BOUNDARY NOISE SURVEY REPORT


(Report no: bns/11/0303)
Date : 29 March 2011
th

Prepared for

ADVANCED MICRO DEVICES (SINGAPORE) PTE LTD


508, Chai Chee Lane, Singapore 469026

Attention : Mr. Alaudeen, Sheik

Consultant in Attendance: Dr. Tan Kok Yang,


BSc Bldg, MScBldgSc,(NUS),PhD(NE,Aust) Member, Society of Acoustics, Singapore Life Member, EESS (Acoustics)

Prepared by

ACOUSTICAL LABORATORY PTE LTD


140 Upper Bukit Timah Road, #03-05, Beauty World Plaza, Singapore 588176. Tel: (65) 6465 6212 Fax: (65) 6465 6223 Email: enquiry@noisecontrols.com Website: www. noisecontrols.com

ALL COPYRIGHTS RESERVED, 2011

Acoustical & Environmental Consultation, Training & Services

BOUNDARY NOISE SURVEY REPORT


REPORT NUMBER: DATE OF REPORT: SURVEYED ON: SURVEYED BY: CONSULTANT: bns/11/0303 29th March 2011 03/03/2011 05/03/2011 Dr. Tan Kok Yang, PhD (NE) (Acoustic Consultant) Tan Toh Liang, NMO (MOM aprvd) SURVEYED FOR:

ADVANCED MICRO DEVICES (SINGAPORE) PTE LTD


508,Chai Chee Lane, Singapore 469026 Attention: Mr. Alaudeen, Sheik

REMARKS: Boundary Noise Survey at your factory located at the above address.

Instrument Sound Level Meter Sound Level Meter Calibrator

Brand Castle Quest Rion

Model GA120 Prosound NC-73

Serial No. 038386 BJJ080020 10540513

Type I I I

Notes
The Sound Pressure Levels recorded are shown as L eq (5 min) or as in the specified periods as required by the above Regulations. The Regulations referred to in this report is the Environmental Protection and Management (Boundary Noise Limits for Factory Premises) Regulations 2008. The specified periods referred to in this report are those set out in the above Regulations. For clarification and further information, kindly contact ACOUSTICAL LABORATORY PTE LTD at Tel: 6465 6212. This report is issued under the conditions stated as below: 1. This is a Boundary Noise Survey Report and not a Certificate of Acoustic Quality. The significance of the report is subject to the comprehensiveness of the noise survey as required by the relevant regulations. This report does not constitute a recommendation for, or endorsement of the acoustical quality of the area/space surveyed. 2. ACOUSTICAL LABORATORY PTE LTD agrees to use reasonable diligence in the manner of performing the boundary noise survey but no warranties are given and none may be implied directly or indirectly relating to this report. Under no circumstances shall ACOUSTICAL LABORATORY PTE LTD be liable for any collateral, special or consequential damage. 3. This report must not be used in advertisements without the written consent of ACOUSTICAL LABORATORY PTE LTD.

BOUNDARY NOISE SURVEY REPORT

Page 2 of 8

TABLE OF CONTENTS

1. 2. 3. 4. 5. 6.

INTRODUCTION SAMPLING LOCATIONS SURVEY PROCEDURES RESULTS SUMMARY CONCLUSION

Page 4 Page 4 Page 5 Page 5 Page 8 Page 8

APPENDIX I: APPENDIX II: APPENDIX III: APPENDIX IV: APPENDIX V:

LOCATION PLAN MAXIMUM PERMISSIBLE NOISE LEVELS CHARTS NOISE DATA CALIBRATION CERTIFICATES

BOUNDARY NOISE SURVEY REPORT

Page 3 of 8

1.

INTRODUCTION
Preliminary Information

The boundary noise survey was carried out: for at ADVANCED MICRO DEVICES (SINGAPORE) PTE LTD 506 and 508 , Chai Chee Lane, Singapore 469026 3rd March 2011 to 5th March 2011 continuously over a period of 24 hours for each point (Total 4 points) and sampling method for six other points.

from

2.

SAMPLING LOCATION
Description of Monitoring Points (Please refer to Appendix I: Location Plan) (Residential Area: continuous 24 hrs monitoring) Point 1 : next to Block 506, facing residential area. Point 2 : next to Block 506, facing residential area. Point 3 : next to Block 508, facing residential area. Point 4 : next to Block 508, facing residential area and near to PIE

(Industrial Area - sampling only during the day time period) Point 5 to 7: next Block 508, facing PIE (Traffic Noise) Point 8 & 9: next to Block 508, facing JTC factories Point 10: next to Block 506 Guard Room

BOUNDARY NOISE SURVEY REPORT

Page 4 of 8

3.

SURVEY PROCEDURES

The survey was carried out in accordance with the procedures set out under Section 3 and Section 4 of the Environmental Protection and Management (Boundary Noise Limits for Factory Premises) Regulations 2008. The noise levels emitted from the premises were monitored according to the requirements of the Regulations, as follows: a) The equivalent continuous noise level over the specified periods in Part I of the First Schedule of the Regulations. The equivalent continuous noise level over 5 minutes in Part II of the First Schedule of the Regulations.

b)

Sound level meters used for the survey conformed to the requirements of the Regulations and were calibrated prior to use.

4.

RESULTS
Noise measurements were taken over the specified periods for all the monitoring points shown in Table 1 and Table 2.

Equivalent Continuous Sound Pressure Levels, or Leq(5min) were monitored and results plotted in Charts no1 to 4 , respectively.

BOUNDARY NOISE SURVEY REPORT

Page 5 of 8

4.1

NOISE LEVELS OVER SPECIFIED PERIODS


Table 1a
For Factory Premises Day Evening Night

0700hr-1900 hr Maximum Permitted Noise Level as in FIRST SCHEDULE (Commercial)

1900hr-2300hr

2300hr-0700hr

70

65

60

Monitoring Points 5 6 7 8 9 10
Notes

Measured Noise Levels, dB(A)


64.8 67.2 65.7 61.5 58.4 51.0 No data logged

Maximum permitted noise level (reckoned as the equivalent continuous noise level over the specified periods) in decibels(A) Environmental Protection and Management (Boundary Noise Limits for Factory Premises) Regulations 2008.

Comments: Noise levels monitored over the specified periods show the following results: Boundary noise levels found to be within the set limits for all Points during the day time period. Table 1b
For Residential Premises Day Evening Night

0700hr-1900 hr Maximum Permitted Noise Level as in FIRST SCHEDULE Part I (Residential)

1900hr-2300hr

2300hr-0700hr

65

60

55

Monitoring Points 1 2 3 4
Notes

Measured Noise Levels, dB(A)


57.0 62.3 56.3 59.1 50.0 57.4 54.8 55.0 47.9 55.0 52.9 53.4

Maximum permitted noise level (reckoned as the equivalent continuous noise level over the specified periods) in decibels(A)Environmental Protection and Management (Boundary Noise Limits for Factory Premises) Regulations 2008.

Comments: Noise levels monitored over the specified periods show the following results: Boundary noise levels found to be within the set limits for all Points/Time Periods at all the 4 monitoring points.

BOUNDARY NOISE SURVEY REPORT

Page 6 of 8

For Point 4 noise data exclude traffic from PIE (i.e. up to 6 dB(A)was deducted from the reading to arrive at the above results for these two points.

4.2

NOISE LEVEL OVER 5 MINUTES PERIODS (FOR A 24 HOURS PERIOD) Please refer to Appendix III: Charts
Table 2a Day For Residential Premises 0700hr-1900 hr Maximum Permitted Noise Level as in FIRST SCHEDULE (Residential) Monitoring Points Points 1,2 3 and 4
Note:

Evening

Night

1900hr-2300hr 65

2300hr-0700hr 60

70

< 70 (within limit)

Measured Noise Levels, dB(A) < 65 < 60 (within limit) (within limit)

Maximum Permitted Noise Level (reckoned as the equivalent continuous noise level over 5 minutes period) in dB(A) Environmental Protection and Management (Boundary Noise Limits for Factory Premises) Regulations 2008.

Comments Noise levels monitored over the 5 minutes periods for the above points show the following results: Boundary noise levels found to be within the set limits for all Points/Time Periods.

BOUNDARY NOISE SURVEY REPORT

Page 7 of 8

5.

SUMMARY NOISE LEVELS FOR SPECIFIED PERIODS Boundary noise levels at all the monitoring points for all the 3 specified periods were found to be within the limits set out in the Regulations for noise level due to the Source. For Points 4 to 7, noise from PIE was excluded from the results to reflect the ambient noise levels. NOISE LEVELS OVER 5 MINUTES PERIODS 5 minutes Leq Noise levels for all the 3 specified periods were found to be within the limits set out in the Regulations at all the monitoring points.

6.

CONCLUSION The boundary noise survey for M/s Advanced Micro Devices (S) Pte Ltd was carried out as described in this report and the results presented herein. Boundary noise limits are found to be within the limits set out by the Environmental Protection and Management (Boundary Noise Limits for Factory Premises) Regulations 2008 at all the ten (10) noise monitoring points around the premises.

kytan
Dr. Tan Kok Yang
PRINCIPAL CONSULTANT

29 March 2011
-end of report-

th

Acknowledgement: Acoustical Laboratory Pte Ltd would like to thank Mr. Alaudeen, Sheik and Mr. Kumar of AMD for their support and assistance during the duration of the boundary noise survey.

BOUNDARY NOISE SURVEY REPORT