cooled Chiller A3 CGAF-C60 3 60 Ton Packaged Air-Cooled Chiller Product Data - Air-Cooled Water Chillers All Units 200 Volt 60 Hertz 3 Phase 40 to 50 degree F Water Setpoint UL/ CSA Approval Unit Spring Isolators (Fld) Unit Mounted Terminal Block Trane Communications Interface Module (TCI) R-407C
Page 3 of 17
Performance Data - Air-Cooled Water Chillers Tags CGAF-C25 Total cooling capacity (tons) 23.32 Ent evaporator temp (F) 54.00 Lvg evaporator temp (F) 44.00 Ambient temperature (F) 95.00 Evaporator fouling factor (hr-sq ft-deg F/Btu) 0.00001 Evaporator flow rate (gpm) 55.79 Saturated suction temp (F) 37.23 Cooling fluid PD (ft H2O) 6.15 Compressor power (kW) 25.92 Fan power (kW) 2.70 System power (kW) 28.62 EER @ ARI (EER) 9.8 COP @ ARI (COP) 2.80 IPLV @ ARI (IPLV) 14.6 Min circuit ampacity (A) 124.00 Max fuse size (A) 175.00 Recommended dual element (A) 150.00 Circuit 1 compressor 1 LRA (A) 269.00 Circuit 1 compressor 1 RLA (A) 39.30 Circuit 1 compressor 2 LRA (A) 409.00 Circuit 1 compressor 2 RLA (A) 56.90 Circuit 2 compressor 1 LRA (A) 0.00 Circuit 2 compressor 1 RLA (A) 0.00 Circuit 2 compressor 2 LRA (A) 0.00 Circuit 2 compressor 2 RLA (A) 0.00 Fan quantity (Each) 3.00 FLA per fan (A) 4.10 Part load step 1 (%) 40.00 Ambient at step 1 (F) 59.00 Capacity at step 1 (tons) 12.22 Unit power at step 1 (kW) 8.26 EER @ ARI at step 1 (EER) 15.3 Part load step 2 (%) 60.00 Ambient at step 2 (F) 71.00 Capacity at step 2 (tons) 16.89 Unit power at step 2 (kW) 13.48 EER @ ARI at step 2 (EER) 13.8 Part load step 3 (%) Ambient at step 3 (F) Capacity at step 3 (tons) Unit power at step 3 (kW) EER @ ARI at step 3 (EER) Outdoor - 63 Hz (dB) 96 Outdoor - 125 Hz (dB) 91 Outdoor - 250 Hz (dB) 92 Outdoor - 500 Hz (dB) 91 Outdoor - 1 kHz (dB) 88 Outdoor - 2 kHz (dB) 87 Outdoor - 4 kHz (dB) 84 Outdoor - 8 kHz (dB) 82 A weighted sound power (dBA) 94 A weighted sound pressure (dBA) 67 Min operating weight (lb) 2085.0 Max operating weight (lb) 2370.0
CGAF-C50 42.77 54.00 44.00 95.00 0.00001 102.32 37.69 7.42 46.98 5.40 52.38 9.7 2.80 14.5 224.00 250.00 250.00 409.00 55.50 269.00 35.50 409.00 55.50 269.00 35.50 6.00 4.10 30.00 55.00 14.57 10.70 17.0 60.00 71.00 31.17 24.87 13.5 80.00 83.00 37.73 37.42 11.3 97 92 92 93 89 89 87 85 96 69 3900.0 4435.0
CGAF-C60 54.65 54.00 44.00 95.00 0.00001 130.75 38.24 6.00 62.22 5.40 67.62 9.7 2.80 15.0 270.00 300.00 300.00 409.00 56.90 409.00 56.90 409.00 56.90 409.00 56.90 6.00 4.10 25.00 55.00 15.93 11.30 18.3 50.00 65.00 35.08 25.17 15.2 75.00 80.00 46.16 43.41 11.9 97 92 92 94 91 89 87 85 97 70 4885.0 5820.0
Page 4 of 17
Mechanical Specifications - Air-Cooled Water Chillers (Large Tonnage) Item: A1 - A3 Qty: 6 Tag(s): CGAF-C25, CGAF-C50, CGAF-C60 General All chillers are factory run-tested to confirm proper operation. Units are checked on computer based test stand at typical ambient and water conditions and control operation is monitored. Units ship with a full operating charge of refrigerant and oil. Units are constructed of 14-gauge welded galvanized steel frame with 14 and 16-gauge galvanized steel panels and access doors. Unit surface is phosphatized and finished with an air-dry paint. This air-dry paint finish is durable enough to withstand a 1000-consecutive-hour salt spray application in accordance with standard ASTM B117. A flow switch is included as ship-with item to be field installed at the outlet of the evaporator. The flow switch is required as a safety interlock to prevent operation of unit without evaporator flow. General A strainer (with installation hardware) is included as a ship-with item to be field installed at the inlet of the evaporator. The strainer is required to prevent collection of particles within the evaporator. Strainer is field installed to facilitate ease of installation. Compressor Trane 3-D Scroll compressors have simple mechanical design with only three (3) major moving parts. Scroll type compression provides inherently low vibration. 3-D compliance provides a completely enclosed compression chamber which leads to increased efficiency. Exhaustive testing on the 3D Scroll, including start up with the shell full of liquid, has proven that slugging does not fail involutes. Direct-drive, 3600 rpm, suction gas-cooled hermetic motor. Trane 3D Scroll compressor includes centrifugal oil pump, oil level sightglass and oil charging valve. Evaporator The evaporator shall be braze plate construction with a waterside working pressure of 300 PSIG and a refrigerant side of working pressure of 225. Etched foil heaters protect the evaporator to ambient of -20 degrees F. Condenser Fans Direct-drive vertical discharge condenser fans are statically and dynamically balanced. Three phase thermal overload protected with permanently lubricated ball bearings. Controls Compressor contactors and unit controls are in a weather tight enclosure with knockouts for field installed wiring. The chiller unit utilizes a DDC microprocessor control system which is suitable for comfort and process cooling applications. The control system is factory installed in the main control panel with the necessary internal controls and run tested. Terminal blocks for field power wiring connections are standard. Units provide a location for a non-fused disconnect switch with an external handle for safety. Unit mounted microprocessor controls provide compressor antishort cycle protection. The unit is equipped with a Human Interface Panel with a 16 key keypad, a 2 line by 40 character English display to provide the operator with full adjustment and display of control data function. The unit controls can be used as a stand-alone controller or as part of a building management system. The display can be read and adjusted without opening any unit panels. Decorative Grilles Decorative grilles provide protection from exterior damage to coil surface and other interior unit components. Grilles are factory mounted louvered, galvanized steel panels finished with an air dry paint. Grilles cover all air accessible ends of the unit. Refrigerant Circuits with 2-Stage Capacity Modulation for 20 - 30 Ton Units The unit has a single refrigeration circuit with two (2) compressors manifolded together utilizing a passive oil system. The refrigerant circuit includes an liquid line solenoid valve, filter drier, sight glass with moisture indicator, thermostatic expansion valve and service valves (liquid and discharge). Capacity modulation is accomplished by turning compressors on and off. The unit has two capacity stages. The standard leaving chilled water temperature range is 40 to 50 F [4.5 to 10 C]. Refrigerant Circuits with 4-Stage Capacity Modulation for 40 - 60 Ton Units The unit has dual refrigeration circuits. Each circuit has two (2) compressors manifolded together utilizing a passive oil system. Each refrigerant circuit includes an liquid line solenoid valve, filter drier, sightglass with moisture indicator,thermostatic expansion valve and service valves (liquid and discharge). Capacity modulation is accomplished by turning compressors on and off. The unit has four capacity stages. The standard leaving chilled
FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 5 of 17
water temperature range is 40 to 50 F [4.5 to 10 C]. Trane Communication Interface Module ( TCI ) The TCI provides interface to Trane's Integrated Comfort system ( ICS ), which allows control and monitoring of the unit by Tracer building management system. Spring Isolators Spring isolators are available for field installation under the unit frame. Condenser Coils with Aluminum Fins Air-cooled condenser coils have configured aluminum fins mechanically bonded to seamless copper tubing and integral subcooling circuits. Condenser coils are factory leak tested under water with 425 psig [2930.4 kPa] air pressure.
Page 6 of 17
Unit Dimensions - Air-Cooled Water Chillers (Large Tonnage) Item: A1 Qty: 1 Tag(s): CGAF-C25
3 1/4" 83mm 3'-1 3/8" 949mm 3'-3 5/8" 1006mm 2'-11" 889mm 2'-9" 838mm 5 7/8" 149mm 7'-4 " 1/4 1 3/32" (1X) HEAT TAPE POWER 28mm 8" 3" CONDUIT MAIN POWER 76mm 9 3/4" 248mm 7 1/8" 181mm 3/4" 19mm DIA. X 4 MTG HOLES 203mm 6'- "1/8 1832mm 8'-0" 2438mm MINIMUM CLEARANCE 2242mm
3 5/8" 92mm
DETAIL "A"
NO OBSTRUCTIONS AIR FLOW OPTIONAL DAMPER 2 3/4" 70mm 1'-1 1/2" 343mm
3 1 1/4" 32mm
TOP VIEW
CONTROL PANEL
6 1/8 " 3'-2" 965mm 156mm 6'-1 3/8" 1864mm 5'-8" 1727mm COMP 2'-3 1/4" 692mm 4 3/8 " 111mm
3 5/8" DIA. 92mm LINE VOLTAGE 1 1/4" X 4 1/2" 32mm X 114mm CONTROL CONN. 1'-6" 457mm SLOT
11 1/2" 292mm
5 1/8" 130mm
6'-6" 1981mm
2 1/2" 64mm
FRONT VIEW
9" 229mm
Page 7 of 17
Unit Dimensions - Air-Cooled Water Chillers (Large Tonnage) Item: A2 Qty: 2 Tag(s): CGAF-C50
3 1/4" 83mm 3'-1 3/8" 949mm 3'-3 5/8" 1006mm 2'-11" 889mm 2'-9" 838mm 5 7/8" 149mm 1 3/32" (1X) HEAT TAPE POWER 28mm 3" CONDUIT MAIN POWER 76mm 9 3/4" 248mm 7 1/8" 181mm CONNECTIONS BOTTOM SEE DETAIL "A" 2 8 1/8" 206mm 4'-0 7/8" 1241mm
3 5/8" 92mm
DETAIL "A"
OPTIONAL DAMPER
TOP VIEW
5" 127mm
FRONT VIEW
9-1/2" 241mm
5' 1528mm
1' 1" 336mm
Page 8 of 17
Unit Dimensions - Air-Cooled Water Chillers (Large Tonnage) Item: A3 Qty: 3 Tag(s): CGAF-C60
3 1/4" 83mm 3'-1 3/8" 949mm 3'-3 5/8" 1006mm 2'-11" 889mm 2'-9" 838mm 5 7/8" 149mm 1 3/32" (1X) HEAT TAPE POWER 28mm 3" CONDUIT MAIN POWER 76mm 9 3/4" 248mm 7 1/8" 181mm CONNECTIONS BOTTOM SEE DETAIL "A" 2 8 1/8" 206mm 4'-0 7/8" 1241mm 9'-5 7/8" 2892mm 4'-0 7/8" 1241mm
DETAIL "A"
3'-5 3/4" 1060mm NO OBSTRUCTIONS AIR FLOW DOOR SWING 180
OPTIONAL DAMPER 1 2 3/4" 70mm 3 5 1 1/4" 32mm 8'-0" 2438mm MINIMUM CLEARANCE
TOP VIEW
CONTROL PANEL 4'-6" 1371mm 6'-6 3/8" 1991mm 6'-1" 1854mm 3 5/8" DIA 92mm LINE VOLTAGE
5 1/4" 133mm
3" Grooved Pipe Connection Water Inlet COMP 3" Grooved Pipe Connection Water Outlet
7" 178mm
5" 127mm
FRONT VIEW
9-1/2" 241mm
5' 1528mm
1' 1" 336mm
Page 9 of 17
Weight, Clearance & Rigging Diagram - Air-Cooled Water Chillers (Large Tonnage) Item: A1 Qty: 1 Tag(s): CGAF-C25
WARNING!!!
TO PREVENT INJURY OR DEATH AND POSSIBLE EQUIPMENT DAMAGE, DO NOT USE CHAIN (CABLES) OR SLINGS EXCEPT AS SHOWN AND USE CABLES STRONG ENOUGH TO SUPPORT UNIT WEIGHT. TEST LIFT UNIT TO ENSURE PROPER BALANCE AND RIGGING.
UNIT RIGGING
8 1/16"
2
72 1/4"
3
57 1/2"
UNIT CLEARANCE
49 1/16"
FRONT OF UNIT
1 1/4"
NOTES:
1. OPERATING WEIGHT INCLUDES REFRIGERANT, OIL AND WATER. 2. SHIPPING WEIGHT INCLUDES REFRIGERANT AND OIL CHARGES. 3. IF THE UNIT IS INSTALLED IN A WELL, THE DEPTH OF THE WELL MUST NOT EXCEED THE HEIGHT OF THE UNIT. THE TOP OF THE UNIT MUST HAVE UNRESTRICTED AIRFLOW.
Page 10 of 17
Weight, Clearance & Rigging Diagram - Air-Cooled Water Chillers (Large Tonnage) Item: A2 Qty: 2 Tag(s): CGAF-C50
WARNING!!!
TO PREVENT INJURY OR DEATH AND POSSIBLE EQUIPMENT DAMAGE, DO NOT USE CHAIN (CABLES) OR SLINGS EXCEPT AS SHOWN AND USE CABLES STRONG ENOUGH TO SUPPORT UNIT WEIGHT. TEST LIFT UNIT TO ENSURE PROPER BALANCE AND RIGGING.
CONTROL PANEL
UNIT RIGGING
CLEARANCE 96"
UNIT CLEARANCE
85 5/8"
58"
FRONT OF UNIT
5
1 5/16" 46"
NOTES:
1. OPERATING WEIGHT INCLUDES REFRIGERANT, OIL AND WATER. 2. SHIPPING WEIGHT INCLUDES REFRIGERANT AND OIL CHARGES. 3. IF THE UNIT IS INSTALLED IN A WELL, THE DEPTH OF THE WELL MUST NOT EXCEED THE HEIGHT OF THE UNIT. THE TOP OF THE UNIT MUST HAVE UNRESTRICTED AIRFLOW.
Page 11 of 17
Weight, Clearance & Rigging Diagram - Air-Cooled Water Chillers (Large Tonnage) Item: A3 Qty: 3 Tag(s): CGAF-C60
WARNING!!!
TO PREVENT INJURY OR DEATH AND POSSIBLE EQUIPMENT DAMAGE, DO NOT USE CHAIN (CABLES) OR SLINGS EXCEPT AS SHOWN AND USE CABLES STRONG ENOUGH TO SUPPORT UNIT WEIGHT. TEST LIFT UNIT TO ENSURE PROPER BALANCE AND RIGGING.
CONTROL PANEL
UNIT RIGGING
CLEARANCE 96"
UNIT CLEARANCE
85 5/8"
58"
FRONT OF UNIT
5
1 5/16" 47"
NOTES:
1. OPERATING WEIGHT INCLUDES REFRIGERANT, OIL AND WATER. 2. SHIPPING WEIGHT INCLUDES REFRIGERANT AND OIL CHARGES. 3. IF THE UNIT IS INSTALLED IN A WELL, THE DEPTH OF THE WELL MUST NOT EXCEED THE HEIGHT OF THE UNIT. THE TOP OF THE UNIT MUST HAVE UNRESTRICTED AIRFLOW.
Page 12 of 17
Field Wiring - Air-Cooled Water Chillers (Large Tonnage) Item: A1 - A3 Qty: 6 Tag(s): CGAF-C25, CGAF-C50, CGAF-C60
WARNING
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING.
FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.
AVERTISSEMENT
VOLTAGE HASARDEUX!
DECONNECTEZ TOUTES LES SOURCES ELECTRIQUES INCLUANT LES DISJONCTEURS SITUES A DISTANCE AVANT D'EFFECTUER L'ENTRETIEN.
FAUTE DE DECONNECTER LA SOURCE ELECTRIQUE AVANT D'EFFECTUER L'ENTRETIEN PEUT ENTRAINER DES BLESSURES CORPORELLES SEVERES OU LA MORT.
CAUTION
USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT.
Notes:
LOCATION
CONTROL PANEL FAN SECTION COMPRESSOR SECTION EXTERNAL FACTORY MTD DEVICE CUSTOMER OR FIELD PROVIDED SHIP W/FIELD INSTALLED DEVICE IMPORTANT! DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND START-UP PROCEDURE HAS BEEN COMPLETED
Connect to 24VAC Connect to 24VAC class 2 circuits only. class 2 circuits only.
ALARM OUTPUT
NC
COM
NO
NC
COM
NO
450
449
448
447
446
445
1TB5
1 2 3 4 5 6 7 8 9 10 11 445 446 447 448 449 450 495 496 497 498 499 500 12 501 13 502 14 503 15 533 16 534 17 537 18 538 19 20 21 22
Page 13 of 17
Field Wiring - Air-Cooled Water Chillers (Large Tonnage) Item: A1 - A3 Qty: 6 Tag(s): CGAF-C25, CGAF-C50, CGAF-C60
WARNING
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING.
FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.
AVERTISSEMENT
VOLTAGE HASARDEUX!
DECONNECTEZ TOUTES LES SOURCES ELECTRIQUES INCLUANT LES DISJONCTEURS SITUES A DISTANCE AVANT D'EFFECTUER L'ENTRETIEN.
FAUTE DE DECONNECTER LA SOURCE ELECTRIQUE AVANT D'EFFECTUER L'ENTRETIEN PEUT ENTRAINER DES BLESSURES CORPORELLES SEVERES OU LA MORT.
CAUTION
USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT.
LOCATION
CONTROL PANEL FAN SECTION COMPRESSOR SECTION EXTERNAL FACTORY MTD DEVICE CUSTOMER OR FIELD PROVIDED SHIP W/FIELD INSTALLED DEVICE
IMPORTANT! DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND START-UP PROCEDURE HAS BEEN COMPLETED
424
425
1TB4
1 410 424 425 12 13 2 411 3 4 5 ICS CONTROLLED (CONNECT TO 24 VOLT CLASS 2 CIRCUIT ONLY) 414
437
438
438
434
431
435
Remove jumper between 1tb4-16 & 17 when required, Contacts rated 12mA @ 24VDC minimum. Remove jumper between 1tb4-18 & 19 when required, Contacts rated 12mA @ 24VDC minimum.
5S67 EXTERNAL AUTO/STOP SWITCH 5S71 EMERGENCY STOP SWITCH
Notes:
2. Phantom lines indicate alternate circuitry or available sales options.
Page 14 of 17
Field Wiring - Air-Cooled Water Chillers (Large Tonnage) Item: A1 - A3 Qty: 6 Tag(s): CGAF-C25, CGAF-C50, CGAF-C60
WARNING
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING.
FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.
AVERTISSEMENT
VOLTAGE HASARDEUX!
DECONNECTEZ TOUTES LES SOURCES ELECTRIQUES INCLUANT LES DISJONCTEURS SITUES A DISTANCE AVANT D'EFFECTUER L'ENTRETIEN.
FAUTE DE DECONNECTER LA SOURCE ELECTRIQUE AVANT D'EFFECTUER L'ENTRETIEN PEUT ENTRAINER DES BLESSURES CORPORELLES SEVERES OU LA MORT. CUSTOMER CONNECTION WIRE RANGE
CAUTION
USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT.
NOTES
A. BLOCK SIZE & DISCONNECT SIZE ARE CALCULATED BY SELECTING THE SIZE GREATER THAN OR EQUAL TO 1.15 X (SUM OF UNIT LOADS). SEE UNIT LITERATURE FOR UNIT LOAD VALUES.
UNITS WITH MAIN POWER TERMINAL BLOCK (ALL VOLTAGES) BLOCK SIZE 335 AMP WIRE QTY. 1 CONNECTOR WIRE RANGE (1) #6 - 350 MCM
IMPORTANT! DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND START-UP PROCEDURE HAS BEEN COMPLETED
AREA
1
LOCATION
CONTROL PANEL
1TB6 1 5T1 5S1 2 5K1 5K1-OL 39 3 4 5 38 38 39 6 7 8 9 10 EQUIPMENT GROUND 1TB1 4HR1 - HEAT TAPE POWER WIRING 11 12
201
DEVICE DESIGNATION
5B1 5K1 5K86 5K89 5RT19 5S1 5S67 5S71 5T1 CHILLER PUMP MOTOR CHILLED SOL PUMP STARTER ICE BUILDING INITIATE DEMAND LIMIT RELAY ICE DEFINED TEMP. SENSOR FUSED DISCONNECT EXTERNAL AUTO STOP SWITCH EMERGENCY STOP CONTROL TRANSFORMER TO 4HR1 HEAT TAPE 200 L1
1TB12
Notes:
Page 15 of 17
Field Wiring - Air-Cooled Water Chillers (Large Tonnage) Item: A1 - A3 Qty: 6 Tag(s): CGAF-C25, CGAF-C50, CGAF-C60
WARNING
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING.
FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.
AVERTISSEMENT
VOLTAGE HASARDEUX!
DECONNECTEZ TOUTES LES SOURCES ELECTRIQUES INCLUANT LES DISJONCTEURS SITUES A DISTANCE AVANT D'EFFECTUER L'ENTRETIEN.
FAUTE DE DECONNECTER LA SOURCE ELECTRIQUE AVANT D'EFFECTUER L'ENTRETIEN PEUT ENTRAINER DES BLESSURES CORPORELLES SEVERES OU LA MORT.
CAUTION
USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT.
Notes:
LOCATION
CONTROL PANEL FAN SECTION COMPRESSOR SECTION EXTERNAL FACTORY MTD DEVICE CUSTOMER OR FIELD PROVIDED SHIP W/FIELD INSTALLED DEVICE IMPORTANT! DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND START-UP PROCEDURE HAS BEEN COMPLETED
Connect to 24VAC Connect to 24VAC class 2 circuits only. class 2 circuits only.
ALARM OUTPUT
NC
COM
NO
NC
COM
NO
450
449
448
447
446
445
1TB5
1 2 3 4 5 6 7 8 9 10 11 445 446 447 448 449 450 495 496 497 498 499 500 12 501 13 502 14 503 15 533 16 534 17 537 18 538 19 20 21 22
534
533
(-)
(+)
Page 16 of 17
Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - Air-Cooled Water Chillers (Large Tonnage) Item Tag(s) Qty Description A1 CGAF-C25 1 25 Ton Packaged Air-Cooled Chiller A2 CGAF-C50 2 50 Ton Packaged Air-Cooled Chiller A3 CGAF-C60 3 60 Ton Packaged Air-Cooled Chiller Field Installed Option Description Unit Spring Isolators
Page 17 of 17